The effect of the subacromial balloon spacer on humeral head translation in the treatment of massive, irreparable rotator cuff tears: a biomechanical assessment

被引:23
|
作者
Singh, Supriya [1 ]
Reeves, Jacob [1 ]
Langohr, Daniel G. [1 ]
Johnson, James A. [1 ]
Athwal, George S. [1 ]
机构
[1] St Josephs Hlth Care London, Roth McFarlane Hand & Upper Limb Ctr, 268 Grosvenor St, London, ON N6G 4E7, Canada
关键词
Massive rotator cuff tear; subacromial balloon; irreparable; rotator cuff repair; proximal migration; reverse arthroplasty; cuff tear arthropathy; SUPERIOR CAPSULE RECONSTRUCTION; BIODEGRADABLE SPACER; TREATMENT OPTIONS; STABILITY;
D O I
10.1016/j.jse.2019.03.036
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The current management of massive, irreparable rotator cuff tears is challenging, and no individual surgical technique has demonstrated clinical superiority. This study evaluated the role of a subacromial balloon spacer and its ability to depress the humeral head in the setting of a massive, irreparable rotator cuff tear. Methods: Eight cadaveric shoulders were tested. The specimens were mounted onto a shoulder simulator that applied muscle loading. Five shoulder states were tested: intact; irreparable rotator cuff tear; and inflation of the subacromial balloon spacer with 10, 25, and 40 mL of saline solution on the irreparable rotator cuff tear. Humeral head migration was measured at 0 degrees, 30 degrees, 60 degrees, and 90 degrees of shoulder abduction. Results: After creation of a massive, irreparable rotator cuff tear, in 0' of abduction, the humeral head migrated superiorly by a mean of 3.5 +/- 0.7 mm compared with the intact shoulder state (P = .002). The subacromial balloon spacer inflated to 25 mL translated the humeral head inferiorly relative to the torn state by an average of 3.2 +/- 0.6 mm (P = .001) for all abduction angles. The balloon inflated to 10 mL was ineffective at restoring humeral head position as it was still significantly superior than intact (P = .017). The balloon inflated to 40 mL was successful in depressing the humeral head; however, it overtranslated the humeral head anteroinferiorly, such that it was significantly different from the intact condition (P < .001). Overall, the 25-mL balloon best restored the humeral head position. Conclusion: The results of this study demonstrate that the subacromial balloon spacer is most effective in depressing the humeral head and restoring the glenohumeral joint position when inflated to 25 mL. (C) 2019 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:1841 / 1847
页数:7
相关论文
共 50 条
  • [1] Subacromial Balloon Spacer for Massive Irreparable Rotator Cuff Tears
    Srikumaran, Uma
    Russo, Raffaella
    Familiari, Filippo
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2023, 39 (03): : 576 - 577
  • [2] Subacromial balloon spacer for irreparable rotator cuff tears
    Beard, David
    Chokotho, Linda
    [J]. LANCET, 2022, 399 (10339): : 1920 - 1921
  • [3] The Subacromial Balloon Spacer Versus Superior Capsular Reconstruction in the Treatment of Irreparable Rotator Cuff Tears: A Biomechanical Assessment
    Singh, Supriya
    Reeves, Jacob
    Langohr, G. Daniel G.
    Johnson, James A.
    Athwal, George S.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (02): : 382 - 389
  • [4] Subacromial Spacer for Irreparable Rotator Cuff Tears
    Riff, Andrew J.
    Verma, Nikhil N.
    [J]. OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2018, 26 (01) : 44 - 47
  • [5] Outcomes of Subacromial Balloon Spacer Implantation for Massive and Irreparable Rotator Cuff Tears: A Systematic Review
    Stewart, Russell K.
    Kaplin, Lisa
    Parada, Stephen A.
    Graves, Benjamin R.
    Verma, Nikhil N.
    Waterman, Brian R.
    [J]. ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2019, 7 (10)
  • [6] Subacromial Spacer Implantation for the Treatment of Massive Irreparable Rotator Cuff Tears: A Systematic Review
    Moon, Andrew S.
    Patel, Harshadkumar A.
    Ithurburn, Matthew P.
    Brabston, Eugene W.
    Ponce, Brent A.
    Momaya, Amit M.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (02): : 607 - 614
  • [7] Irreparable Massive Rotator Cuff Tears: Subacromial Balloon Surgical Technique
    Rondon, Alexander J.
    Farronato, Dominic M.
    Pezzulo, Joshua D.
    Abboud, Joseph A.
    [J]. ARTHROSCOPY TECHNIQUES, 2023, 12 (03): : E421 - E432
  • [8] Treatment of massive irreparable rotator cuff tears through biodegradable subacromial InSpace Balloon
    Donato Rosa
    Giovanni Balato
    Giovanni Ciaramella
    Sigismindo Di Donato
    Nicola Auletta
    Claudia Andolfi
    [J]. BMC Surgery, 13 (Suppl 1)
  • [9] Biomechanics of Biodegradable Subacromial Balloon Spacer for Irreparable Superior Rotator Cuff Tears
    Lobao, Mario H.
    Canham, R. Bruce
    Melvani, Roshan T.
    Abboud, Joseph A.
    Parks, Brent G.
    Murthi, Anand M.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (11):
  • [10] New Solution for Massive, Irreparable Rotator Cuff Tears: The Subacromial "Biodegradable Spacer"
    Savarese, Eugenio
    Romeo, Rocco
    [J]. ARTHROSCOPY TECHNIQUES, 2012, 1 (01): : E69 - E74