The need for flexible biosensors has increased because of their potential applications for point-of-care diagnosis and wearable biosensors. However, flexible biosensors have low sensitivity due to the flexibility of the electrode, and their fabrication involves complex processes. To overcome these limitations, a flexible electrochemical enzyme biosensor was developed in this study by immobilizing an enzyme on the flexible polymer electrode modified with a gold/MoS2/gold nanofilm. The fabrication process involved sputter deposition of gold, spin coating of MoS2, and sputter deposition of gold on the flexible polymer electrode (commercially available Kapton polyimide film). The flexible glucose biosensor was made by immobilization of glucose oxidase on a flexible electrode by using a chemical linker. The detection limit for glucose was estimated to be 10 nM, which indicates more sensitivity as compared with a previously reported flexible glucose sensor. This sensitivity is due to the facilitation of electron transfer by MoS2. The flexure extension of this biosensor was estimated at 3.48 mm, which is much higher than that of the rigid sensor using a gold-coated silicon electrode (0.09 mm), according to measurements with a micro-fatigue tester. The proposed flexible biosensor composed of the enzyme/gold/MoS2/gold nanofilm on the polymer electrode can be used as a flexible sensing platform for developing wearable biosensing systems because of its high sensitivity, high flexibility, and simple fabrication process.
引用
收藏
页码:83 / 89
页数:7
相关论文
共 50 条
  • [1] In situ synthesis of MoS2 on a polymer based gold electrode platform and its application in electrochemical biosensing
    Kim, Hyeong-U
    Kim, Hyeyoun
    Ahn, Chisung
    Kulkarni, Atul
    Jeon, Minhwan
    Yeom, Geun Young
    Lee, Min-Ho
    Kim, Taesung
    [J]. RSC ADVANCES, 2015, 5 (14): : 10134 - 10138
  • [2] Direct electrochemistry of glucose oxidase and a biosensor for glucose based on a glass carbon electrode modified with MoS2 nanosheets decorated with gold nanoparticles
    Su, Shao
    Sun, Haofan
    Xu, Fei
    Yuwen, Lihui
    Fan, Chunhai
    Wang, Lianhui
    [J]. MICROCHIMICA ACTA, 2014, 181 (13-14) : 1497 - 1503
  • [3] Direct electrochemistry of glucose oxidase and a biosensor for glucose based on a glass carbon electrode modified with MoS2 nanosheets decorated with gold nanoparticles
    Shao Su
    Haofan Sun
    Fei Xu
    Lihui Yuwen
    Chunhai Fan
    Lianhui Wang
    [J]. Microchimica Acta, 2014, 181 : 1497 - 1503
  • [4] Electrochemical determination of hydrazine by using MoS2 nanostructure modified gold electrode
    Rana, Dharmender Singh
    Thakur, Nagesh
    Thakur, Sourbh
    Singh, Dilbag
    [J]. NANOFABRICATION, 2022, 7
  • [5] A Simple α-Ketoglutarate Electrochemical Biosensor Based on Reduced MoS2 Nanoparticle-Gold Nanoparticle Nanocomposite
    Yu, Yadong
    Wu, Na
    Peng, Gang
    Li, Tao
    Jiang, Ling
    Huang, He
    [J]. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2018, 18 (01) : 576 - 582
  • [6] An Amperometric Biosensor for Glucose Based on Electrodeposited Redox Polymer/Glucose Oxidase Film on a Gold Electrode
    Junjie Fei
    Yunhua Wu
    Xiaobo Ji
    Jing Wang
    Shengshui Hu
    Zhiqiang Gao
    [J]. Analytical Sciences, 2003, 19 : 1259 - 1263
  • [7] An amperometric biosensor for glucose based on electrodeposited redox polymer/glucose oxidase film on a gold electrode
    Fei, JJ
    Wu, YH
    Ji, XB
    Wang, J
    Hu, SS
    Gao, ZQ
    [J]. ANALYTICAL SCIENCES, 2003, 19 (09) : 1259 - 1263
  • [8] An Electrochemical DNA Biosensor Based on Gold Nanofilm and Stable Y Junction Structure
    Dong, Xiaoya
    Zhao, Weiwei
    Sun, Guobao
    Xu, Jingjuan
    Chen, Hongyuan
    [J]. ACTA CHIMICA SINICA, 2012, 70 (13) : 1457 - 1463
  • [9] An electrochemical NADH biosensor based on a nanoporous gold electrode modified with diaphorase and an osmium polymer
    Otero, Fernando
    Mandal, Tanushree
    Leech, Donal
    Magner, Edmond
    [J]. SENSORS AND ACTUATORS REPORTS, 2022, 4
  • [10] An electrochemical sulfite biosensor based on gold coated magnetic nanoparticles modified gold electrode
    Rawal, Rachna
    Chawla, Sheetal
    Pundir, Chandra Shekhar
    [J]. BIOSENSORS & BIOELECTRONICS, 2012, 31 (01): : 144 - 150