Accurate and Precise External Calibration Enhances the Versatility of Quantitative NMR (qNMR)

被引:19
|
作者
Nishizaki, Yuzo [1 ,2 ,3 ]
Lankin, David C. [2 ,4 ]
Chen, Shao-Nong [2 ,4 ]
Pauli, Guido F. [2 ,4 ]
机构
[1] Univ Illinois, Pharmacognosy Inst PI, Coll Pharm, Chicago, IL 60612 USA
[2] Univ Illinois, Dept Pharmaceut Sci PSCI, Coll Pharm, Chicago, IL 60612 USA
[3] Natl Inst Hlth Sci NIHS, Div Food Addit, Kawasaki, Kanagawa 2109501, Japan
[4] Univ Illinois, Coll Pharm, Ctr Nat Prod Technol CENAPT, Pharmacognosy Inst PI, Chicago, IL 60612 USA
关键词
Thermal conductivity - Data acquisition - Calibration;
D O I
10.1021/acs.analchem.0c02967
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantitative H-1 nuclear magnetic resonance (qHNMR) is a highly regarded analytical methodology for purity determination as it balances metrological rigor, practicality, and versatility well. While ideal for intrinsically mass-limited samples, external calibration (EC) qHNMR is overshadowed by the prevalence of internal calibration and perceived rather than real practical limitations. To overcome this hurdle, this study applied the principle of reciprocity, certified reference materials (caffeine as analyte, dimethyl sulfone as calibrant), and a systematic evaluation of data acquisition workflows to extract key factors for the achievement of accuracy and precision in EC-qHNMR. Automatic calibration of the 90 degrees pulse width (90 PW) formed the foundation for the principle of reciprocity and used optimized nutation experiments, showing good agreement with values derived from manual high-precision measurement of 360 PW. Employing the automatic 90 PW calibration, EC-qHNMR with automatic vs manual tuning and matching (T&M) yielded the certified purity value within 1% error. The timing of T&M (before vs after shimming) turned out to be critically important: sufficient time is required to achieve full-temperature equilibrium relative to thermal gradients in the air inside the probe and the sample. Achievable accuracy across different NMR solvents varies with differences in thermal conductivity and leads to 2% or greater errors. With matching solvents, the demonstrated accuracy of similar to 1.0% underscores the feasibility of EC-qHNMR as a highly practical research tool.
引用
收藏
页码:2733 / 2741
页数:9
相关论文
共 50 条
  • [1] Standardization and Practical Application of Quantitative NMR (qNMR)
    Sugimoto, Naoki
    [J]. YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2024, 144 (04): : 353 - 357
  • [2] Precise and accurate quantitative 13C NMR with reduced experimental time
    Caytan, Elsa
    Remaud, Gerald S.
    Tenailleau, Eve
    Akoka, Serge
    [J]. TALANTA, 2007, 71 (03) : 1016 - 1021
  • [3] Absolute content determination by quantitative NMR (qNMR) spectroscopy: a curious case of aldosterone
    Singh, Neeraj
    Taibon, Judith
    Pongratz, Stephan
    Geletneky, Christian
    [J]. RSC ADVANCES, 2021, 11 (38) : 23627 - 23630
  • [4] Necessity of Reticulocyte Calibration for More Accurate and Precise Results
    Lim, Yong Kwan
    Chi, Hyun-Young
    Lee, Mi-Kyung
    Kim, Hye Ryoun
    [J]. ANNALS OF LABORATORY MEDICINE, 2018, 38 (04) : 375 - 377
  • [5] Quantitative NMR (qNMR) for pharmaceutical analysis: The pioneering work of George Hanna at the US FDA
    Jaki, Birgit U.
    Bzhelyansky, Anton
    Pauli, Guido F.
    [J]. MAGNETIC RESONANCE IN CHEMISTRY, 2021, 59 (01) : 7 - 15
  • [6] Absolute Purity Determination of a Hygroscopic Substance, Indocyanine Green, Using Quantitative NMR (qNMR)
    Uchiyama, Nahoko
    Hosoe, Junko
    Sugimoto, Naoki
    Ishizuki, Kyoko
    Koide, Tatsuo
    Murabayashi, Mika
    Miyashita, Naoto
    Kobayashi, Kengo
    Fujimine, Yoshinori
    Yokose, Toshiyuki
    Ofuji, Katsuya
    Shimizu, Hitoshi
    Hasebe, Takashi
    Asai, Yumi
    Ena, Eri
    Kikuchi, Junko
    Kiyota, Kohei
    Fujita, Kazuhiro
    Makino, Yoshinobu
    Yasobu, Naoko
    Yamada, Yuko
    Iwamoto, Yoshiaki
    Miura, Toru
    Mizui, Koji
    Asakura, Katsuo
    Suematsu, Takako
    Kohama, Ai
    Goda, Yukihiro
    [J]. CHEMICAL & PHARMACEUTICAL BULLETIN, 2021, 69 (01) : 118 - 123
  • [7] Accurate quantification resulting from precise beam monitoring and calibration
    Wallianos, A
    Arndt, P
    Maetz, M
    Schneider, T
    Traxel, K
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 130 (1-4): : 144 - 148
  • [8] Accurate and precise wavelength calibration for wide bandwidth array spectrometers
    Martinsen, Paul
    Jordan, Bob
    McGlone, Andrew
    Gaastra, Paul
    Laurie, Tom
    [J]. APPLIED SPECTROSCOPY, 2008, 62 (09) : 1008 - 1012
  • [9] Monitoring daily routine performance in quantitative NMR (qNMR) spectroscopy: Is the system suitability test necessary?
    Monakhova, Yulia B.
    Diehl, Bernd W. K.
    [J]. MAGNETIC RESONANCE IN CHEMISTRY, 2019, 57 (2-3) : 110 - 117
  • [10] Enzyme kinetics by real-time quantitative NMR (qNMR) spectroscopy with progress curve analysis
    Vang, Justin Y.
    Breceda Jr, Candido
    Her, Cheenou
    Krishnan, V. V.
    [J]. ANALYTICAL BIOCHEMISTRY, 2022, 658