Evaluation of Titanium Serum Levels in Patients After Spine Instrumentation: Comparison Between Posterolateral and 360° Spinal Fusion Surgery

被引:7
|
作者
Fernandez Bances, Ignacio [1 ]
Paz Aparicio, Jose [2 ]
Alvarez Vega, Marco Antonio [3 ]
机构
[1] Complejo Asistencial Univ Leon, Orthoped Dept, Spine Unit, Leon, Spain
[2] Univ Cent Hosp Asturias, Orthoped Surg & Traumatol Dept, Spine Unit, Oviedo, Spain
[3] Univ Cent Hosp Asturias Huca, Neurosurg Dept, Oviedo, Spain
关键词
serum titanium levels; spine fusion; interbody devices; metal ion release; isotope dilution analysis; TOTAL HIP REPLACEMENTS; METAL-ION RELEASE; ALUMINUM LEVELS; WEAR; CYTOTOXICITY; PARTICLES; NIOBIUM; TISSUES; DEBRIS; BLOOD;
D O I
10.7759/cureus.5451
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction The use of orthopedic implants is a cause for concern for the release of its integrating metals and the systemic complications that may occur. Instrumented spine arthrodesis is the recommended treatment for many spine diseases. Different segmental fixation devices, commonly made of titanium and its alloys, are used in these surgeries. The use of this metal for spinal fusion has introduced the possibility of generating microscopic metal particles that are present in the tissues of the surrounding implants (peri-implant environment). In fact, metal debris has been found in the paraspinal soft tissues of patients with posterior lumbar instrumentation and showed to be particularly high in patients undergoing revision procedures of pseudoarthrosis. In addition, part of the metals might also dissolve (either from the released particles or directly from the implant surface) and circulate in the body fluids, accumulating (eventually) in remote organs. Material and methods A prospective study was designed with patients who were to be operated by the pathology of the lumbar spine to perform a vertebral arthrodesis composed of a titanium alloy (n=32). Two subgroups were differentiated according to the type of surgery performed: a) Posterolateral arthrodesis (N=5); b) Circumferential arthrodesis intervertebral implant of polyester-ether ketone (PEEK) (N=8) or titanium (N=19). The blood sample was taken before surgery and one year later. The samples were analyzed by mass spectrophotometry with a double focus inductive coupling plasma source (DF-ICP-MS). Results Blood titanium levels prior to surgery were similar to those in other publications (0.7449 micrograms per liter(-1) (mu gL(-1)), Standard Deviation (SD)=0.562). The average titanium concentration levels found after surgery was 2.5406 mu gL(-1) (SD=3,69), near 3.5-fold increase. After surgery, there was a significant mean increase in serum titanium levels of 1.7957 mu gL(-1) (SD=3.5765, Range=-0.57 mu gL(-1); 14.60 mu gL(-1)). There is a statistically significant increment (p=0.00049) of the titanium concentration in the serum of the patients after surgery. If we analyze the patients in three groups according to the type of implants used (posterolateral, circumferential with PEEK, and circumferential with titanium), there are no differences between those who did not have an intersomatic device implanted and those in which PEEK implants were implanted, but with those in which it was titanium it was p=0.006 and p=0.018, respectively. Conclusions Patients undergoing vertebral instrumentation experience a significant increase in serum titanium levels compared to before surgery levels. The use of an intersomatic device did not show differences in titanium release with not using it when it was PEEK. There are significant differences between patients without intersomatic implants or those who had a PEEK implant with those in whom it was titanium, with a significant increase in blood titanium levels.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Persistently Raised Serum Titanium Levels After Spinal Instrumentation in Children
    Cundy, Peter J.
    Antoniou, Georgia
    Freeman, Brian J. C.
    Cundy, William J.
    SPINE, 2022, 47 (17) : 1241 - 1247
  • [2] Adjacent segment degeneration after lumbar spinal posterolateral fusion with instrumentation in elderly patients
    Chou, WY
    Hsu, CJ
    Chang, WN
    Wong, CY
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (01) : 39 - 43
  • [3] Adjacent segment degeneration after lumbar spinal posterolateral fusion with instrumentation in elderly patients
    Wen-Ying Chou
    Chien-Jen Hsu
    Wei-Ning Chang
    Chi-Yin Wong
    Archives of Orthopaedic and Trauma Surgery, 2002, 122 : 39 - 43
  • [4] Comparison of Serum CRP and Procalcitonin in Patients after Spine Surgery
    Chung, Yeon Gu
    Won, Yu Sam
    Kwon, Young Joon
    Shin, Hyun Chul
    Choi, Chun Sik
    Yeom, Joon-Sup
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2011, 49 (01) : 43 - 48
  • [5] Circumferential lumbar spinal fusion with Brantigan cage versus posterolateral fusion with titanium Cotrel-Dubousset instrumentation -: A prospective, randomized clinical study of 146 patients
    Christensen, FB
    Hansen, ES
    Eiskjær, SP
    Hoy, K
    Helmig, P
    Neumann, P
    Niedermann, B
    Bünger, CE
    SPINE, 2002, 27 (23) : 2674 - 2683
  • [6] The development of whole blood titanium levels after instrumented spinal fusion - Is there a correlation between the number of fused segments and titanium levels?
    Ipach, Ingmar
    Schaefer, Ralf
    Mittag, Falk
    Leichtle, Carmen
    Wolf, Petra
    Kluba, Torsten
    BMC MUSCULOSKELETAL DISORDERS, 2012, 13
  • [7] The development of whole blood titanium levels after instrumented spinal fusion – Is there a correlation between the number of fused segments and titanium levels?
    Ingmar Ipach
    Ralf Schäfer
    Falk Mittag
    Carmen Leichtle
    Petra Wolf
    Torsten Kluba
    BMC Musculoskeletal Disorders, 13
  • [8] Functional outcome after posterolateral spinal fusion using pedicle screws: Comparison between primary and salvage procedure
    Christensen F.B.
    Thomsen K.
    Eiskjær S.P.
    Gelinick J.
    Bünger C.E.
    European Spine Journal, 1998, 7 (4) : 321 - 327
  • [9] The postsurgical lumbosacral spine - Magnetic resonance imaging evaluation following intervertebral disk surgery, surgical decompression, intervertebral bony fusion, and spinal instrumentation
    Jinkins, JR
    Van Goethem, JWM
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2001, 39 (01) : 1 - +
  • [10] Effects of Lumbar Fusion Instrumentation Removal in Patients Who Experienced Continued Pain After Lumbar Spinal Fusion Surgery for Lumbar Degenerative Disease
    Ucler, Necati
    Cayli, Suleyman Rustu
    TURKISH NEUROSURGERY, 2020, 30 (05) : 763 - 767