Fourteen consecutive elbows have been treated for rheumatoid arthritis (9 elbows) and for post-traumatic osteoarthrosis (5 elbows) by total elbow replacement with the GSB III implant The elbows were reviewed retrospectively after a mean follow-up of 6 years (2 to 9 years). Ten of 14 elbows had a functioning GSB III implant at follow-up; 7 of them were rated satisfactory and 3 unsatisfactory with the Mayo elbow performance score. In 5 of these 10 cases, the patients had significant pain relief with no or only mild pain at follow-up, whereas 5 had moderate to severe pain. With a functioning implant the range of motion averaged 140 degrees of flexion, 19 degrees of lack of extension, 65 degrees of pronation, and 84 degrees of supination. Six (43%) elbows had major complications requiring 1 to 8 additional operations. Aseptic loosening requiring revision occurred in 4 (29%) elbows. Two of them were treated by a resection arthroplasty, and 2 were revised with another hinged semiconstrained device. Three Further elbows had radiolucent lines involving more than 50% of the cement-bone interface of either the humeral or the ulnar component. However, in 8 elbows the cementing technique was considered marginal or inadequate. Poor cementing (marginal or inadequate) was associated with loosening (P =.008). The GSB III total elbow prosthesis can restore function and reduce pain. The rate of aseptic loosening in this series was higher than previously reported. Based on this observation, we conclude that the GSB III implant seems to be sensitive to the insertion technique and does not tolerate suboptimal cementing.
引用
收藏
页码:135 / 139
页数:5
相关论文
共 50 条
  • [1] GSB III total elbow replacement in rheumatoid arthritis
    Cesar, M.
    Roussanne, Y.
    Bonnel, F.
    Canovas, F.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (03): : 330 - 334
  • [2] RESULTS OF TOTAL ELBOW REPLACEMENT - 13 CASES USING GSB HINGE PROSTHESIS
    GARRETT, JC
    EWALD, FC
    THOMAS, WH
    SLEDGE, CB
    [J]. ARTHRITIS AND RHEUMATISM, 1975, 18 (04): : 399 - 400
  • [3] ARTHROPLASTY OF THE ELBOW - EXPERIENCE WITH THE MARK III GSB PROSTHESIS
    BELL, S
    GSCHWEND, N
    STEIGER, U
    [J]. AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1986, 56 (11): : 823 - 827
  • [4] ARTHROPLASTY OF THE ELBOW - EXPERIENCE WITH THE MARK-III GSB PROSTHESIS
    BELL, S
    GSCHWEND, N
    STEIGER, U
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (01): : 159 - 159
  • [5] ELBOW ARTHROPLASTY WITH GSB PROSTHESIS
    GSCHWEND, N
    SCHEIER, HJG
    BAHLER, A
    [J]. LANGENBECKS ARCHIV FUR CHIRURGIE, 1973, 334 : 978 - 978
  • [6] ARTHROPLASTIC OF THE ELBOW WITH THE GSB-ELBOW PROSTHESIS
    SCHERER, M
    MUNZINGER, U
    SCHEIER, H
    GSCHWEND, N
    [J]. ORTHOPADE, 1981, 10 (04): : 340 - 343
  • [7] Experiences with the GSB-elbow prosthesis
    Machner, A
    Pap, G
    Schenk, K
    Merk, H
    Neumann, HW
    [J]. ZENTRALBLATT FUR CHIRURGIE, 1999, 124 (11): : 993 - 998
  • [8] SEMICONSTRAINED ELBOW PROSTHESES WITH SPECIAL REFERENCE TO THE GSB-III PROSTHESIS
    GSCHWEND, N
    LOEHR, J
    IVOSEVICRADOVANOVIC, D
    SCHEIER, H
    MUNZINGER, U
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (232) : 104 - 111
  • [9] Role of collateral ligaments in the GSB-linked total elbow prosthesis
    Herren, DB
    O'Driscoll, SW
    An, KN
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2001, 10 (03) : 260 - 264
  • [10] TOTAL REPLACEMENT OF THE RHEUMATOID ELBOW WITH A HINGELESS PROSTHESIS
    KUDO, H
    IWANO, K
    WATANABE, S
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (02): : 277 - 285