Non-invasive Fetal Electrocardiography for Intrapartum Cardiotocography

被引:13
|
作者
Vullings, Rik [1 ,2 ]
van Laar, Judith O. E. H. [3 ]
机构
[1] Eindhoven Univ Technol, Dept Elect Engn, Biomed Diagnost Lab Eindhoven, Eindhoven, Netherlands
[2] Nemo Healthcare, Veldhoven, Netherlands
[3] Maxima Med Ctr, Veldhoven, Netherlands
来源
FRONTIERS IN PEDIATRICS | 2020年 / 8卷
基金
欧盟地平线“2020”;
关键词
electrophysiology; cardiotocography; fetal heart rate; fetal electrocardiogram; signal processing; artificial intelligence; R-PEAK DETECTION; FREQUENCY-ANALYSIS; ECG EXTRACTION; ELECTROHYSTEROGRAPHY; RELIABILITY; ULTRASOUND; ACCURACY; PRESSURE;
D O I
10.3389/fped.2020.599049
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Fetal monitoring is important to diagnose complications that can occur during pregnancy. If detected timely, these complications might be resolved before they lead to irreversible damage. Current fetal monitoring mainly relies on cardiotocography, the simultaneous registration of fetal heart rate and uterine activity. Unfortunately, the technology to obtain the cardiotocogram has limitations. In current clinical practice the fetal heart rate is obtained via either an invasive scalp electrode, that poses risks and can only be applied during labor and after rupture of the fetal membranes, or via non-invasive Doppler ultrasound technology that is inaccurate and suffers from loss of signal, in particular in women with high body mass, during motion, or in preterm pregnancies. In this study, transabdominal electrophysiological measurements are exploited to provide fetal heart rate non-invasively and in a more reliable manner than Doppler ultrasound. The performance of the fetal heart rate detection is determined by comparing the fetal heart rate to that obtained with an invasive scalp electrode during intrapartum monitoring. The performance is gauged by comparing it to performances mentioned in literature on Doppler ultrasound and on two commercially-available devices that are also based on transabdominal fetal electrocardiography.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Ventricular bigeminy misdiagnosed as fetal bradycardia by cardiotocography - the value of non-invasive fetal electrocardiography
    Chia, EL
    Ho, TF
    Wong, YC
    Yip, WCL
    [J]. JOURNAL OF PERINATAL MEDICINE, 2004, 32 (06) : 532 - 534
  • [2] A comparison of intrapartum automated fetal electrocardiography and conventional cardiotocography -: assessment of outcome
    Amer-Wahlin, I.
    Rosen, K. G.
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2006, 113 (11)
  • [3] Comparison of short-term variation derived from ambulatory non-invasive fetal electrocardiography with computerised cardiotocography
    Liu, Becky
    Thilaganathan, Basky
    Bhide, Amar
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2023, 130 : 20 - 21
  • [4] Intrapartum ST Segment Analyses (STAN) Using Simultaneous Invasive and Non-Invasive Fetal Electrocardiography: A Report of 6 Cases
    Reinhard, J.
    Hayes-Gill, B.
    Yuan, J.
    Schiermeier, S.
    Louwen, F.
    [J]. ZEITSCHRIFT FUR GEBURTSHILFE UND NEONATOLOGIE, 2014, 218 (03): : 122 - +
  • [5] Non-invasive intrapartum fetal ECG: preliminary report
    Taylor, MJO
    Thomas, MJ
    Smith, MJ
    Oseku-Afful, S
    Fisk, NM
    Green, AR
    Paterson-Brown, S
    Gardiner, HM
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2005, 112 (08) : 1016 - 1021
  • [6] Non-invasive fetal electrocardiography in singleton and multiple pregnancies
    Taylor, MJO
    Smith, MJ
    Thomas, M
    Green, AR
    Cheng, F
    Oseku-Afful, S
    Wee, LY
    Fisk, NM
    Gardiner, HM
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2003, 110 (07) : 668 - 678
  • [7] A comparison of intrapartum automated fetal electrocardiography and conventional cardiotocography -: a randomised controlled study
    Ojala, K
    Vääräsmäki, M
    Mäkikallio, K
    Valkama, M
    Tekay, A
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2006, 113 (04) : 419 - 423
  • [8] A comparison of intrapartum automated fetal electrocardiography and conventional cardiotocography - a randomised controlled study
    Westerhuis, M.
    Porath, M.
    Mol, B. W.
    Kwee, A.
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2006, 113 (09) : 1103 - 1103
  • [9] A comparison of intrapartum automated fetal electrocardiography and conventional cardiotocography - a randomised controlled study
    Campbell, L.
    Parisaei, M.
    Erskinea, K. J.
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2006, 113 (08) : 980 - 980
  • [10] A comparison of intrapartum automated fetal electrocardiography and conventional cardiotocography - a randomised controlled study
    Majeed, R.
    Fahy, U.
    Burke, G.
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2006, 113 (11)