A Wide-Band Digital Lock-In Amplifier and Its Application in Microfluidic Impedance Measurement

被引:23
|
作者
Huang, Kan [1 ]
Geng, Yangye [2 ]
Zhang, Xibin [1 ]
Chen, Dihu [1 ]
Cai, Zhigang [1 ]
Wang, Min [3 ]
Zhu, Zhen [2 ]
Wang, Zixin [1 ]
机构
[1] Sun Yat Sen Univ, Sch Elect & Informat Technol, Xingang Xi Rd 135, Guangzhou 510275, Guangdong, Peoples R China
[2] Southeast Univ, Sch Elect Sci & Engn, Key Lab MEMS, Minist Educ, Sipailou 2, Nanjing 210096, Jiangsu, Peoples R China
[3] Chinese Acad Sci, Guangzhou Inst Geochem, Kehua St 511, Guangzhou 510640, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
digital lock-in amplifier; wide-band; fully differential analog circuit; reconfigurable hardware; electrical impedance spectroscopy;
D O I
10.3390/s19163519
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, we report on the design of a wide-band digital lock-in amplifier (DLIA) of up to 65 MHz and its application for electrical impedance measurements in microfluidic devices. The DLIA is comprised of several dedicated technologies. First, it features a fully differential analog circuit, which includes a preamplifier with a low input noise of 4.4 nV/root Hz, a programmable-gain amplifier with a gain of 52 dB, and an anti-aliasing, fully differential low-pass filter with -76 dB stop-band attenuation. Second, the DLIA has an all-digital phase lock loop, which features a phase deviation of less than 0.02 degrees throughout the frequency range. The phase lock loop utilizes an equally accurate period-frequency measurement, with a sub-ppm precision of frequency detection. Third, a modified clock link is implemented in the DLIA to improve the signal-to-noise ratio of the analog-to-digital converter affected by clock jitter of up to 20 dBc. A series of measurements were performed to characterize the DLIA, and the results showed an accurate performance. Additionally, impedance measurements of standard-size microparticles were performed by frequency sweep from 300 kHz to 30 MHz, using the DLIA in a microfluidic device. Different diameters of microparticle could be accurately distinguished according to the relative impedance at 2.5 MHz. The results confirm the promising applications of the DLIA in microfluidic electrical impedance measurements.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] The Simulation and Implementation of Digital Lock-in Amplifier Application to Measuring Cell Impedance Spectrum
    Wang, S. F.
    Wang, S. K.
    Ma, C.
    INTERNATIONAL CONFERENCE ON ADVANCED EDUCATIONAL TECHNOLOGY AND INFORMATION ENGINEERING (AETIE 2015), 2015, : 637 - 643
  • [2] BROAD-BAND DIGITAL LOCK-IN AMPLIFIER TECHNIQUES
    DIXON, PK
    WU, L
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (10): : 3329 - 3336
  • [3] Digital lock-in amplifier controlled by FPGA for spectral measurement
    Zhang L.
    Cao Z.
    Zhong Q.
    Huang Y.
    Yuan Z.
    Huang J.
    Qi G.
    Pan W.
    Lu X.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2023, 52 (10):
  • [4] Low-Power Lock-In Amplifier for Complex Impedance Measurement
    Xu, Jiawei
    Meynants, Guy
    Merken, Patrick
    2009 3RD INTERNATIONAL WORKSHOP ON ADVANCES IN SENSORS AND INTERFACES, 2009, : 104 - +
  • [5] An Embedded Impedance Measurement for DC Microgrids Based on a Lock-In Amplifier
    Paz, Francisco
    Ordonez, Martin
    2016 IEEE 7TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG), 2016,
  • [6] Implementation of Digital Lock-in Amplifier
    Bhattacharyya, Sabyasachi
    Ahmed, Ragib Nasir
    Purkayastha, Basab Bijoy
    Bhattacharyya, Kaustubh
    XXVII IUPAP CONFERENCE ON COMPUTATIONAL PHYSICS (CCP2015), 2016, 759
  • [7] Application of digital lock-in amplifier in nonlinear ultrasonic inspection
    Zhu, Chuanyu
    Ma, Guanbing
    Shen, ShaoBin
    Lei, Yikun
    Huang, Songhua
    IEEE INTERNATIONAL CONFERENCE ON RECENT ADVANCES IN SYSTEMS SCIENCE AND ENGINEERING (IEEE RASSE 2021), 2021,
  • [8] Software Digital Lock-in Amplifier in the application of fNIRS System
    Yin Xuxian
    Xu Baolei
    Wang Zhidong
    Li Hongyi
    Shi Gang
    MEASUREMENT TECHNOLOGY AND ENGINEERING RESEARCHES IN INDUSTRY, PTS 1-3, 2013, 333-335 : 535 - +
  • [9] SIMULATION OF A DIGITAL LOCK-IN AMPLIFIER
    DENING, DC
    JOURNAL OF MAGNETIC RESONANCE, 1976, 23 (03) : 461 - 463
  • [10] A VERY HIGH IMPEDANCE WIDE-BAND BUFFER AMPLIFIER
    BARKER, RWJ
    HART, BL
    PROCEEDINGS OF THE IEEE, 1969, 57 (02) : 244 - &