Estimating the octanol-water partition coefficients of NPAHs and PAHs by solid-phase microextraction and gas chromatography-ion trap detector

被引:5
|
作者
Wang, Yiru [1 ]
Wang, Yonghong
机构
[1] Xiamen Univ, Coll Chem & Chem Engn, Key Lab Analyt Sci, Minist Educ, Xiamen 361005, Peoples R China
[2] Xiamen Univ, Coll Chem & Chem Engn, Dept Chem, Xiamen 361005, Peoples R China
[3] Kodak Co Ltd, Xiamen, Peoples R China
关键词
solid-phase microextraction; NPAHs; PAHs; partition coefficient; gas chromatography-mass spectrometry;
D O I
10.1080/00032710600867663
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The solid-phase microextraction technique ( SPME) was used for the measurement of the partition coefficients of eight nitro polycyclic aromatic hydrocarbons (NPAHs) and ten polycyclic aromatic hydrocarbons (PAHs) between the polymeric coating of polydimethylsiloxane used in SPME and water (K-SW). The results demonstrate that the technique is simple, rapid, and reproducible, and thus provides a viable alternative to the conventional methods used for such measurements. There is a strong linear correlation between log K-SW and the commonly used log K-OW (octanol - water partition coefficient) for PAHs, NPAHs, PCBs, and simple aromatics. The log K-OW values for NPAHs range from 2.78 to 4.75, and exhibit a general increase in value with increasing molecular weight. NPAHs are thus noticeably less hydrophobic than their parent PAHs counterparts, for which the log K-OW values range from 3.35 to 5.20.