Development and calibration of real-time PCR for quantification of airborne microorganisms in air samples

被引:67
|
作者
An, Hey Reoun
Mainelis, Gediminas
White, Lori
机构
[1] Rutgers State Univ, Dept Environm Studies, New Brunswick, NJ 08901 USA
[2] Rutgers State Univ, Dept Biochem & Microbiol, New Brunswick, NJ 08901 USA
关键词
bioaerosol quantification; real-time PCR; standard curves; air sampling; bioaerosols;
D O I
10.1016/j.atmosenv.2006.07.020
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This manuscript describes the coupling of bioaerosol collection and the use of real-time PCR (RT-PCR) to quantify the airborne bacteria. The quantity of collected bacteria determined by RT-PCR is compared with conventional quantification techniques, such as culturing, microscopy and airborne microorganism counting by using optical particle counter (OPC). Our data show that an experimental approach used to develop standard curves for use with RT-PCR is critical for accurate sample quantification. Using universal primers we generated 12 different standard curves which were used to quantify model organism Escherichia coli (Migula) Catellani from air samples. Standard curves prepared using a traditional approach, where serially diluted genomic DNA extracted from pure cultured bacteria were used in PCR reaction as a template DNA yielded significant underestimation of sample quantities compared to airborne microorganism concentration as measured by an OPC. The underestimation was especially pronounced when standard curves were built using colony forming units (CFUs). In contrast, the estimate of cell concentration in an air sample by RT-PCR was more accurate (similar to 60% compared to the airborne microorganism concentration) when the standard curve was built using aerosolized E. coli. The accuracy improved even further (similar to 100%) when air samples used to build the standard curves were diluted first, then the DNA extracted from each dilution was amplified by the RT-PCR-to mimic the handling of air samples with unknown and possibly low concentration. Therefore, our data show that standard curves used for quantification by RT-PCR needs to be prepared using the same environmental matrix and procedures as handling of the environmental sample in question. Reliance on the standard curves generated with cultured bacterial suspension (a traditional approach) may lead to substantial underestimation of microorganism quantities in environmental samples. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:7924 / 7939
页数:16
相关论文
共 50 条
  • [1] Development and evaluation of a method for the quantification of airborne Thermoactinomyces vulgaris by real-time PCR
    Betelli, Laetitia
    Duquenne, Philippe
    Grenouillet, Frederic
    Simon, Xavier
    Scherer, Emeline
    Gain, Evelyne
    Hartmann, Alain
    JOURNAL OF MICROBIOLOGICAL METHODS, 2013, 92 (01) : 25 - 32
  • [2] Looking into the Quantification of Forensic Samples with Real-Time PCR
    Ricci, Ugo
    Ciappi, Dario
    Carboni, Ilaria
    Centrone, Claudia
    Giotti, Irene
    Petti, Martina
    Alice, Brogi
    Pelo, Elisabetta
    GENES, 2024, 15 (06)
  • [3] Detection of Airborne Juniperus Pollen By Conventional and Real-Time PCR from Burkard Air Samples
    Mohanty, Rashmi Prava
    Buchheim, Mark A.
    Anderson, James
    Levetin, Estelle
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2015, 135 (02) : AB231 - AB231
  • [4] DNA quantification by real-time PCR in different forensic samples
    Martins, C.
    Lima, G.
    Carvalho, M. R.
    Caine, L.
    Porto, M. J.
    FORENSIC SCIENCE INTERNATIONAL GENETICS SUPPLEMENT SERIES, 2015, 5 : E545 - E546
  • [5] Development and evaluation of a real-time PCR assay for quantification of Giardia and Cryptosporidium in sewage samples
    Alonso, Jose L.
    Amoros, Inmaculada
    Canigral, Irene
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2011, 89 (04) : 1203 - 1211
  • [6] Development and evaluation of a real-time PCR assay for quantification of Giardia and Cryptosporidium in sewage samples
    José L. Alonso
    Inmaculada Amorós
    Irene Cañigral
    Applied Microbiology and Biotechnology, 2011, 89 : 1203 - 1211
  • [7] Quantification of enterococci and human adenoviruses in environmental samples by real-time PCR
    He, JW
    Jiang, S
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2005, 71 (05) : 2250 - 2255
  • [8] Detection and quantification of Mycobacterium leprae in tissue samples by real-time PCR
    Stefanie Kramme
    Gisela Bretzel
    Marcus Panning
    Joseph Kawuma
    Christian Drosten
    Medical Microbiology and Immunology, 2004, 193 : 189 - 193
  • [9] Detection and quantification of Mycobacterium leprae in tissue samples by real-time PCR
    Kramme, S
    Bretzel, G
    Panning, M
    Kawuma, J
    Drosten, C
    MEDICAL MICROBIOLOGY AND IMMUNOLOGY, 2004, 193 (04) : 189 - 193
  • [10] Quantification of Clostridium difficile by real-time PCR in hospital environmental samples
    Nonnenmacher, C.
    Kropatsch, R.
    Schumacher, S.
    Mutters, R.
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2007, 29 : S190 - S191