Ventilation strategies and indoor air quality in Swedish primary school classrooms

被引:20
|
作者
Cabovska, Blanka [1 ]
Beko, Gabriel [2 ,3 ]
Teli, Despoina [1 ]
Ekberg, Lars [1 ,4 ]
Dalenback, Jan-Olof [1 ]
Wargocki, Pawel [2 ]
Psomas, Theofanis [1 ]
Langer, Sarka [1 ,5 ]
机构
[1] Chalmers Univ Technol, Dept Architecture & Civil Engn, Div Bldg Serv Engn, SE-41296 Gothenburg, Sweden
[2] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, Dept Environm & Resource Engn, DK-2800 Lyngby, Denmark
[3] Ajman Univ, Coll Architecture Art & Design, Dept Architecture, POB 346, Ajman, U Arab Emirates
[4] CIT Energy Management AB, SE-41288 Gothenburg, Sweden
[5] IVL Swedish Environm Res Inst, Environm Chem, SE-40014 Gothenburg, Sweden
基金
瑞典研究理事会;
关键词
Indoor air pollutants; Thermal environment; Indoor environmental index; VOLATILE ORGANIC-COMPOUNDS; CARBON-DIOXIDE; ENVIRONMENTAL-QUALITY; THERMAL CONDITIONS; HEALTH; ASSOCIATION; PERFORMANCE; POLLUTANTS; BUILDINGS; SYMPTOMS;
D O I
10.1016/j.buildenv.2022.109744
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The present study aimed at investigating the effects of ventilation strategies on indoor air quality (IAQ) in schools. Measurements of thermal environment and IAQ were performed over 5 school days in 45 primary school classrooms in Gothenburg, Sweden, grouped into three categories according to their ventilation system: category A) natural or exhaust ventilation, or automated window opening; category B) balanced mechanical ventilation systems with constant air volume (CAV) and category C) balanced mechanical ventilation systems with variable air volume (VAV). The classrooms performed equally well with respect to temperature and relative humidity regardless of the ventilation system. The concentrations of the air pollutants in all classrooms were generally below the respective guideline values. The concentrations of CO2, formaldehyde, PM10, and PM2.5 were lower in the B and C category classrooms with higher ventilation rates than in the A category classrooms. Indoor Air Pollution Index integrating concentrations of multiple pollutants was significantly higher the A category class-rooms, reflecting poorer IAQ. Majority of the classrooms had lower ventilation rates than the Swedish ventilation requirements. The periodically reduced ventilation rates in the classrooms with VAV systems did not lead to substantial increase in the measured indoor pollutant concentrations.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Ventilation strategies and children's perception of the indoor environment in Swedish primary school classrooms
    Vasquez, Natalia Giraldo
    Beko, Gabriel
    Wargocki, Pawel
    Cabovska, Blanka
    Teli, Despoina
    Dalenback, Jan-Olof
    Ekberg, Lars
    Psomas, Theofanis
    Langer, Sarka
    [J]. BUILDING AND ENVIRONMENT, 2023, 240
  • [2] Investigation of Indoor Air Quality in Primary School Classrooms
    Hou, Yuefei
    Liu, Junjie
    Li, Jiayu
    [J]. 9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 830 - 837
  • [3] The Effect of Ventilation Strategies on Indoor Air Quality and Energy Consumptions in Classrooms
    Stabile, Luca
    Massimo, Angelamaria
    Canale, Laura
    Russi, Aldo
    Andrade, Alexandro
    Dell'Isola, Marco
    [J]. BUILDINGS, 2019, 9 (05)
  • [4] Indoor Air Quality in UK School Classrooms Ventilated by Natural Ventilation Windcatchers
    Jones, Benjamin M.
    Kirby, Ray
    [J]. INTERNATIONAL JOURNAL OF VENTILATION, 2012, 10 (04) : 323 - 337
  • [5] Indoor Air Quality Performance of Ventilation Systems in Classrooms
    Moon, Hyeun Jun
    Sohn, Jong-Ryeul
    Hwang, Taeyon
    [J]. JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2016, 15 (02) : 343 - 348
  • [6] Year long monitoring of indoor air quality and ventilation in school classrooms in Victoria, Australia
    Rajagopalan, Priyadarsini
    Andamon, Mary Myla
    Woo, Jin
    [J]. ARCHITECTURAL SCIENCE REVIEW, 2022, 65 (01) : 1 - 13
  • [7] Ventilation strategies to improve indoor air quality
    Luo, Q
    Tang, G
    Huang, W
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 3313 - 3317
  • [8] Evaluating the risk of mixtures in the indoor air of primary school classrooms
    Nitika Mishra
    Godwin A. Ayoko
    Tunga Salthammer
    Lidia Morawska
    [J]. Environmental Science and Pollution Research, 2015, 22 : 15080 - 15088
  • [9] Evaluating the risk of mixtures in the indoor air of primary school classrooms
    Mishra, Nitika
    Ayoko, Godwin A.
    Salthammer, Tunga
    Morawska, Lidia
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2015, 22 (19) : 15080 - 15088
  • [10] Ventilation for Energy Efficiency and Improved Indoor Air Quality in University Classrooms
    Kumar, Sangeetha
    Nguyen, Annette
    Gayler, Kate
    Madigan, Grace
    Xing, Rachel
    Novoselac, Atila
    [J]. IAQ 2020: INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES, PT 2, 2022,