Exergy Analysis of Fluidized Desiccant Cooling System

被引:4
|
作者
Rogala, Zbigniew [1 ]
Kolasinski, Piotr [1 ]
机构
[1] Wroclaw Univ Sci & Technol, Dept Thermodynam Theory Machines & Thermal Syst, Wybrzeze Wyspianskiego 27, PL-50370 Wroclaw, Poland
关键词
fluidized bed; desiccant cooling; adsorption; exergy destruction; exergy efficiency; MASS-TRANSFER; HEAT-EXCHANGER; ADSORPTION; DEHUMIDIFICATION; DESORPTION; MODEL; BEDS;
D O I
10.3390/e21080757
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
One of the main challenges in the design and implementation of fluidized desiccant cooling (FDC) systems is increasing their low COP (coefficient of performance). Exergy analysis is one of the tools especially suitable for improvement and optimization of FDC systems. The improvement of performance is impossible as long as the main sources of exergy destruction are not identified and evaluated. In this paper, the exergy analysis was applied in order to identify these components and processes of the FDC system that are mainly responsible for exergy destruction. Moreover, the exergy efficiency of a simple fluidized desiccant cooler was determined. The results showed that fluidized beds and regenerative heat exchanger were the main exergy destruction sources with a 32% and 18% share of total exergy destruction, respectively. On the other hand, the direct evaporative cooler and air cooler placed after the desorbing fluidized bed were characterized by the lowest exergy efficiencies. This work contributes to better understanding of FDC operation principles and improvement of the performance of FDC technology.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Exergy analysis of a liquid desiccant evaporative cooling system
    Peng, Donggen
    Zhou, Junming
    Luo, Danting
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 82 : 495 - 508
  • [2] Exergy Analysis of Liquid Desiccant Dehumidification System
    Xiong, Z. Q.
    Dai, Y. J.
    Wang, R. Z.
    [J]. INTERNATIONAL JOURNAL OF GREEN ENERGY, 2010, 7 (03) : 241 - 262
  • [3] A Study on Cooling Performance and Exergy Analysis of Desiccant Cooling System in Various Regeneration Temperature and Outdoor Air Conditions
    Lee, Jang Il
    Hong, Seok Min
    Byun, Jae Ki
    Cho, Young Don
    Lee, Dae Young
    [J]. TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2014, 38 (05) : 413 - 421
  • [4] Exergy Performance Analysis and Optimization of a Desiccant Wheel System
    Mandegari, Mohsen Ali
    Farzad, Somayeh
    Pahlavanzadeh, Hassan
    [J]. JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2015, 7 (03)
  • [5] Absorption chiller waste heat utilization to the desiccant dehumidifier system for enhanced cooling - Energy and exergy analysis
    Hu, Tianxiang
    Shen, Yongting
    Kwan, Trevor Hocksun
    Pei, Gang
    [J]. ENERGY, 2022, 239
  • [6] A comment on the concept of entransy (versus exergy) for the performance assessment of a desiccant cooling system
    Carpinlioglu, Melda Ozdinc
    [J]. ENERGY AND BUILDINGS, 2015, 101 : 163 - 167
  • [7] Energy and exergy analyses of an experimental open-cycle desiccant cooling system
    Kanoglu, M
    Carpinlioglu, MÖ
    Yildirim, M
    [J]. APPLIED THERMAL ENGINEERING, 2004, 24 (5-6) : 919 - 932
  • [8] Performance analysis of ventilation systems with desiccant wheel cooling based on exergy destruction
    Tu, Rang
    Liu, Xiao-Hua
    Hwang, Yunho
    Ma, Fei
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 123 : 265 - 279
  • [9] A New Approach to Exergy Analyses of a Hybrid Desiccant Cooling System Compares to a Vapor Compression System
    Khosravi, S.
    Yau, Y. H.
    Mahlia, T. M. I.
    Saidi, M. H.
    [J]. MECHANICAL AND AEROSPACE ENGINEERING, PTS 1-7, 2012, 110-116 : 2163 - +
  • [10] Performance Analysis of a Desiccant Rotor for Rotational Period in a Desiccant Cooling System
    Pi, Chang Hun
    Ha Kang, Byung
    Chang, Young Soo
    [J]. TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2012, 36 (05) : 523 - 531