Characterization of a triple-GEM position sensitive detector for X-ray fluorescence imaging

被引:0
|
作者
de Souza, Geovane G. A. [1 ]
da Luz, Hugo Natal [1 ]
机构
[1] Univ Sao Paulo, Inst Fis, Dept Nucl Phys, Sao Paulo, Brazil
关键词
D O I
10.1002/xrs.3068
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In this work, we characterized an X-ray position sensitive gaseous detector based in a triple stack of gas electron multipliers. The readout circuit is divided in 256 strips for each dimension and using a resistive chain interconnecting the strips, we are able to reconstruct the radiation interaction points by resistive charge division. The detector achieved gains above 10(4), energy resolution of 15.28% (full width at half maximum) for 5.9 keV X-rays, and position resolution of 1.2 mm, while operating in Ar/CO2(90/10) at atmospheric pressure.
引用
收藏
页码:387 / 394
页数:8
相关论文
共 50 条
  • [1] Characterization of the Mini-X2 X-ray Tube and sensitivity measurements of a Triple-GEM
    Tamigio, A.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2024, 47 (05):
  • [2] Characterization and calibration of a triple-GEM detector for medical dosimetry
    Velasquez Moros, Andrea
    Castro Serrato, Hector Fabio
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1000
  • [3] A complete simulation of a triple-GEM detector
    Bonivento, W
    Cardini, A
    Pinci, D
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 273 - 277
  • [4] Energy- and position-sensitive pixel detector Timepix for X-ray fluorescence imaging
    Zemlicka, Jan
    Jakubek, Jan
    Kroupa, Martin
    Tichy, Vladimir
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 202 - 204
  • [5] RADIATION DOSIMETRY WITH A TRIPLE-GEM DETECTOR
    Velasquez, Andrea
    Castro, Hector F.
    MOMENTO-REVISTA DE FISICA, 2023, (66): : 70 - 89
  • [6] Combined readout of a triple-GEM detector
    Antochi, V. C.
    Baracchini, E.
    Cavoto, G.
    Di Marco, E.
    Marafini, M.
    Mazzitelli, G.
    Pinci, D.
    Renga, F.
    Tomassini, S.
    Voena, C.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [7] A complete simulation of a triple-GEM detector
    Bonivento, W
    Cardini, A
    Bencivenni, G
    Murtas, R
    Pinci, D
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) : 1638 - 1643
  • [8] Application of CMOS charge-sensitive preamplifier in triple-GEM detector
    LAI Yong-Fang1
    2Institute of High Energy Physics
    3Institute of Chemical Defense
    Nuclear Science and Techniques, 2006, (05) : 289 - 292
  • [9] Development of a Triple-GEM detector with strip readout and GEMINI chip for X rays and neutron imaging
    Caruggi, F.
    Celora, A.
    Cancelli, S.
    Gorini, G.
    Grosso, G.
    Guiotto, F.
    Muraro, A.
    Cippo, E. Perelli
    Petruzzo, M.
    Putignano, O.
    Tardocchi, M.
    Giarratana, L. S.
    Croci, G.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (02)
  • [10] X-ray holography with a position sensitive detector
    Lausi, A
    Kopecky, M
    Busetto, E
    Savoia, A
    ACTA PHYSICA POLONICA A, 2002, 101 (05) : 621 - 628