Background: The aims of this study were to determine the rate of false-positive diagnosis with EUS-guided fine-needle aspiration and to identify factors contributing to this type of error. Methods: The records of 577 patients undergoing EUS-guided fine-needle aspiration were reviewed and a subset of 188 patients with malignant cytology who underwent surgery was identified. Operative histopathology was compared with EUS-guided fine-needle aspiration cytopathology and false-positive cases were identified. An experienced cytopathologist, who was not involved with the original interpretation of the specimens, reviewed these cases to identify any factor(s) contributing to the errors. Results: Three cases of false-positive diagnosis were identified (1.6%; 95% Cl [0.3%9 4.6%]). By aspiration site, the false-positive rates were as follows: pancreas 2/39 (5.1%),95% Cl [0.6%,17.3%]; lymph nodes 1/136 (0.7%), 95% CI [0.02%, 4.0%]; and other sites 0/13, 95% Cl [0.0%, 24.7%]. In both instances of a false-positive diagnosis for a pancreatic aspiration cytologic specimen, interpretative errors were identified. The false-positive interpretation of cytologic material aspirated from a lymph node occurred in a patient without any evidence for malignancy at surgery. In 111 patients with confirmed esophageal, gastric, or rectal malignancy undergoing EUS-guided fine-needle aspiration of nonperitumoral lymph nodes, there was no false-positive diagnosis, suggesting that specimen contamination by luminal tumor is rare. Conclusion: The overall rate of false-positive diagnosis for EUS-guided fine-needle aspiration is similar to that reported for other modalities. Most false-positive diagnoses are caused by interpretation errors.
引用
收藏
页码:868 / 872
页数:5
相关论文
共 50 条
  • [1] The rate of false-positive results with EUS-guided fine needle aspiration (FNA)
    Schwartz, DA
    Unni, K
    Levy, MJ
    Clain, JE
    Parker, MK
    Wiersema, MJ
    GASTROINTESTINAL ENDOSCOPY, 2002, 55 (05) : AB237 - AB237
  • [2] EUS-guided fine-needle aspiration in the mediastinum
    Barawi, M
    Gress, M
    GASTROINTESTINAL ENDOSCOPY, 2000, 52 (06) : S12 - S17
  • [3] Effectiveness of EUS-Guided Fine-Needle Biopsy versus EUS-Guided Fine-Needle Aspiration: A Retrospective Analysis
    Kuraoka, Naosuke
    Hashimoto, Satoru
    Matsui, Shigeru
    Terai, Shuji
    DIAGNOSTICS, 2021, 11 (06)
  • [4] Assessment of complications of EUS-guided fine-needle aspiration
    O'Toole, D
    Palazzo, L
    Arotçarena, R
    Dancour, A
    Aubert, A
    Hammel, P
    Amaris, J
    Ruszniewski, P
    GASTROINTESTINAL ENDOSCOPY, 2001, 53 (04) : 470 - 474
  • [5] Clinical Impact of EUS-Guided Fine-Needle Aspiration
    Chennat, Jennifer
    Waxman, Irving
    NEW CHALLENGES IN GASTROINTESTINAL ENDOSCOPY, 2008, : 517 - 525
  • [6] Maximizing the yield of EUS-guided fine-needle aspiration
    Chang, KJ
    GASTROINTESTINAL ENDOSCOPY, 2002, 56 (04) : S28 - S34
  • [7] Diagnostic value of SpyGlass for pancreatic cystic lesions: comparison of EUS-guided fine-needle aspiration and EUS-guided fine-needle aspiration combined with SpyGlass
    Du, Chen
    Chai, Ningli
    Linghu, Enqiang
    Li, Huikai
    Feng, Xiuxue
    Wang, Xiangdong
    Tang, Ping
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2022, 36 (02): : 904 - 910
  • [8] Diagnostic value of SpyGlass for pancreatic cystic lesions: comparison of EUS-guided fine-needle aspiration and EUS-guided fine-needle aspiration combined with SpyGlass
    Chen Du
    Ningli Chai
    Enqiang Linghu
    Huikai Li
    Xiuxue Feng
    Xiangdong Wang
    Ping Tang
    Surgical Endoscopy, 2022, 36 : 904 - 910
  • [9] Randomized crossover trial comparing EUS-guided fine-needle aspiration with EUS-guided fine-needle biopsy for gastric subepithelial tumors
    Iwai, Tomohisa
    Kida, Mitsuhiro
    Imaizumi, Hiroshi
    Miyazawa, Shiro
    Okuwaki, Kosuke
    Yamauchi, Hiroshi
    Kaneko, Toru
    Hasegawa, Rikiya
    Miyata, Eiji
    Koizumi, Wasaburo
    DIAGNOSTIC CYTOPATHOLOGY, 2018, 46 (03) : 228 - 233
  • [10] Detection of pancreatic metastases by EUS-guided fine-needle aspiration
    Fritscher-Ravens, A
    Sriram, PVJ
    Krause, C
    Jaeckle, S
    Thonke, F
    Brand, B
    Bohnacker, S
    Soehendra, N
    GASTROINTESTINAL ENDOSCOPY, 2001, 53 (01) : 65 - 70