A novel, label-free immunosensor for the detection of α-fetoprotein using functionalised gold nanoparticles

被引:42
|
作者
Liang, Wenbin [1 ,2 ]
Yi, Weijing [2 ]
Li, Shuhui [2 ]
Yuan, Ruo [1 ]
Chen, An [2 ]
Chen, Sha [2 ]
Xiang, Guiming [3 ]
Hu, Chuanmin [2 ]
机构
[1] Southwest Univ, Coll Chem & Chem Engn, Chongqing Key Lab Analyt Chem, Chongqing 400715, Peoples R China
[2] Third Mil Med Univ, Lab Sci, Dept Clin Biochem, Chongqing 400038, Peoples R China
[3] Third Mil Med Univ, Xinqiao Hosp, Dept Lab Med, Chongqing 40037, Peoples R China
基金
中国国家自然科学基金;
关键词
Sulfhyrdryl viologen; Functional gold nanoparticle; alpha-1-fetoprotein; Immunosensor; DISPOSABLE AMPEROMETRIC IMMUNOSENSOR; ANTIGEN-ANTIBODY INTERACTIONS; SEPARATION-FREE IMMUNOASSAY; HEPATOCELLULAR-CARCINOMA; IMPEDANCE SPECTROSCOPY; ELECTRODE; FILMS; ALPHA-1-FETOPROTEIN; THIONINE; SERUM;
D O I
10.1016/j.clinbiochem.2009.07.009
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background and objectives: Novel immunoassay methods based on electrochemical sensors have been developed, but most of these immunosensors are unsuitable for clinical detection because their preparation requires complicated chemical procedures and because their detection sensitivity is restricted. In order to develop a highly sensitive, label-free amperometric sensor for immunoassays, we synthesised novel, functionalised gold nanoparticles (SV-GNP) by covalently capping the surface of gold nanoparticles (GNP) with 1,1'-bis-(2-mercapto)-4,4'-bipyridinium dibromide, a kind of sulfhyrdryl viologen (SV). Design and methods: We fabricated an immunosensor in a multi-step fashion, by first coating the SV-GNP onto a glassy carbon electrode surface; the resulting electrode core could then adsorb a suitable antibody in a second step to afford the desired immunosensor. alpha-fetoprotein (AFP) was used as a model analyte in this work. Results: The anti-AFP/SV-GNP-modified electrode was sensitive to AFP with a linear relationship between 1.25 and 200 ng/mL and a correlation coefficient of 0.9983; the detection limit at a signal to noise ratio of 3 was 0.23 ng/mL under optimal conditions. In addition, the proposed immunosensor exhibited good sensitivity, selectivity, stability and long-term maintenance of bioactivity. Conclusion: The described immunosensor preparation and immunoassay methods offer promise for label-free, simple, and cost-effective analysis of biological samples. (C) 2009 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1524 / 1530
页数:7
相关论文
共 50 条
  • [1] A novel label-free voltammetric immunosensor for the detection of α-fetoprotein using functional titanium dioxide nanoparticles
    Liang, Wen-Bin
    Yuan, Ruo
    Chai, Ya-Qin
    Li, Yan
    Zhuo, Ying
    ELECTROCHIMICA ACTA, 2008, 53 (05) : 2302 - 2308
  • [2] A label-free electrochemical immunosensor based on gold nanoparticles for detection of paraoxon
    Hu, SQ
    Xie, JW
    Xu, QH
    Rong, KT
    Shen, GL
    Yu, RQ
    TALANTA, 2003, 61 (06) : 769 - 777
  • [3] A label-free electrochemical immunosensor based on gold nanoparticles for direct detection of atrazine
    Liu, Xia
    Li, Wen-Jin
    Li, Lei
    Yang, Yang
    Mao, Lu-Gang
    Peng, Zhang
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 191 : 408 - 414
  • [4] A sensitive label-free immunosensor for detection α-Fetoprotein in whole blood based on anticoagulating magnetic nanoparticles
    Xu, Tingting
    Chi, Bo
    Wu, Fan
    Ma, Shangshang
    Zhan, Shuyue
    Yi, Meihui
    Xu, Hong
    Mao, Chun
    BIOSENSORS & BIOELECTRONICS, 2017, 95 : 87 - 93
  • [5] Label-free immunosensor based on hyperbranched polyester for specific detection of α-fetoprotein
    Niu, Yanlian
    Yang, Tian
    Ma, Shangshang
    Peng, Fang
    Yi, Meihui
    Wan, Mimi
    Mao, Chun
    Shen, Jian
    BIOSENSORS & BIOELECTRONICS, 2017, 92 : 1 - 7
  • [6] Label-Free Immunosensor Based on Liquid Crystal and Gold Nanoparticles for Cardiac Troponin I Detection
    Zapp, Eduardo
    Brondani, Daniela
    Silva, Tania Regina
    Girotto, Edivandro
    Gallardo, Hugo
    Vieira, Iolanda Cruz
    BIOSENSORS-BASEL, 2022, 12 (12):
  • [7] Label-free detection of bisphenol A using a potentiometric immunosensor
    Piao, Ming-Hua
    Noh, Hui-Bog
    Rahman, Md Aminur
    Won, Mi-Sook
    Shim, Yoon-Bo
    ELECTROANALYSIS, 2008, 20 (01) : 30 - 37
  • [8] Development of a label-free photoelectrochemical immunosensor for novel astrovirus detection
    Shen, Quan
    Qian, Lingling
    Chen, Yun
    Bao, Yingying
    Wang, Jiangqiang
    Wang, Xiaochun
    Liu, Yuwei
    Yang, Shixing
    Ji, Likai
    Shan, Tongling
    Li, Henan
    Zhang, Wen
    MICROCHIMICA ACTA, 2024, 191 (07)
  • [9] A label-free electrochemical immunosensor based on gold nanoparticles and graphene oxide for the detection of tumor marker calcitonin
    Alarfaj, Nawal A.
    El-Tohamy, Maha F.
    NEW JOURNAL OF CHEMISTRY, 2017, 41 (19) : 11029 - 11035
  • [10] A novel label-free impedimetric immunosensor for detection of semicarbazide residue based on gold nanoparticles-functional chitosan composite membrane
    Jin, Wen-Jie
    Yang, Gong-Jun
    Shao, Hong-Xia
    Qin, Ai-Jian
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 271 - 279