Standardization of a UV LED Peak Wavelength, Emission Spectrum, and Irradiance Measurement and Comparison Protocol

被引:7
|
作者
Sholtes, Kari [1 ]
Keliher, Ryan [1 ]
Linden, Karl G. [1 ]
机构
[1] Univ Colorado, Dept Civil Environm & Architectural Engn, Boulder, CO 80309 USA
关键词
DOSE DETERMINATION;
D O I
10.1021/acs.est.9b02567
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Standard protocols for the measurement of irradiance, peak wavelength, and emission spectra have not yet been established for UV LED devices. This lack of standardization creates an uneven field for comparison between products. A detailed protocol was developed and tested in 14 facilities spanning manufacturers of UV LEDs and devices and research institutions in seven different countries. This protocol includes equipment calibration specifications, methods for the measurement and comparison calculations of irradiance and emission spectra, methods for the determination of peak wavelength, quality control and quality assurance steps, and industry-wide tolerances to error for each type of measurement. Measurements of the same source by operators using different equipment resulted in 2-10x the error found when measurement equipment provided as part of the study was used by each participant. The data were used to identify outliers, determine prediction intervals, and define acceptable tolerances to error. With this protocol, manufacturers have a means to report their UV LED specifications with verifiable quality control and quality assurance steps. The protocol and data generated from this study will create more confidence in the industry and standardize the comparison of UV LEDs by consumers, researchers, designers, and regulators.
引用
收藏
页码:9755 / 9763
页数:9
相关论文
共 13 条
  • [1] MEASUREMENT OF IRRADIANCE OF UV SOURCES BY COMPARISON WITH SYNCHROTRON RADIATION
    KAASE, H
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1975, 8 (07): : 590 - 592
  • [2] Spectrum Measurement of Variable Irradiance Controlled LED-Based Solar Simulator
    Esen, Vedat
    Saglam, Safak
    Oral, Bulent
    Esen, Ozge Ceylan
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2020, 10 (01): : 109 - 116
  • [3] Low-cost LED UV source with power and wavelength variable emission
    Garcia-Medina, Yazmin D.
    Reyes, Miguel
    Hernandez-Diaz, Pablo A.
    Gonzalez-Yebra, B.
    Gutierrez-Herrera, Enoch
    Alfaro-Gomez, Mariana
    LIGHT-EMITTING DEVICES, MATERIALS, AND APPLICATIONS XXVI, 2022, 12022
  • [4] Investigation of Multi-Wavelength Effect During the Measurement of UV-Enhanced Film's Emission Spectrum
    Liu Meng
    Ni Zheng-ji
    Zhang Da-wei
    Huang Yuan-shen
    Zhuang Song-lin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (09) : 2543 - 2546
  • [5] Comparison of absolute spectral irradiance responsivity measurement techniques using wavelength-tunable lasers
    Ahtee, Ville
    Brown, Steven W.
    Larason, Thomas C.
    Lykke, Keith R.
    Ikonen, Erkki
    Noorma, Mart
    APPLIED OPTICS, 2007, 46 (20) : 4228 - 4236
  • [6] Comparison of Two Measurement Methods for the Emission of Radiated Disturbances Generated by LED Drivers
    Kurylo, Kazimierz
    Sabat, Wieslaw
    Klepacki, Dariusz
    Kamuda, Kazimierz
    ENERGIES, 2022, 15 (24)
  • [7] Effect of p-GaN Spacer Layer on Emission Spectrum of Yellow-green Dual Wavelength LED
    p-GaN插入层调控InGaN基黄绿双波长LED发光光谱
    Zhang, Jian-Li (yilu.yang@yahoo.com.cn), 1600, Editorial Office of Chinese Optics (41): : 146 - 152
  • [8] UV-LED irradiation reduces the infectivity of herpes simplex virus type 1 by targeting different viral components depending on the peak wavelength
    Bui, Thi Kim Ngan
    Mawatari, Kazuaki
    Emoto, Takahiro
    Fukushima, Shiho
    Shimohata, Takaaki
    Uebanso, Takashi
    Akutagawa, Masatake
    Kinouchi, Yohsuke
    Takahashi, Akira
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 2022, 228
  • [9] The UV-A and visible solar irradiance spectrum:: inter-comparison of absolutely calibrated, spectrally medium resolution solar irradiance spectra from balloon- and satellite-borne measurements
    Gurlit, W
    Bösch, H
    Bovensmann, H
    Burrows, JP
    Butz, A
    Camy-Peyret, C
    Dorf, M
    Gerilowski, K
    Lindner, A
    Noël, S
    Platt, U
    Weidner, F
    Pfeilsticker, K
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2005, 5 : 1879 - 1890
  • [10] Comparison of emission measurement methods for electromagnetic disturbances in the frequency range from 30 MHz to 300 MHz for LED lamps according to EN 55015
    Kamuda K.
    Klepacki D.
    Kuryło K.
    Sabat W.
    Periodica polytechnica Electrical engineering and computer science, 2019, 63 (02): : 106 - 111