DEVELOPMENT OF FEMALE ATOM-MIRD HYBRID VOXEL MODEL FOR MONTE CARLO DOSE CALCULATIONS

被引:0
|
作者
Cho, Sungkoo [1 ]
Yang, Il Hyuk [1 ]
Jeong, Jong Hwi [1 ]
Kim, Chan Hyeong [1 ]
机构
[1] Hanyang Univ, Dept Nucl Engn, Seoul 133791, South Korea
关键词
hybrid voxel model; female ATOM phantom; Monte Carlo; ANTHROPOMORPHIC PHANTOMS; CT;
D O I
10.13182/NT09-A9127
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A hybrid-type female computational model was constructed by combining the tomographic voxel model of the A TOM adult female physical phantom with the mathematical organ models of the MIRD5 stylized phantom. The constructed model has 13 internal organs: 5 organs from the ATOM phantom and the other 8 organs from the MIRD5 phantom. The model was employed in Monte Carlo dose calculations with MCNPX to calculate organ doses, and the calculated values were compared with the values of Regina for reference external irradiation conditions.
引用
收藏
页码:209 / 212
页数:4
相关论文
共 50 条
  • [1] ATOM-MIRD Hybrid Voxel Model for Monte Carlo Calculations of Organ Doses: A Complement to a Physical Phantom
    Cho, Sungkoo
    Choi, Sang Hyoun
    Yi, Chul-Young
    Kim, Chan Hyeong
    [J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 306 - 308
  • [2] Effect of voxel size on Monte Carlo dose calculations
    Qin, L
    Yang, J
    Li, J
    Chen, L
    Price, R
    Ma, C
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1883 - 1883
  • [3] Development of a Monte Carlo model for dose calculations in IMRT
    Aaronson, R
    DeMarco, J
    Chetty, I
    Solberg, T
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1330 - 1330
  • [4] Investigation of Nonuniform Dose Voxel Geometry in Monte Carlo Calculations
    Yuan, Jiankui
    Chen, Quan
    Brindle, James
    Zheng, Yiran
    Lo, Simon
    Sohn, Jason
    Wessels, Barry
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (04) : 419 - 427
  • [5] Monte Carlo tumor dosimetry calculations for BNCT voxel model
    Laboratory of Computational Physics, Institute of Applied Physics and Computational Mathematics, Beijing 100088, China
    [J]. Qinghua Daxue Xuebao, 2007, SUPPL. 1 (910-913):
  • [6] Effect of voxel size on Monte Carlo dose calculations for radiotherapy treatment planning
    Mora, G
    Pawlicki, T
    Maio, A
    Ma, CM
    [J]. ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 549 - 554
  • [7] Voxel-based mouse model for internal dose calculations using Monte Carlo simulations (MCNP)
    Bitar, A.
    Lisbona, A.
    Thedrez, P.
    Maurel, C. Sai
    Le Forestier, D.
    Bardies, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S110 - S110
  • [8] The development and application of the Visible Chinese Human model for Monte Carlo dose calculations
    Zhang, Guozhi
    Luo, Qingming
    Zeng, Shaoqun
    Liu, Qian
    [J]. HEALTH PHYSICS, 2008, 94 (02): : 118 - 125
  • [9] Absorbed dose of 18F-FDG for female patients: Monte Carlo versus MIRD method
    Ezzati, Ahad Ollah
    Mohajeri, Farzane
    [J]. EUROPEAN PHYSICAL JOURNAL PLUS, 2023, 138 (01):
  • [10] Absorbed dose of 18F-FDG for female patients: Monte Carlo versus MIRD method
    Ahad Ollah Ezzati
    Farzane Mohajeri
    [J]. The European Physical Journal Plus, 138