Normal values and standardization of parameters in nuclear cardiology: Japanese Society of Nuclear Medicine working group database

被引:79
|
作者
Nakajima, Kenichi [1 ]
Matsumoto, Naoya [2 ]
Kasai, Tokuo [3 ]
Matsuo, Shinro [1 ]
Kiso, Keisuke [4 ]
Okuda, Koichi [5 ]
机构
[1] Kanazawa Univ Hosp, Dept Nucl Med, 13-1 Takara Machi, Kanazawa, Ishikawa 9208641, Japan
[2] Nihon Univ Hosp, Dept Cardiol, Tokyo, Japan
[3] Tokyo Med Univ, Hachioji Med Ctr, Dept Cardiol, Tokyo 1608402, Japan
[4] Natl Cerebral & Cardiovasc Ctr, Dept Radiol, Suita, Osaka, Japan
[5] Kanazawa Med Univ, Dept Phys, Uchinada, Ishikawa 92002, Japan
关键词
Japanese Society of Nuclear Medicine ([!text type='JS']JS[!/text]NM) working group; Normal database; Myocardial perfusion imaging; I-123-Metaiodobenzylguanidine (MIBG) quantification; MYOCARDIAL-PERFUSION SPECT; CORONARY-ARTERY-DISEASE; CHRONIC HEART-FAILURE; TO-MEDIASTINUM RATIOS; PROGNOSTIC VALUE; PHASE-ANALYSIS; EJECTION FRACTION; GATED SPECT; RISK STRATIFICATION; IMAGING PROTOCOL;
D O I
10.1007/s12149-016-1065-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
As a 2-year project of the Japanese Society of Nuclear Medicine working group activity, normal myocardial imaging databases were accumulated and summarized. Stress-rest with gated and non-gated image sets were accumulated for myocardial perfusion imaging and could be used for perfusion defect scoring and normal left ventricular (LV) function analysis. For single-photon emission computed tomography (SPECT) with multi-focal collimator design, databases of supine and prone positions and computed tomography (CT)-based attenuation correction were created. The CT-based correction provided similar perfusion patterns between genders. In phase analysis of gated myocardial perfusion SPECT, a new approach for analyzing dyssynchrony, normal ranges of parameters for phase bandwidth, standard deviation and entropy were determined in four software programs. Although the results were not interchangeable, dependency on gender, ejection fraction and volumes were common characteristics of these parameters. Standardization of I-123-MIBG sympathetic imaging was performed regarding heart-to-mediastinum ratio (HMR) using a calibration phantom method. The HMRs from any collimator types could be converted to the value with medium-energy comparable collimators. Appropriate quantification based on common normal databases and standard technology could play a pivotal role for clinical practice and researches.
引用
收藏
页码:188 / 199
页数:12
相关论文
共 50 条
  • [1] Normal values and standardization of parameters in nuclear cardiology: Japanese Society of Nuclear Medicine working group database
    Kenichi Nakajima
    Naoya Matsumoto
    Tokuo Kasai
    Shinro Matsuo
    Keisuke Kiso
    Koichi Okuda
    Annals of Nuclear Medicine, 2016, 30 : 188 - 199
  • [2] The validity of multi-center common normal database for identifying myocardial ischemia: Japanese Society of Nuclear Medicine working group database
    Kenichi Nakajima
    Shinro Matsuo
    Masaya Kawano
    Naoya Matsumoto
    Jun Hashimoto
    Keiichiro Yoshinaga
    Junichi Taki
    Koichi Okuda
    Annals of Nuclear Medicine, 2010, 24 : 99 - 105
  • [3] The validity of multi-center common normal database for identifying myocardial ischemia: Japanese Society of Nuclear Medicine working group database
    Nakajima, Kenichi
    Matsuo, Shinro
    Kawano, Masaya
    Matsumoto, Naoya
    Hashimoto, Jun
    Yoshinaga, Keiichiro
    Taki, Junichi
    Okuda, Koichi
    ANNALS OF NUCLEAR MEDICINE, 2010, 24 (02) : 99 - 105
  • [4] Creation and characterization of japanese standards for myocardial perfusion SPECT: Database from the Japanese society of nuclear medicine working group
    Nakajima, Kenichi
    Kumita, Shinichiro
    Ishida, Yoshio
    Momose, Mitsuru
    Hashimoto, Jun
    Morita, Koichi
    Taki, Junichi
    Yamashina, Shohei
    Maruno, Hirotaka
    Ogawa, Masami
    Kubota, Masahiro
    Takahashi, Munehiro
    Odagawa, Tetsuro
    Yokozuka, Koichi
    ANNALS OF NUCLEAR MEDICINE, 2007, 21 (09) : 505 - 511
  • [5] Creation and characterization of Japanese standards for myocardial perfusion SPECT: database from the Japanese Society of Nuclear Medicine Working Group
    Kenichi Nakajima
    Shinichiro Kumita
    Yoshio Ishida
    Mitsuru Momose
    Jun Hashimoto
    Koichi Morita
    Junichi Taki
    Shohei Yamashina
    Hirotaka Maruno
    Masami Ogawa
    Masahiro Kubota
    Munehiro Takahashi
    Tetsuro Odagawa
    Koichi Yokozuka
    Annals of Nuclear Medicine, 2007, 21 : 505 - 511
  • [6] STANDARDIZATION OF NUCLEAR-MEDICINE METHODS IN CARDIOLOGY
    BELLINA, CR
    BIGGI, A
    BISI, G
    CAMUZZINI, GF
    CASTELLANO, GC
    FARINELLI, C
    GALLI, G
    GUZZARDI, R
    INGLESE, E
    MAINI, CL
    MARZULLO, P
    MORELLO, P
    TALLIA, R
    TURCO, GL
    VALLE, G
    JOURNAL OF NUCLEAR MEDICINE AND ALLIED SCIENCES, 1986, 30 (2-3): : 73 - 115
  • [7] REPORT OF THE WORKING GROUP NUCLEAR CARDIOLOGY
    SECHTEM, U
    ZEITSCHRIFT FUR KARDIOLOGIE, 1995, 84 (07): : 575 - 576
  • [8] Comparison of phase dyssynchrony analysis using gated myocardial perfusion imaging with four software programs: Based on the Japanese Society of Nuclear Medicine working group normal database
    Kenichi Nakajima
    Koichi Okuda
    Shinro Matsuo
    Keisuke Kiso
    Seigo Kinuya
    Ernest V. Garcia
    Journal of Nuclear Cardiology, 2017, 24 : 611 - 621
  • [9] Comparison of phase dyssynchrony analysis using gated myocardial perfusion imaging with four software programs: Based on the Japanese Society of Nuclear Medicine working group normal database
    Nakajima, Kenichi
    Okuda, Koichi
    Matsuo, Shinro
    Kiso, Keisuke
    Kinuya, Seigo
    Garcia, Ernest V.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (02) : 611 - 621
  • [10] Working group on nuclear cardiology and magnetic resonance
    Sechtem, U
    Underwood, R
    EUROPEAN HEART JOURNAL, 1996, 17 (12) : 1916 - 1917