Thermodynamic performance evaluation of a heat pump system with textile based solar air heater for heating process

被引:16
|
作者
Ural, Tolga [1 ]
Kecebas, Ali [1 ]
Guler, Onur Vahip [1 ]
机构
[1] Mugla Sitki Kocman Univ, Technol Fac, Dept Energy Syst Engn, Mugla, Turkey
关键词
Heating process; Heat pump; Solar air collector; Fabric absorber; Exergy analysis; Thermodynamic performance; THERMAL-ENERGY STORAGE; COLLECTORS; SIMULATION; EXERGY; PART;
D O I
10.1016/j.applthermaleng.2021.116905
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, a newly system is designed and tested which integrates air-to-water heat pump and solar air collector having fabric absorber for the shortcoming of frost depositing on the evaporator in heating condition. Thus, it can achieve synchronous and heat exchange in one integrated system between R410A, gaseous and liquid heat source. In addition, the system performance is evaluated in comparison with those of the standard heat pump and the flat-plate solar air collector assisted heat pump under the same climatic conditions. In this respect, experimental tests are performed for winter season and the thermodynamic inefficiencies' changes are monitored by real-time exergy analysis under climate conditions of the Mu.gla province/Turkey. This approximation allows the designer and the manufacturer to see the progress. The results of the study indicate that the textile based solar air collector assisted heat pump shows superior performance with 5.11 COP and 56% exergy efficiency when compared to the other two heat pumps. The equipment with the highest exergy destruction is determined as evaporator. In low temperatures, the problem of frost depositing on the evaporator is solved faster with the use of solar air collector. With the use of a textile-based solar air collector on heat pump, the electrical consumption of the compressor is reduced by 8.3%. Consequently, the proposed system clearly demonstrated its applicability as an independent and reliable system for the building heating process due to its benefits like energy saving, protection against environmental conditions and evaporator' anti-frost deposit behavior.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Performance analysis of heat pump based on a new solar air-source heat pump heating system
    Liang, Caihua
    Zhang, Xiaosong
    Zhu, Xia
    Li, Xiuwei
    Journal of Southeast University (English Edition), 2010, 26 (02) : 227 - 231
  • [2] COMPARATIVE STUDY OF THE PERFORMANCE OF TWO GREENHOUSE HEATING TECHNIQUES: SOLAR AIR HEATER AND HEAT PUMP
    Sellami, Douja
    Boughanmi, Hassen
    Bouadila, Salwa
    Ghorbel, Abdelwahed
    Ben Salem-Fnayou, Asma
    HEAT TRANSFER RESEARCH, 2019, 50 (12) : 1127 - 1147
  • [3] Performance evaluation of a solar energy water heater in conjunction with air source heat pump
    Luo, H. L.
    Peng, J. H.
    Zhong, H.
    Leng, T. T.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 788 - 791
  • [4] EVALUATION OF THERMAL PERFORMANCE OF AIR SOURCE HEAT PUMP HEATING SYSTEM BASED ON ELECTRICITY EQUIVALENT
    Huang, Dongsheng
    Zhang, Yin
    Zheng, Yanhong
    THERMAL SCIENCE, 2022, 26 (05): : 4207 - 4216
  • [5] Technical and economic performance study on winter heating system of air source heat pump assisted solar evacuated tube water heater
    Li, Jinping
    Wei, Shifan
    Dong, Yuhui
    Liu, Xiaomin
    Novakovic, Vojislav
    APPLIED THERMAL ENGINEERING, 2023, 221
  • [6] Study on the performance of a solar assisted air source heat pump system for building heating
    Liang, Cai-hua
    Zhang, Xiao-song
    Li, Xiu-wei
    Zhu, Xia
    ENERGY AND BUILDINGS, 2011, 43 (09) : 2188 - 2196
  • [7] Contrastive research of heating performance of direct expansion solar/air assisted heat pump system and air-source heat pump
    Ma K.
    Li X.
    Li S.
    Gao C.
    Huagong Xuebao/CIESC Journal, 2020, 71 : 375 - 381
  • [8] Thermodynamic analysis on performance of direct expansion solar assisted heat pump water heater
    Engineering Research Center of Solar Power and Refrigeration, Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240, China
    Huagong Xuebao, 2006, SUPPL. (110-115):
  • [9] Enhancement of heat transfer in a combined solar air heating and water heater system
    Kumar, P. Ganesh
    Balaji, K.
    Sakthivadivel, D.
    Vigneswaran, V. S.
    Velraj, R.
    Kim, Sung Chul
    ENERGY, 2021, 221
  • [10] Characteristic and Performance simulation of the heat pump part of a new solar assisted air-source heat pump system heating system
    Liang, Caihua
    Zhang, Xiaosong
    Zhu, Xia
    Li, Xiuwei
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 774 - 781