Reliability of Goniometric Measurements of Flexion in Total Knee Arthroplasty Patients: with Special Reference to the Body Position

被引:15
|
作者
Unver, Bayram [1 ]
Karatosun, Vasfi [2 ]
Bakirhan, Serkan [1 ]
机构
[1] Dokuz Eylul Univ, Sch Physiotherapy, TR-35330 Izmir, Turkey
[2] Dokuz Eylul Univ, Dept Orthopaed & Traumatol, TR-35330 Izmir, Turkey
关键词
Total knee arthroplasty; Goniometry; Reliability; CONTINUOUS PASSIVE MOTION; INTERTESTER RELIABILITY; UNIVERSAL GONIOMETERS; FOLLOW-UP; RANGE; REHABILITATION; VALIDITY; REPLACEMENT; TRIAL; HIP;
D O I
10.1589/jpts.21.257
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
[Purpose] To compare the reliability of goniometric measurements of knee flexion obtained in three different body positions of patients with total knee arthroplasty (TKA). [Subjects] The knees ( 15 1) of 92 TKA patients were the subjects of this study. [Methods] The range of flexion was measured at three instances: preoperatively, postoperative fifth day and at the time of discharge by universal goniometer measurement with the patient positioned in the supine, prone and sitting positions. [Results] There were no significant differences between the range of motion measurements in the three testing positions at the three instances. Also, the results from the three different testing positions were highly correlated (r>0.80). [Conclusion] The results of this study indicate that the position of the patient during the evaluation of range of knee flexion does not affect the results and that the three different body positions can be used interchangeably.
引用
收藏
页码:257 / 262
页数:6
相关论文
共 50 条
  • [1] Influence of hip position on knee flexion angle in patients undergoing total knee arthroplasty
    Matsumoto, T
    Tsumura, N
    Kubo, S
    Shiba, R
    Kurosaka, M
    Yoshiya, S
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (05): : 669 - 673
  • [2] VALIDITY AND RELIABILITY OF GONIOMETRIC MEASUREMENTS AT THE KNEE
    GOGIA, P
    BRAATZ, JH
    ROSE, SJ
    [J]. PHYSICAL THERAPY, 1985, 65 (05): : 700 - 700
  • [3] RELIABILITY AND VALIDITY OF GONIOMETRIC MEASUREMENTS AT THE KNEE
    GOGIA, PP
    BRAATZ, JH
    ROSE, SJ
    NORTON, BJ
    [J]. PHYSICAL THERAPY, 1987, 67 (02): : 192 - 195
  • [4] Increased flexion position of the femoral component reduces the flexion gap in total knee arthroplasty
    Georg Matziolis
    Robert Hube
    Carsten Perka
    Doerte Matziolis
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 1092 - 1096
  • [5] Increased flexion position of the femoral component reduces the flexion gap in total knee arthroplasty
    Matziolis, Georg
    Hube, Robert
    Perka, Carsten
    Matziolis, Doerte
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (06) : 1092 - 1096
  • [6] Alignment in knee flexion position during navigation-assisted total knee arthroplasty
    Yang, Jae-Hyuk
    Dahuja, Anshul
    Kim, Jin-Kak
    Yun, Se-Hyeok
    Yoon, Jung-Ro
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (08) : 2422 - 2429
  • [7] Alignment in knee flexion position during navigation-assisted total knee arthroplasty
    Jae-Hyuk Yang
    Anshul Dahuja
    Jin-Kak Kim
    Se-Hyeok Yun
    Jung-Ro Yoon
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 2422 - 2429
  • [8] High flexion total knee arthroplasty
    Anz, Adam W.
    Jinnah, Riyaz
    [J]. CURRENT ORTHOPAEDIC PRACTICE, 2009, 20 (01): : 40 - 46
  • [9] Total knee arthroplasty with limitations of flexion
    Massin, P.
    Lautridou, C.
    Cappelli, M.
    Petit, A.
    Odri, G.
    Ducellier, F.
    Sabatier, C.
    Hulet, C.
    Canciani, J. P.
    Letenneur, J.
    Burdin, P.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2009, 95 (04) : S1 - S6
  • [10] Flexion contracture in total knee arthroplasty
    Bellemans, Johan
    Vandenneucker, Hilde
    Victor, Jan
    Vanlauwe, Johan
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) : 78 - 82