Rebinning and reconstruction techniques for 3D TOF-PET

被引:13
|
作者
Vandenberghe, Stefaan [1 ]
Karp, Joel
机构
[1] Philips Res USA, Briarcliff Manor, NY USA
[2] Univ Penn, PET Instrumentat Grp, Philadelphia, PA 19104 USA
关键词
PET; TOF-PET; reconstruction; iterative; MLEM;
D O I
10.1016/j.nima.2006.08.065
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The measured time difference in 3D Time-of-Flight (TOE) positron emission tomography (PET) makes it possible to improve the signal-to-noise ratio of reconstructed images. The improvement in signal-to-noise ratio will probably be used to reduce imaging time. To keep up with workflow there will be a need for faster reconstruction methods. A variety of reconstruction and rebinning methods have been developed in the past for 2D and 3D TOF-PET data. The TOE information makes very simple reconstruction methods possible. These allow real time reconstruction but the obtained image quality is lower. Relative fast reconstructions can be obtained using rebinning techniques. Fully 3D iterative listmode reconstruction makes no approximations but comes at the expense of long reconstruction times. Data from Monte Carlo simulations of 3D TOF-PET scanners are used to quantify differences in noise and contrast between the different methods. Real time methods are useful for direct display after or even during acquisition, but do not generate useful data for reviewing. Rebinning methods can be used to reduce the reconstruction time with a small loss in image quality and the image quality loss is quite small if good timing resolution can be achieved. Fully 3D iterative listmode reconstruction maximizes the obtained image quality and should be used if not even a small loss in image quality is acceptable. When timing resolution is improved the difference between the different methods become clearly smaller and in the limit where timing resolution is equal to spatial resolution, the methods are equivalent. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:421 / 424
页数:4
相关论文
共 50 条
  • [1] 3D TOF-PET image reconstruction using total variation regularization
    Raczynski, L.
    Wislicki, W.
    Klimaszewski, K.
    Krzemien, W.
    Kopka, P.
    Kowalski, P.
    Shopa, R. Y.
    Bala, M.
    Chhokar, J.
    Curceanu, C.
    Czerwinski, E.
    Dulski, K.
    Gajewski, J.
    Gajos, A.
    Gorgol, M.
    Del Grande, R.
    Hiesmayr, B.
    Jasinska, B.
    Kacprzak, K.
    Kaplon, L.
    Kisielewska, D.
    Korcyl, G.
    Kozik, T.
    Krawczyk, N.
    Kubicz, E.
    Mohammed, M.
    Niedzwiecki, S. Z.
    Palka, M.
    Pawlik-Niedzwiecka, M.
    Raj, J.
    Rakoczy, K.
    Rucinski, A.
    Sharma, S.
    Shivani, S.
    Silarski, M.
    Skurzok, M.
    Stepien, E. L.
    Zgardzinska, B.
    Moskal, P.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 80 : 230 - 242
  • [2] Exact rebinning methods for 3D PET
    Xuan, Liu
    Defrise, Michel
    Michel, Christian
    Sibomana, Merence
    Comtat, Claude
    Kinahan, Paul
    Townsend, David
    [J]. IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 3 : 1604 - 1609
  • [3] 3D PET reconstruction with the ECAT EXACT HR using Fourier rebinning
    Defrise, M
    Sibomana, M
    Michel, C
    Newport, D
    [J]. 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1316 - 1320
  • [4] Visualization of Raw 3D List-mode PET and TOF-PET Data Without Tomographic Reconstruction Using Virtual Space
    Sitek, Arkadiusz
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2904 - 2906
  • [5] 3D Cone-Beam Rebinning and Reconstruction for Animal PET Transmission Tomography
    Deng, Junjun
    Siegel, Stefan
    Chen, Mu
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2885 - 2888
  • [6] A new rebinning algorithm for 3D PET data
    Erlandsson, Kjell
    van Heertum, Ronald
    Mann, J. John
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3346 - 3350
  • [7] Fourier rebinning for 3D transmission scans in PET
    Becher, AJ
    Karp, JS
    Matej, S
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 178P - 178P
  • [8] Dose Optimization in TOF-PET/MR Compared to TOF-PET/CT
    Queiroz, Marcelo A.
    Delso, Gaspar
    Wollenweber, Scott
    Deller, Timothy
    Zeimpekis, Konstantinos
    Huellner, Martin
    Barbosa, Felipe de Galiza
    von Schulthess, Gustav
    Veit-Haibach, Patrick
    [J]. PLOS ONE, 2015, 10 (07):
  • [9] MAP reconstruction for Fourier rebinned TOF-PET data
    Bai, Bing
    Lin, Yanguang
    Zhu, Wentao
    Ren, Ran
    Li, Quanzheng
    Dahlbom, Magnus
    DiFilippo, Frank
    Leahy, Richard M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (04): : 925 - 949
  • [10] Data rebinning and reconstruction in 3D PET/CT oncological studies: a Monte Carlo evaluation
    Rizzo, G
    Castiglioni, I
    Russo, G
    Gilardi, MC
    Panzacchi, A
    Fazio, F
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3109 - 3112