Depth of insertion of the ProSeal™ laryngeal mask airway

被引:18
|
作者
Stix, MS [1 ]
O'Connor, CJ [1 ]
机构
[1] Lahey Clin Fdn, Dept Anesthesiol, Burlington, MA 01805 USA
关键词
equipment; masks anaesthesia;
D O I
10.1093/bja/aeg041
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. The depth of insertion of the ProSeal(TM) laryngeal mask airway (PLMAdagger) is unknown. We measured depth of insertion in satisfactorily positioned PLMAs. Methods. All women received size 4 masks and men size 5 masks. We measured the position of the integral bite block in relation to the upper incisors documented in patients over a 6-month period. Depth of insertion was scored by dividing the integral bite block into quarters. Satisfactory positioning of the ProSeal(TM) itself was determined by (i) positive 'suprasternal notch test', (ii) no venting via the drain tube during maximal lung inflation, and (iii) an unobstructed airway. Results. We studied 274 patients (147 women and 127 men). The midway point of the bite block was proximal to the incisors (e.g. within the oropharynx) in 78% of women (95% Cl 71-85%) and 92% of men (95% Cl 87-97). The standard deviation for the depth distribution in women was 0.8 cm and for men was 1.0 cm. Conclusions. Usually most of the integral bite block lies within the oropharynx. It was never normal for the entire bite block to stick out of the mouth (4 SD from the mean for both men and women). The position of the integral bite block relative to the upper incisors gives valuable information during assessment of PLMA position.
引用
收藏
页码:235 / 237
页数:3
相关论文
共 50 条
  • [1] Optimizing insertion of the ProSeal laryngeal mask airway
    Tim Cook
    Cornelius J. O’Connor
    Michael S. Stix
    Dennis R. Valade
    [J]. Canadian Journal of Anesthesia, 2005, 52 : 885 - 886
  • [2] Optimizing insertion of the ProSeal laryngeal mask airway
    Cook, T
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2005, 52 (08): : 885 - 886
  • [3] Transilluminated ProSeal™ laryngeal mask airway insertion
    Chen, J.
    Lu, K. -Z.
    [J]. ANAESTHESIA AND INTENSIVE CARE, 2012, 40 (02) : 364 - 365
  • [4] Trachlight assisted proseal laryngeal mask airway insertion
    Mahajan, Rajesh
    Batra, Yatinder Kumar
    [J]. PEDIATRIC ANESTHESIA, 2009, 19 (04) : 412 - 413
  • [5] Optimizing insertion of the ProSeal laryngeal mask airway - Reply
    O'Connor, CJ
    Stix, MS
    Valade, DR
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2005, 52 (08): : 886 - 886
  • [6] Facilitated insertion of the ProSeal™ laryngeal mask airway using a lightwand
    W. Alan C. Mutch
    [J]. Canadian Journal of Anesthesia, 2006, 53 : 635 - 636
  • [7] Insertion of the ProSeal™ laryngeal mask airway with the 90° rotation technique
    Fu S. Xue
    Qiang Wang
    Yu Jing Yuan
    Jun Xiong
    [J]. Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2010, 57 : 622 - 623
  • [8] Another technique to facilitate insertion of the ProSeal™ laryngeal mask airway
    Michael Beriault
    [J]. Canadian Journal of Anesthesia, 2007, 54
  • [9] Insertion of the ProSeal™ laryngeal mask airway with the 90° rotation technique
    Jeon, Young-Tae
    Na, Hyo Seok
    Park, Sang-Hyun
    Oh, Ah-Young
    Yun, Mi-Ja
    Kim, Jin Hee
    Hwang, Jung-Won
    Park, Hee-Pyoung
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2010, 57 (06): : 623 - 623
  • [10] Another technique to facilitate insertion of the ProSeal™ laryngeal mask airway
    Beriault, Michael
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (05): : 399 - 399