Effects of ignition, obstacle, and side vent locations on vented hydrogen-air explosions in an obstructed duct

被引:45
|
作者
Li, Hongwei [1 ]
Guo, Jin [2 ]
Tang, Zesi [2 ]
Li, Jialin [2 ]
Huang, Ping [2 ]
Zhang, Su [2 ]
机构
[1] Anhui Univ Sci & Technol, Sch Chem Engn, Huainan 232001, Anhui, Peoples R China
[2] Fuzhou Univ, Coll Environm & Resources, Fuzhou 350116, Fujian, Peoples R China
基金
中国国家自然科学基金;
关键词
Vented deflagration; Hydrogen; Ignition location; Side vent; Obstacle location; GAS-EXPLOSIONS; FLAME; OVERPRESSURES; DEFLAGRATION; PRESSURE; POSITION; ACCELERATION; DETONATION; MIXTURES; SIZE;
D O I
10.1016/j.ijhydene.2019.06.029
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Experiments were conducted in a 6-m-long duct with a cross section of 300 mm x 300 mm to investigate the effects of the ignition, obstacle, and side vent locations on the vented deflagration of 18 vol% hydrogen-air mixtures. Significant effects of all three parameters were found. For ignitions near the open end, explosion venting was accompanied by continuous pressure oscillations. When the ignition location was near the closed end, dominant pressure peaks appeared at the exit of the duct, which were due to the shock-wave resulting from flame acceleration induced by the obstacle. The overall maximum internal and external overpressures increased when the ignition location was moved from near the open end to the closed end of the duct but did not vary monotonically with the location of the obstacle or side vent. In the tests with different obstacle locations, the maximum internal pressure occurred near the open end when the obstacle was located at the center of the duct. Compared to the cases without a side vent, the maximum internal overpressure was effectively reduced when a side vent was introduced near the ignition point but increased when the side vent was located near the open end of the duct. (C) 2019 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:20598 / 20605
页数:8
相关论文
共 50 条
  • [1] Effect of ignition position on vented hydrogen-air explosions
    Guo, Jin
    Sun, Xuxu
    Rui, Shengchao
    Cao, Yong
    Hu, Kunlun
    Wang, Changjian
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (45) : 15780 - 15788
  • [2] Effects of equivalence ratio, thickness of rupture membrane and vent area on vented hydrogen-air deflagrations in an end-vented duct with an obstacle
    Zhang, Su
    Tang, Zesi
    Li, Jialin
    Wang, Jingui
    Zhang, Jiaqing
    Guo, Jin
    Li, Qiang
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (47) : 26100 - 26108
  • [3] Effect of ignition locations on vented explosion of premixed hydrogen-air mixtures
    Cao Y.
    Guo J.
    Hu K.
    Shao K.
    Yang F.
    Baozha Yu Chongji/Explosion and Shock Waves, 2016, 36 (06): : 847 - 852
  • [4] TRANSITION TO DETONATION IN VENTED HYDROGEN-AIR EXPLOSIONS
    DOROFEEV, SB
    BEZMELNITSIN, AV
    SIDOROV, VP
    COMBUSTION AND FLAME, 1995, 103 (03) : 243 - 246
  • [5] Effects of ignition location and vent area on the external explosion in vented hydrogen explosions
    Rui, Shengchao
    Wang, Qiao
    Wang, Changjian
    Zhang, Aifeng
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2024, 183 : 602 - 616
  • [6] Effect of vent size on vented hydrogen-air explosion
    Zhang, Sihong
    Zhang, Qi
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (37) : 17788 - 17799
  • [7] Experimental study on the effects of ignition location and vent burst pressure on vented hydrogen-air deflagrations in a cubic vessel
    Rui, Shengchao
    Wang, Changjian
    Luo, Xinjiao
    Li, Quan
    Zhang, Haoran
    FUEL, 2020, 278
  • [8] Effects of nitrogen addition on vented hydrogen-air deflagration in a vertical duct
    Guo, Jin
    Wang, Xuebiao
    Zhang, Kai
    Chen, Hao
    Du, Saifeng
    Yang, Fuqiang
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (50) : 25763 - 25770
  • [9] Modeling of vented hydrogen-air deflagrations and correlations for vent sizing
    Molkov, V
    Dobashi, R
    Suzuki, M
    Hirano, T
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 1999, 12 (02) : 147 - 156
  • [10] Vented hydrogen-air explosions at elevated static activation pressures
    Xu, Jintao
    Chen, Xiangfeng
    Jiang, Haipeng
    Gao, Wei
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2022, 168 : 474 - 486