A fault-tolerant strategy of hybrid modular multilevel converter based on level adjusting method

被引:6
|
作者
Liu, Yiqi [1 ]
Jin, Yonglin [1 ]
Chen, Jianlong [1 ]
Liu, Yanchao [1 ]
机构
[1] Northeast Forestry Univ, Coll Mech & Elect Engn, Harbin 150040, Peoples R China
基金
中国国家自然科学基金;
关键词
Modular multilevel converter; Hybrid submodule; Submodule fault-tolerant;
D O I
10.1016/j.egyr.2020.11.236
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the advantage of DC fault ride-through and the reduced cost, a hybrid modular multilevel converter (HMMC) has become a promising topology for HVDC applications. However, the complicated configuration of HMMCs with a large number and different types of submodules (SM) increases the risk of submodule failure. This paper proposes a novel HMMC fault-tolerant strategy by adjusting the inserted SM number residing in the fault phases, analyzes voltage fluctuation of the SM capacitor, and designed an SM capacitor voltage controller in coordination with fault-tolerant strategy. Meanwhile, by utilizing the negative voltage output characteristic of FBSMs, this strategy can significantly improve the SM fault tolerance capability of the HMMC. Moreover, as compared to conventional fault-tolerant strategies, the proposed strategy requires fewer components and can be easily implemented. Finally, the effectiveness of the proposed fault-tolerant methods is demonstrated by MATLAB/Simulink under different fault conditions and MMC systems. (C) 2020 The Author(s). Published by Elsevier Ltd.
引用
收藏
页码:312 / 320
页数:9
相关论文
共 50 条
  • [1] Fault-tolerant strategy for modular multilevel converter with nearest level modulation in HVDC system
    Geng, Zhi
    Han, Minxiao
    Xie, Wenqiang
    Yang, Yong
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 158
  • [2] Submodule Fault-Tolerant Strategy for Modular Multilevel Converter with Scalable Control Structure
    Alharbi, Mohammed
    Isik, Semih
    Bhattacharya, Subhashish
    SUSTAINABILITY, 2022, 14 (24)
  • [3] A Fault-Tolerant Method Based on a Modified Selective Harmonic Mitigation Technique for Modular Multilevel Converter
    Aslanian, Mahdi
    Neyshabouri, Yousef
    Raki, Ashkan
    Iman-Eini, Hossein
    Liserre, Marco
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (10) : 12890 - 12899
  • [4] Shared Redundancy Strategy to Improve the Reliability and Fault-Tolerant Capability of Modular Multilevel Converter
    Farzamkia, Saleh
    Rizi, Houshang Salimian
    Huang, Alex Q.
    Iman-Eini, Hossein
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (04) : 3326 - 3336
  • [5] Fault-tolerant Operation Strategy of Modular Multilevel Converter With Multiple Faulty Switches Based on a Simplified SVM
    Bai Z.
    Li Y.
    Ma H.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (20): : 7104 - 7116
  • [6] A Fault-Tolerant Control Strategy for Cascaded Multilevel Converter
    Zhang, Tongshuo
    Liu, Xuebo
    Wei, Tongzhen
    Han, Libo
    CURRENT DEVELOPMENT OF MECHANICAL ENGINEERING AND ENERGY, PTS 1 AND 2, 2014, 494-495 : 1542 - 1547
  • [7] A Fault-Tolerant Approach for Hybrid Modular Multilevel Converter Using Negative Voltage Levels
    Farzamkia, Saleh
    Khoshkbar-Sadigh, Arash
    Dargahi, Vahid
    2021 THIRTY-SIXTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2021), 2021, : 907 - 912
  • [8] Modular Multilevel Converter Modulation Technique with Fault-tolerant Capability
    Hashfi, Tuanku Badzlin
    Mekhilef, Saad
    Ogura, Koki
    Mubin, Marizan
    2019 IEEE 13TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS (PEDS), 2019,
  • [9] Control strategy for fault-tolerant cascaded multilevel converter based STATCOM
    Song, Wenchao
    Huang, Alex Q.
    APEC 2007: TWENTY-SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1 AND 2, 2007, : 1073 - +
  • [10] Fault-tolerant design and control of modular multilevel converter-based STATCOM
    College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
    Dianli Xitong Baohu yu Kongzhi, 2012, 16 (83-89):