High-precision isotopic analysis of palmitoylcarnitine by liquid chromatography/electrospray ionization ion-trap tandem mass spectrometry

被引:6
|
作者
Guo, ZengKui
Yarasheski, Kevin
Jensen, Michael D.
机构
[1] Mayo Fdn, Endocrine Res Unit, Rochester, MN 55905 USA
[2] Washington Univ, Dept Med, St Louis, MO 63130 USA
关键词
D O I
10.1002/rcm.2753
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Single quadrupole gas chromatography/mass spectrometry (GC/MS) has been widely used for isotopic analysis in metabolic investigations using stable isotopes as tracers. However, its inherent shortcomings prohibit it from broader use, including low isotopic precision and the need for chemical derivatization of the analyte. In order to improve isotopic detection power, liquid chromatography/electrospray ionization ion-trap tandem mass spectrometry (LC/ESI-itMS2) has been evaluated for its isotopic precision and chemical sensitivity for the analysis of [C-13]palmitoylcarnitine. Over the enrichment range of 0.4-10 MPE (molar % excess), the isotopic response of LC/ESI-itMS2 to [C-13]palmitoylcarnitine was linear (r=1.00) and the average isotopic precision (standard deviation, SD) was 0.11 MPE with an average coefficient of variation (CV) of 5.6%. At the lower end of isotopic enrichments (0.4-0.9 MPE), the isotopic precision was 0.05 MPE (CV=8%). Routine analysis of rat skeletal muscle [C-13(4)]palmitoylcarnitine demonstrated an isotopic precision of 0.03 MPE for gastrocnemius (n=16) and of 0.02 MPE for tibialis anterior (n=16). The high precision enabled the detection of a small (0.08 MPE) but significant (P=0.01) difference in [C-13(4)]palmitoylcarnitine enrichments between the two muscles, 0.51 MPE (CV=5.8%) and 0.43 MPE (CV=4.6%), respectively. Therefore, the system demonstrated an isotopic lower detection limit (LDL) of <= 0.1 MPE (2 X SD) that has been impossible previously with other organic mass spectrometry instruments. LC/ESI-itMS2 systems have the potential to advance metabolic investigations using stable isotopes to a new level by significantly increasing the isotopic solving power. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:3361 / 3366
页数:6
相关论文
共 50 条
  • [1] Direct analysis of microcystins by microbore liquid chromatography electrospray ionization ion-trap tandem mass spectrometry
    Zweigenbaum, JA
    Henion, JD
    Beattie, KA
    Codd, GA
    Poon, GK
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 23 (04) : 723 - 733
  • [2] Determination of loratadine in human plasma by liquid chromatography electrospray ionization ion-trap tandem mass spectrometry
    Salem, II
    Idrees, J
    Al Tamimi, JI
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (01) : 141 - 151
  • [3] Identification of lignans by liquid chromatography-electrospray ionization ion-trap mass spectrometry
    Eklund, Patrik C.
    Backman, M. Josefin
    Kronberg, Leif A.
    Smeds, Annika I.
    Sjoholm, Rainer E.
    [J]. JOURNAL OF MASS SPECTROMETRY, 2008, 43 (01): : 97 - 107
  • [4] Identification of Glycoside Compounds from Tobacco by High Performance Liquid Chromatography/Electrospray Ionization Linear Ion-Trap Tandem Mass Spectrometry Coupled with Electrospray Ionization Orbitrap Mass Spectrometry
    Jia, Chunxiao
    Zhu, Yonghua
    Zhang, Jinjie
    Yang, Jing
    Xu, Chunping
    Mao, Duobin
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2017, 28 (04) : 629 - 640
  • [5] Elucidation of triacylglycerols in cod liver oil by liquid chromatography electrospray tandem ion-trap mass spectrometry
    Zeng, Ying-Xu
    Araujo, Pedro
    Du, Zhen-Yu
    Nguyen, Thu-Thao
    Froyland, Livar
    Grung, Bjorn
    [J]. TALANTA, 2010, 82 (04) : 1261 - 1270
  • [6] Analysis of phospholipid species in rat peritoneal surface layer by liquid chromatography/electrospray ionization ion-trap mass spectrometry
    Gao, Fei
    Tian, Xinkui
    Wen, Dawei
    Liao, Jie
    Wang, Tao
    Liu, Huwei
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR AND CELL BIOLOGY OF LIPIDS, 2006, 1761 (07): : 667 - 676
  • [7] Determination of tetrodotoxin by liquid chromatography coupled with electrospray ion-trap mass spectrometry
    Li Ai-Feng
    Yu Ren-Cheng
    Zhou Ming-Jiang
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (03) : 397 - 400
  • [8] Liquid chromatography with electrospray ion-trap mass spectrometry for the determination of yessotoxins in shellfish
    Amandi, MF
    Furey, A
    Lehane, M
    Ramstad, H
    James, KJ
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 976 (1-2) : 329 - 334
  • [9] Analysis of a commercial preparation of erythromycin estolates by tandem mass spectrometry and high performance liquid chromatography/electrospray ionization tandem mass spectrometry using an ion trap mass spectrometer
    Lai, CC
    Tsai, PL
    Yu, C
    Her, GR
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (06) : 468 - 475
  • [10] ANALYSIS OF NEUROPEPTIDES BY PERFUSION LIQUID-CHROMATOGRAPHY ELECTROSPRAY ION-TRAP MASS-SPECTROMETRY
    LIN, HY
    VOYKSNER, RD
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (04) : 333 - 338