A high frequency amplitude-steered array for real-time volumetric imaging

被引:1
|
作者
Frazier, CH
Hughes, WJ
O'Brien, WD
机构
[1] Univ Illinois, Dept Elect & Comp Engn, Bioacoust Res Lab, Urbana, IL 61801 USA
[2] Penn State Univ, Appl Res Lab, State Coll, PA 16801 USA
来源
关键词
D O I
10.1121/1.1518699
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Real-time three-dimensional acoustic imaging is difficult in water or tissue because of the slow speed of sound in these media. Conventional pulse-echo data collection, which uses at least one transmit pulse per line in the image, does not allow for the real-time update of a volume of data at practical ranges. Recently, a linear amplitude-steered array was presented that allows the collection of a plane of data with a single transmit pulse by spatially separating frequencies in the lateral direction. Later, by using a linear array with frequency separation in the vertical direction and rotating the array in the horizontal direction, volumetric data were collected with a small number of transmit pulses. By expanding the linear array to a two-dimensional array, data can now be collected for volumetric imaging in real time. In this study, the amplitude-steered array at the heart of a real-time volumetric sonar imaging system is described, giving the design of the array and describing how data are collected and processed to form images. An analysis of lateral resolution in the vertical and, horizontal directions shows that resolution is improved in the direction of frequency separation over systems that use a broad transmit beam. Images from simulated data are presented. (C) 2002 Acoustical Society of America.
引用
下载
收藏
页码:2742 / 2752
页数:11
相关论文
共 50 条
  • [1] Volumetric imaging with an amplitude-steered array
    Frazier, CH
    Hughes, WJ
    O'Brien, WD
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2002, 112 (06): : 2753 - 2762
  • [2] Image formation with the amplitude-steered array using time-frequency distributions
    Frazier, CH
    O'Brien, WD
    ACOUSTICAL IMAGING, VOL 25, 2000, 25 : 535 - 542
  • [3] Analysis of resolution for an amplitude-steered array
    Frazier, CH
    Hughes, WJ
    O'Brien, WD
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2000, 107 (05): : 2430 - 2436
  • [4] Analysis of resolution for an amplitude-steered array
    2000, American Institute of Physics Inc. (107):
  • [5] Volumetric Real-Time Imaging Using a CMUT Ring Array
    Choe, Jung Woo
    Oralkan, Oemer
    Nikoozadeh, Amin
    Gencel, Mustafa
    Stephens, Douglas N.
    O'Donnell, Matthew
    Sahn, David J.
    Khuri-Yakub, Butrus T.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (06) : 1201 - 1211
  • [6] Real-time rectilinear volumetric imaging using a periodic array
    Yen, JT
    Smith, SW
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (07): : 923 - 931
  • [7] Rapidly-steered single-element ultrasound for real-time volumetric imaging and guidance
    Stauber, Mark
    Western, Craig
    Solek, Roman
    Salisbury, Ken
    Hristov, Dimitre
    Schlosser, Jeffrey
    MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2016, 9786
  • [8] Real-time rectilinear volumetric imaging
    Yen, JT
    Smith, SW
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (01) : 114 - 124
  • [9] A synthetic-focusing strategy for real-time high-frequency annular-array imaging
    Filoux, Erwan
    Ketterling, Jeffrey A.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 1135 - 1138
  • [10] Real-Time Volumetric Thermoacoustic Imaging and Thermometry Using a 1.5-D Ultrasound Array
    Karunakaran, Chandra
    Zhao, Hongbo
    Xin, Hao
    Witte, Russell S.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (04) : 1234 - 1244