Integrated circuit biosensors using living whole-cell bioreporters

被引:26
|
作者
Islam, Syed K. [1 ]
Vijayaraghavan, Rajagopal
Zhang, Mo
Ripp, Steven
Caylor, Sam D.
Weathers, Brandon
Moser, Scott
Terry, Stephen
Blalock, Benjamin J.
Sayler, Gary S.
机构
[1] Univ Tennessee, Dept Elect & Comp Engn, Knoxville, TN 37996 USA
[2] Univ Tennessee, Ctr Environm Biotechnol, Knoxville, TN 37996 USA
基金
美国国家航空航天局;
关键词
bioluminescent bioreporter integrated circuit (BBIC); bioreporters; CMOS photodetectors; microluminometer; whole-cell biosensors;
D O I
10.1109/TCSI.2006.887982
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A low-power CMOS bioluminescent bioreporter integrated circuit (BBIC) is designed and fabricated for use in electronic/biological chemical sensing. The bioreporters are placed on a CMOS integrated circuit (IC) that detects bioluminescence, performs signal processing and produces a digital output pulse with a frequency that is proportional to the concentration of the target substance. The digital output pulse that contains the sensor information can then be transmitted to a remote location either wirelessly or via a data cable. The basic building blocks of the integrated circuit are the microlumninometer and the transmitter. The microluminometer includes an integrated photodetector and a signal processor and is housed in a rugged inexpensive package that can be used in many remote applications in hazardous environmental monitoring. The total power consumption of the entire signal processing circuitry including the photodiodes is 3 mW from a 3.3-V power supply. This is lowered by a factor of 3 when compared to previous versions of the BBIC. In addition, it also integrates all features of detection, processing and data transmission into one small element. The bioreporter typically contains the luxCDABE reporter genes. The close proximity of the bioreporter and the sensing element eliminates the need for complex instrumentation to channel light from the bioreporters to the microluminometer. This paper presents an integrated CMOS microluminometer realized in 0.35-mu m CMOS process and optimized for the detection of low-level bioluminescence as part of the BBIC. A flow-through test system was designed to expose the BBIC system composed of the microluminometer and the bioreporter Pseudomonas fluorescens 5RL to salicylate for determination of analytical benchmark data. The results obtained from the experiment are currently being used to study enclosures and micro-environment configurations for field-deployable BBICs for environmental monitoring.
引用
收藏
页码:89 / 98
页数:10
相关论文
共 50 条
  • [1] Construction of cadmium whole-cell biosensors and circuit amplification
    Jia, Xiaoqiang
    Liu, Teng
    Ma, Yubing
    Wu, Kang
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2021, 105 (13) : 5689 - 5699
  • [2] Construction of cadmium whole-cell biosensors and circuit amplification
    Xiaoqiang Jia
    Teng Liu
    Yubing Ma
    Kang Wu
    Applied Microbiology and Biotechnology, 2021, 105 : 5689 - 5699
  • [3] Whole-cell living biosensors - are they ready for environmental application?
    Harms, H
    Wells, MC
    van der Meer, JR
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2006, 70 (03) : 273 - 280
  • [4] Whole-cell living biosensors—are they ready for environmental application?
    Hauke Harms
    Mona C. Wells
    Jan Roelof van der Meer
    Applied Microbiology and Biotechnology, 2006, 70 : 273 - 280
  • [5] Whole-Cell Bioreporters for the Detection of Bioavailable Metals
    Hynninen, Anu
    Virta, Marko
    WHOLE CELL SENSING SYSTEMS II: APPLICATIONS, 2010, 118 : 31 - 63
  • [6] Genetically-engineered whole-cell bioreporters on integrated circuits for environmental monitoring
    Bull, N. D.
    Islam, S. K.
    Blalock, B. J.
    Ripp, S.
    Moser, S.
    Sayler, G. S.
    PROCEEDINGS OF 2008 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-10, 2008, : 1998 - +
  • [7] Genetically modified whole-cell bioreporters for environmental assessment
    Xu, Tingting
    Close, Dan M.
    Sayler, Gary S.
    Ripp, Steven
    ECOLOGICAL INDICATORS, 2013, 28 : 125 - 141
  • [8] Whole-cell bioreporters for evaluating petroleum hydrocarbon contamination
    Jiang, Bo
    Song, Yizhi
    Liu, Zengjun
    Huang, Wei E.
    Li, Guanghe
    Deng, Songqiang
    Xing, Yi
    Zhang, Dayi
    CRITICAL REVIEWS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2021, 51 (03) : 272 - 322
  • [9] WHOLE-CELL BASED BIOSENSORS
    HICKMAN, JJ
    FOSTER, KE
    KOWTHA, V
    BEY, P
    STENGER, DA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 76 - BTEC
  • [10] Whole-cell aquatic biosensors
    Evgeni Eltzov
    Robert S. Marks
    Analytical and Bioanalytical Chemistry, 2011, 400 : 895 - 913