An experimental study of endovascular brachytherapy using liquid 32P filled balloon catheter

被引:0
|
作者
Wang, RS [1 ]
Huo, Y [1 ]
Chen, M [1 ]
Liu, ZP [1 ]
Zhu, GY [1 ]
机构
[1] Beijing Med Univ, Teaching Hosp 1, Beijing 100034, Peoples R China
关键词
brachytherapy; restenosis; interventional therapy;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To observe the effect of endovascular brachytherapy on the prevention of restenosis after interveneional therapy and to investigate its possible mechanisms. Methods In the balloon-injuried rabbit model, pathological sections of iliac arteries were observed and the changes of vascular histomorphology were estimated by computer analysis of photomicrograms. Using immunohistochemical techniques, proliferating cell nuclear antigen (PCNA) was quantified to assess the proliferation of vascular smooth muscle cells. Results After rabbit iliac arteries were injured by balloon overstretch angioplasty, neointima were shown to be less proliferative in the irradiated group than in the control group, from PCNA scores. The formation of neointima was suppressed with the external elastic laminar area increasing and without the luminal area decreasing in the irradiation group. Conclusion Endovascular brachytherapy using a liquid P-32 filled balloon catheter system could prevent restenosis possibly by inhibiting the formation of neointima and improving positive vascular remodeling.
引用
收藏
页码:225 / 227
页数:3
相关论文
共 50 条
  • [1] An experimental study of endovascular brachytherapy using liquid 32P filled balloon catheter
    王日胜
    霍勇
    陈明
    刘兆平
    朱国英
    中华医学杂志(英文版), 2000, (03) : 33 - 35
  • [2] Experimental dosimetry of a 32P catheter-based endovascular brachytherapy source
    Piermattei, A
    Fidanzio, A
    Perrone, F
    Azario, L
    Grimaldi, L
    Viola, P
    Capote, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (15): : 2283 - 2296
  • [3] 32P endovascular brachytherapy source experimental dosimetry
    Fidanzio, A
    Perrone, F
    Azario, L
    Grimaldi, L
    Capote, R
    Piermattei, A
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S87 - S87
  • [4] Dosimetry of beta nuclide filled balloon catheter in endovascular brachytherapy
    Chen, YM
    Geng, JH
    Tian, JH
    Yin, DY
    Chen, SZ
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2004, 14 (03) : 337 - 339
  • [5] Infusional brachytherapy with colloidal 32P: Clinical and experimental studies
    Nguyen, H
    Lemort, MP
    Andry, G
    Roelandts, M
    Hubloux, G
    Van Houtte, P
    RADIOLOGY, 1998, 209P : 362 - 362
  • [6] Relative dosimetry verification of a 32P endovascular brachytherapy source with radiographic film
    Torres, J
    Gonzalez, A
    Buades, MJ
    Martinez, JA
    Castro, I
    Sema, A
    Campos, PA
    Tobarra, B
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S84 - S84
  • [7] EXPERIMENTAL STUDY OF APOPTOSIS OF SMCs INVITRO BY (32)~P WITH BALLOON CATHETER
    毛家亮
    徐迎佳
    黄定九
    袁济民
    胡建达
    Medical Bulletin of Shanghai Jiaotong University, 1998, (Z1) : 52 - 55
  • [8] Thermoluminescence dosimetry in evaluation of liquid 32P sources for intravascular brachytherapy
    Bilski, P
    Ochab, E
    Petelenz, B
    Walichiewicz, P
    Wodniecki, J
    RADIATION MEASUREMENTS, 2000, 32 (03) : 205 - 210
  • [9] Recurrent renal arterial stenosis - Endovascular brachytherapy with rhenium-188-filled balloon catheter
    Kotzerke, J
    Gabelmann, A
    Hanke, H
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (09): : 1176 - 1178
  • [10] Dosimetry characterization of 32P catheter-based vascular brachytherapy source wire
    Mourtada, FA
    Soares, CG
    Seltzer, SM
    Lott, SH
    MEDICAL PHYSICS, 2000, 27 (08) : 1770 - 1776