FULL-SCALE SIMULATIONS OF MAGNETORHEOLOGICAL DAMPER FOR IMPLEMENTATION OF SEMI-ACTIVELY STRUCTURAL CONTROL

被引:9
|
作者
Peng, Y. B. [1 ,2 ]
Zhang, Z. K. [3 ]
Yang, J. G. [3 ]
Wang, L. H. [4 ]
机构
[1] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai, Peoples R China
[2] Tongji Univ, Shanghai Inst Disaster Prevent & Relief, Shanghai, Peoples R China
[3] Tongji Univ, Coll Civil Engn, Shanghai, Peoples R China
[4] Tongji Univ, Sch Aerosp Engn & Appl Mech, Shanghai, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
MR damper; Finite element simulation; Hysteretic behaviors; Computational fluid dynamics; Herschel-Bulkley model; Semi-active control; DESIGN; FLUID; MODEL; CFD;
D O I
10.1017/jmech.2018.26
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Full-scale simulations of a (Magnetorheological) MR damper are carried out for revealing its hysteretic behaviors associated with implementation of semi-active control using the routine of computational fluid dynamics. By virtue of the structural symmetry of the MR damper, a two-dimensional configuration for finite element simulation is built up. Herschel-Bulkley model is employed to represent the property of the MR fluid, of which the control parameters and their relevances to the input current are addressed. Typical cases involving sinusoidal and irregular displacements, steady and transient currents loaded upon the MR damper are investigated. Numerical investigations reveal that the damper force has a positive correlation with input current, excitation amplitude and excitation frequency. The full-scale simulation is proved to exhibit a sound accuracy through the validation of experimental data. It provides a logical manner revealing the true performance of MR dampers under desirable operating modes in practice, and can be readily integrated with the gain design of the associated semi-actively controlled structure. This progress bypasses the technical challenge inherent in the traditional tests with low-frequency cyclic loadings due to the limitation of experimental setup. Besides, comparative study between two-dimensional and three-dimensional configuration simulations of the MR damper shows that former has a better applicability, which can be carried out on a low-cost platform.
引用
收藏
页码:549 / 562
页数:14
相关论文
共 50 条
  • [1] On a semi-actively controlled dynamic vibration damper
    Okada, Yohji
    Nagai, Bunshu
    Matsuda, Kenichi
    Nippon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, 1988, 54 (503): : 1427 - 1432
  • [2] Sprung mass positioning by semi-actively controlled damper
    Jenis, Filip
    Mazurek, Ivan
    SCIENTIFIC-TECHNICAL CONFERENCE: E-MOBILITY, SUSTAINABLE MATERIALS AND TECHNOLOGIES (MATBUD'2020), 2020, 322
  • [3] Real-time Hybrid Test on a Semi-actively Controlled Building Structure Equipped with Full-scale MR Dampers
    Park, Eunchurn
    Min, Kyung-Won
    Lee, Sung-Kyung
    Lee, Sang-Hyun
    Lee, Heon-Jae
    Moon, Seok-Jun
    Jung, Hyung-Jo
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2010, 21 (18) : 1831 - 1850
  • [4] Development of a full-scale magnetorheological damper model for open-loop cable vibration control
    Zhang, Ru
    Ni, Yi-Qing
    Duan, Yuanfeng
    Ko, Jan-Ming
    SMART STRUCTURES AND SYSTEMS, 2019, 23 (06) : 553 - 564
  • [5] Dynamic loading test and simulation analysis of full-scale semi-active hydraulic damper for structural control
    Niwa, Naoki
    Kobori, Takuji
    Takahashi, Motoichi
    Midorikawa, Hiroshi
    Kurata, Narito
    Mizuno, Takayuki
    2000, John Wiley & Sons Ltd, Chichester (29)
  • [6] Dynamic loading test and simulation analysis of full-scale semi-active hydraulic damper for structural control
    Niwa, N
    Kobori, T
    Takahashi, M
    Midorikawa, H
    Kurata, N
    Mizuno, T
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2000, 29 (06): : 789 - 812
  • [7] Real-Time Hybrid Testing of a Semi-Actively Controlled Structure with an MR Damper
    Carrion, Juan E.
    Spencer, B. F., Jr.
    Phillips, Brian M.
    2009 AMERICAN CONTROL CONFERENCE, VOLS 1-9, 2009, : 5234 - +
  • [8] Response control of full-scale irregular buildings using magnetorheological dampers
    Yoshida, O
    Dyke, SJ
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2005, 131 (05): : 734 - 742
  • [9] Modeling of an actively braced full-scale building considering control-structure interaction
    Wu, JC
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2000, 29 (09): : 1325 - 1342
  • [10] Modeling of an actively braced full-scale building considering control-structure interaction
    Wu, Jong-Cheng
    Earthquake Engineering and Structural Dynamics, 2000, 29 (09) : 1325 - 1342