Study on Condition Pre-warning Method of Power Transformer based on Load Time Series Model

被引:0
|
作者
Wang Hongbin [1 ]
Du Shuangyu [1 ]
Dai Jianzhuo [2 ]
Ren Ming
Dong Ming
机构
[1] Guangdong Power Grid Corp, Elect Power Res Inst, Guangzhou 510080, Guangdong, Peoples R China
[2] Xi An Jiao Tong Univ, State Key Lab Elect Insulat Power Equipment, Xian 710049, Peoples R China
关键词
power transformer; condition pre-warming; load time series; condition monitoring;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Power transformer is one of key equipment in power system and its normal operation guarantees reliability and safety of power transmission. In order to keep power transformer in good condition, regular inspection and maintenance is needed after equipment put into service. Various preventive test, on-line monitoring and portable test are must, but condition evaluation and fault diagnosis for power transformer still is kind of art, which normally depend on standards, guideline or accumulated experiences on-site. In this paper, insulating condition is evaluated by equipment's operating load, and time series model is established to analyze load characteristics. After outlier value extraction and data reduction, two typical load growth modes have been proposed. Results show that the proposed load time series model could be applied to equipment operating status trend analysis. This approach provides a new idea for power transformer insulation pre-warning by making use of power transformer load characteristic analysis.
引用
收藏
页码:222 / 226
页数:5
相关论文
共 50 条
  • [1] Research and application of food safety Pre-warning model based on AHP and time series Association
    Guo, Shilong
    Wang, Yong
    [J]. PROCEEDINGS OF THE 2016 4TH INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS AND COMPUTING TECHNOLOGY, 2016, 60 : 1550 - 1553
  • [2] Distribution transformer mid-term heavy load and overload pre-warning based on logistic regression
    Li, Ming
    Zhou, Qin
    Yang, Zhihui
    [J]. 2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [3] A Pre-Warning Method of Contamination Flashover Based on the I,eakage Current of Insulators in Dry Condition
    Jin, Lijun
    Xu, Zhiyuan
    Zhang, Shengmeng
    [J]. 2017 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM), VOLS 1 & 2, 2017, : 757 - 760
  • [4] Research of Pre-warning and Diagnosis for Transformer Based on On-line Monitoring Devices
    Guo, Rongping
    Yan, Xiaohu
    Peng, Qian
    Cao, Yongxing
    Zhang, Hailong
    [J]. 2013 IEEE TENCON SPRING CONFERENCE, 2013, : 381 - 385
  • [5] Study on the evaluation and pre-warning of social crisis based on uncertainty measure model
    Li, Baizhou
    Liu, Peng
    [J]. ISCRAM CHINA 2007: PROCEEDINGS OF THE SECOND INTERNATIONAL WORKSHOP ON INFORMATION SYSTEMS FOR CRISIS RESPONSE AND MANAGEMENT, 2007, : 487 - 493
  • [6] Research on the Public Opinion Pre-warning Based on the Logistic Model
    Yin, Fulian
    Zhang, Beibei
    Su, Ge
    Zhang, Ruizhe
    [J]. PROCEEDINGS OF 2017 8TH IEEE INTERNATIONAL CONFERENCE ON SOFTWARE ENGINEERING AND SERVICE SCIENCE (ICSESS 2017), 2017, : 381 - 385
  • [7] A temperature-based fault pre-warning method for the dry-type transformer in the offshore oil platform
    Sun, Yuanyuan
    Hua, Yue
    Wang, Erdong
    Li, Na
    Ma, Shuo
    Zhang, Lina
    Hu, Yiru
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 123
  • [8] Research on Financial Pre-warning of Wind Power Enterprises Based on Cash
    Liu, Shu-Liang
    Zhang, Bing-Yu
    [J]. 2016 INTERNATIONAL CONFERENCE ON MANAGEMENT, ECONOMICS AND SOCIAL DEVELOPMENT (ICMESD 2016), 2016, : 71 - 76
  • [9] Study on Financial Risk Pre-warning of Combined Heat and Power Corporate
    Xiao Zhen-hong
    [J]. 2008 4TH INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATIONS, NETWORKING AND MOBILE COMPUTING, VOLS 1-31, 2008, : 10572 - 10575
  • [10] Target location method for pipeline pre-warning system based on HHT and time difference of arrival
    Sun, Jiedi
    Wen, Jiangtao
    [J]. MEASUREMENT, 2013, 46 (08) : 2716 - 2725