Pilot study of a noninvasive real-time optical backscatter probe in liver transplantation

被引:1
|
作者
Richards, James A. [1 ,2 ,3 ]
Randle, Lucy V. [1 ,2 ,3 ]
Butler, Andrew J. [1 ,2 ,3 ]
Martin, Jack L. [1 ,2 ,3 ]
Fedotovs, Arturs [1 ,2 ,3 ]
Davies, Susan E. [4 ]
Watson, Christopher J. E. [1 ,2 ,4 ]
Robertson, Paul A. [5 ]
机构
[1] Univ Cambridge, Addenbrookes Hosp, Dept Surg, Cambridge, England
[2] Univ Cambridge Collaborat Newcastle Univ & Partne, NIHR Blood & Transplant Res Unit BTRU, Cambridge, England
[3] Natl Inst Hlth Res NIHR Cambridge Biomed Res Ctr, Cambridge, England
[4] Addenbrookes Hosp, Cambridge Univ Hosp, Dept Pathol, Cambridge, England
[5] Univ Cambridge, Elect Engn Div, Dept Engn, Cambridge, England
关键词
deceased donation; fatty liver disease; hepatic steatosis; liver transplantation outcomes; medical device; EARLY ALLOGRAFT DYSFUNCTION; HEPATIC STEATOSIS; NORMOTHERMIC PERFUSION; FATTY LIVERS; SPECTROSCOPY; SURVIVAL; DISEASE; END;
D O I
10.1111/tri.13823
中图分类号
R61 [外科手术学];
学科分类号
摘要
Transplantation of severely steatotic donor livers is associated with early allograft dysfunction and poorer graft survival. Histology remains the gold standard diagnostic of donor steatosis despite the lack of consensus definition and its subjective nature. In this prospective observational study of liver transplant patients, we demonstrate the feasibility of using a handheld optical backscatter probe to assess the degree of hepatic steatosis and correlate the backscatter readings with clinical outcomes. The probe is placed on the surface of the liver and emits red and near infrared light from the tip of the device and measures the amount of backscatter of light from liver tissue via two photodiodes. Measurement of optical backscatter (Mantel-Cox P < 0.0001) and histopathological scoring of macrovesicular steatosis (Mantel-Cox P = 0.046) were predictive of 5-year graft survival. Recipients with early allograft dysfunction defined according to both Olthoff (P = 0.0067) and MEAF score (P = 0.0097) had significantly higher backscatter levels from the donor organ. Backscatter was predictive of graft loss (AUC 0.75, P = 0.0045). This study demonstrates the feasibility of real-time measurement of optical backscatter in donor livers. Early results indicate readings correlate with steatosis and may give insight to graft outcomes such as early allograft dysfunction and graft loss.
引用
收藏
页码:709 / 720
页数:12
相关论文
共 50 条
  • [1] A PILOT STUDY OF A NON-INVASIVE REAL-TIME OPTICAL BACKSCATTER PROBE IN LIVER TRANSPLANTATION
    Richards, James
    Fedotovs, Arturs
    Butler, Andrew
    Watson, Christopher
    Robertson, Paul
    TRANSPLANT INTERNATIONAL, 2021, 34 : 328 - 328
  • [2] Real-time elastography for noninvasive diagnosis of liver fibrosis
    Kanamoto, Mami
    Shimada, Mitsuo
    Ikegami, Toru
    Imura, Satoru
    Morine, Yuji
    Ikemoto, Tetsuya
    Mori, Hiroki
    Hanaoka, Jun
    Sugimoto, Koji
    Tokunaga, Takuya
    GASTROENTEROLOGY, 2008, 134 (04) : A828 - A828
  • [3] Real-Time Optical Fiber Dosimeter Probe
    Croteau, Andre
    Caron, Serge
    Rink, Alexandra
    Jaffray, David
    Mermut, Ozzy
    OPTICAL FIBERS, SENSORS, AND DEVICES FOR BIOMEDICAL DIAGNOSTICS AND TREATMENT XI, 2011, 7894
  • [4] Fiber-optic probe for noninvasive real-time determination of tissue optical properties at multiple wavelengths
    Dam, JS
    Pedersen, CB
    Dalgaard, T
    Fabricius, PE
    Aruna, P
    Andersson-Engels, S
    APPLIED OPTICS, 2001, 40 (07) : 1155 - 1164
  • [5] MEASUREMENT OF REAL-TIME DIGITAL SIGNALS IN A SILICON BIPOLAR JUNCTION TRANSISTOR USING A NONINVASIVE OPTICAL PROBE
    HEINRICH, HK
    HEMENWAY, BR
    MCGRODDY, KA
    BLOOM, DM
    ELECTRONICS LETTERS, 1986, 22 (12) : 650 - 652
  • [6] Fiber-optic probe for noninvasive real-time determination of tissue optical properties at multiple wavelengths
    Dam, Jan S.
    Pedersen, Carsten B.
    Dalgaard, Torben
    Fabricius, Paul Erik
    Aruna, Prakasa
    Andersson-Engels, Stefan
    Applied Optics, 2001, 40 (07): : 1155 - 1155
  • [7] REAL-TIME COMPUTER-CONTROLLED BACKSCATTER MEASUREMENT OF OPTICAL FIBERS
    EDWARDS, KA
    RIZK, MS
    GRATTAN, KTV
    COMPUTER INTEGRATED MANUFACTURING SYSTEMS, 1994, 7 (04): : 279 - 285
  • [8] Real-time probe
    不详
    MATERIALS PERFORMANCE, 2002, 41 (04) : 12 - 13
  • [9] Fabrication and Characterization of a Real-Time Optical Fiber Dosimeter Probe
    Croteau, Andre
    Caron, Serge
    Rink, Alexandra
    Jaffray, David
    Mermut, Ozzy
    NOVEL BIOPHOTONIC TECHNIQUES AND APPLICATIONS, 2011, 8090
  • [10] REAL-TIME NERVE PROBE
    EDWARDS, A