Breast cancer detection based on CPW antenna

被引:4
|
作者
Slimi, Marwa [1 ]
Jmai, Bassem [1 ,2 ]
Mendes, Paulo [2 ]
Gharsallah, Ali [1 ]
机构
[1] Univ Tunis El Manar, Dept Phys, Microwave Elect Res Lab, FST, Tunis, Tunisia
[2] Univ Minh, Microelectromech Syst Res Unit, Guimaraes, Portugal
关键词
Breast phantom; CPW antenna; breast cancer detection;
D O I
10.1109/mms48040.2019.9157301
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work presents the design of CPW antenna for microwave tumor cell detection. The simulation results of the antenna performance in free space using CST-MWS are shown at 4.5 GHz. In order to study, the influence of the antenna movement on its electrical properties during breast cancer diagnosis, the CPW antenna is placed at a distance of 32 mm from the surface of the breast phantom with and without tumor cells by using different positions of the antenna to cover the entire breast surface and with various cross sections of the breast phantom. The tumor is represented by the sphere of diameter equal to 10 mm. In this paper, three interesting antenna parameters are analyzed, the return loss, the radiation pattern and the E-field inside the breast. This study shows good results to can detect the incidence of the tumor at 4 GHz. Comparing these results without and with tumor, it can be said that increasing the angle between the antenna and the breast phantom (from 0 degrees to 60 degrees), the return loss increases from -17 dB to -19.34 dB in 0 degrees, from - 15.37 dB to -19.28 dB in 30 degrees and from -12.18 dB to -15.44 dB in 60 degrees. The gain increases from 4.22 dB to 4.26 dB in 0 degrees, from 1.13 dB to 1.2 dB in 30 degrees and from 3.91 dB to 4.06 dB in 60 degrees. In addition, to the increase of the e-field values inside the different cross sections of the breast phantom.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Flexible Microstrip CPW Slated Antenna for Breast Cancer Detection
    Afyf, Amal
    Bellarbi, Larbi
    Errachid, Abdelhamid
    Adel Sennouni, M.
    PROCEEDINGS OF 2015 INTERNATIONAL CONFERENCE ON ELECTRICAL AND INFORMATION TECHNOLOGIES (ICEIT 2015), 2015, : 292 - 295
  • [2] Miniaturized Wideband Flexible CPW Antenna with Hexagonal Ring Slots for Early Breast Cancer Detection
    Amal, Afyf
    Larbi, Bellarbi
    Anouar, Achour
    Fatima, Riouch
    Abdelhamid, Errachid
    ADVANCES IN UBIQUITOUS NETWORKING, 2016, 366 : 211 - 222
  • [3] Resonator based antenna sensor for breast cancer detection
    Rao P.K.
    Mishra R.
    Progress In Electromagnetics Research M, 2021, 101 : 149 - 159
  • [4] Resonator Based Antenna Sensor for Breast Cancer Detection
    Rao, Praveen K.
    Mishra, Rajan
    PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2021, 101 : 149 - 159
  • [5] Textile based antenna design for breast cancer detection
    Banu, S. M. Asha
    Jeyanthi, K. Meena Alias
    MATERIALS TODAY-PROCEEDINGS, 2022, 62 : 4814 - 4820
  • [6] ISM band CPW-fed antenna for detection of skin cancer
    Prasad, Devu Jagadish Chandra
    Kiran, Kalepalli Venkata Ravi
    Syamala, Neeli
    Kumar, Bandi Kiran
    Babu, Kamili Jagadeesh
    Prasad, D. Shyam
    JOURNAL OF INSTRUMENTATION, 2024, 19 (09):
  • [7] Compact antenna for radar-based breast cancer detection
    Yun, X
    Fear, EC
    Johnston, RH
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2005, 53 (08) : 2374 - 2380
  • [8] Metamerial-Based Monopole Antenna For Breast Cancer Detection
    Asok, Athul O.
    Vidhya, J. S.
    Babu, Fibin Bethel
    Dey, Sukomal
    Kunju, Nissan
    2022 IEEE 19TH INDIA COUNCIL INTERNATIONAL CONFERENCE, INDICON, 2022,
  • [9] Microwave Imaging for Breast Tumor Detection Using Uniplanar AMC Based CPW-Fed Microstrip Antenna
    Mahmud, Md Zulfiker
    Islam, Mohammad Tariqul
    Misran, Norbahiah
    Kibria, Salehin
    Samsuzzaman, Md
    IEEE ACCESS, 2018, 6 : 44763 - 44775
  • [10] An Extensive Survey on Metamaterial Based Antenna Design for Breast Cancer Detection
    Asha, Banu S. M.
    Meena, Alias Jeyanthi K.
    JOURNAL OF COMPLEMENTARY MEDICINE RESEARCH, 2020, 11 (01): : 233 - 240