Surface modification of carbon quantum dots by fluorescein derivative for dual-emission ratiometric fluorescent hypochlorite biosensing and in vivo bioimaging

被引:42
|
作者
Yan, Fanyong [1 ]
Bai, Zhangjun [1 ]
Ma, Tengchuang [2 ]
Sun, Xiaodong [1 ]
Zu, Fanlin [1 ]
Luo, Yunmei [3 ,4 ]
Chen, Liang [5 ]
机构
[1] Tianjin Polytech Univ, Coll Environm & Chem Engn, Tianjin Engn Ctr Safety Evaluat Water Qual & Safe, State Key Lab Separat Membranes & Membrane Proc, Tianjin 300387, Peoples R China
[2] Harbin Med Univ, Canc Hosp, Dept Nucl Med, Harbin 150081, Heilongjiang, Peoples R China
[3] Zunyi Med Univ, Minist Educ, Key Lab Basic Pharmacol, Zunyi 563003, Peoples R China
[4] Zunyi Med Univ, Joint Int Res Loboratory Ethnomed, Minist Educ, Zunyi 563003, Peoples R China
[5] Hokkaido Univ, Grad Sch Life Sci, Sapporo, Hokkaido 0010024, Japan
基金
中国国家自然科学基金;
关键词
Carbon quantum dots; Surface modification; Dual-emission; Hypochlorite; Biosensing; Bioimaging; SENSITIVE DETECTION; AQUEOUS-SOLUTION; RATIONAL DESIGN; REACTIVE OXYGEN; RAPID DETECTION; PROBE; ACID; CHEMOSENSOR; GLUTATHIONE; MECHANISMS;
D O I
10.1016/j.snb.2019.126638
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Surface modification of carbon quantum dots by fluorescein (FH-GA-CQDs) were synthesized for dual-emission ratiometric fluorescent ClO- biosensing and in vivo bioimaging. In the presence of ClO-, FH-GA-CQDs solution shows gradually decrease in the emission intensity at 413 nm and rapidly increase in the emission at 508 nm, corresponding to the blue-to-green emission color change. The detection mechanism is that the ClO- induces the ring-opening of FH units to form an oxadiazole structure, resulting in energy transferring from CQDs moiety to FH units. The energy transfer efficiency and energy transfer rate were estimated as 0.34 and 4.00 x 10(-7) s(-1), respectively. The results reveal that the FH-GA-CQDs have high sensitivity and selectivity for ClO- in the linear range extending from 0 to 70 mu M with a detection limit as low as 93 nM. Meanwhile, the potency of the FH-GA-CQDs detecting ClO- in real water examples were validated by recoveries from 94% to 106% and semi-quantification determination of ClO- on fluorescent test strips. Most importantly, FH-GA-CQDs display low cytotoxicity and were successfully applied for sensing of ClO- in living cells and imaging of ClO- in nude mice.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Surface modification and ratiometric fluorescence dual function enhancement for visual and fluorescent detection of glucose based on dual-emission quantum dots hybrid
    Hao, Tongfan
    Wei, Xiao
    Nie, Yijing
    Xu, Yeqing
    Lu, Kai
    Yan, Yongsheng
    Zhou, Zhiping
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 230 : 70 - 76
  • [2] Carbon dots-based dual-emission ratiometric fluorescent sensors for fluorescence and visual detection of hypochlorite and Cu2+
    Guo, Beibei
    Wang, Dinghai
    Wang, Minhui
    Tang, Yecang
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 318
  • [3] Synthesis of dual-emission fluorescent carbon quantum dots and their ratiometric fluorescence detection for arginine in 100% water solution
    Wang, Yuying
    Liu, Hanxiao
    Song, Huanhuan
    Yu, Mingming
    Wei, Liuhe
    Li, Zhanxian
    NEW JOURNAL OF CHEMISTRY, 2019, 43 (33) : 13234 - 13239
  • [4] Recent advances in dual-emission ratiometric fluorescence probes for chemo/biosensing and bioimaging of biomarkers
    Gui, Rijun
    Jin, Hui
    Bu, Xiangning
    Fu, Yongxin
    Wang, Zonghua
    Liu, Qingyun
    COORDINATION CHEMISTRY REVIEWS, 2019, 383 : 82 - 103
  • [5] Two-Photon Semiconducting Polymer Dots with Dual-Emission for Ratiometric Fluorescent Sensing and Bioimaging of Tyrosinase Activity
    Sun, Junyong
    Mel, Han
    Wang, Sufan
    Gao, Feng
    ANALYTICAL CHEMISTRY, 2016, 88 (14) : 7372 - 7377
  • [6] Ratiometric determination of Cr(VI) based on a dual-emission fluorescent nanoprobe using carbon quantum dots and a smartphone app
    Yao, Chixuan
    Liu, Qingrun
    Zhao, Ning
    Liu, Jing-Min
    Fang, Guozhen
    Wang, Shuo
    MICROCHIMICA ACTA, 2021, 188 (03)
  • [7] Ratiometric determination of Cr(VI) based on a dual-emission fluorescent nanoprobe using carbon quantum dots and a smartphone app
    Chixuan Yao
    Qingrun Liu
    Ning Zhao
    Jing-Min Liu
    Guozhen Fang
    Shuo Wang
    Microchimica Acta, 2021, 188
  • [8] Dual-Emission Carbon Dots for Fluorescent Sensing of Permanganate
    Zhu, Panpan
    Tan, Kejun
    ACS APPLIED NANO MATERIALS, 2023, 6 (22) : 21194 - 21200
  • [9] Dual-Emission Ratiometric Fluorescent Probe Based on Lanthanide-Functionalized Carbon Quantum Dots for White Light Emission and Chemical Sensing
    Li, Ying
    Wang, Ya-Qi
    Liu, Dan
    Gao, Yu
    Wang, Sai-Nan
    Qiu, Hanxun
    ACS OMEGA, 2021, 6 (22): : 14629 - 14638
  • [10] Nanomaterial-Based Dual-Emission Ratiometric Fluorescent Sensors for Biosensing and Cell Imaging
    Zhang, Yanan
    Hou, Dajun
    Wang, Zelong
    Cai, Ning
    Au, Chaktong
    POLYMERS, 2021, 13 (15)