Reagentless Amperometric Immunosensor Based on Human Immunodefficiency Virus Diagnosis Marker Glycoprotein 160 Antibody Coated Gold-magnetic Particles Modified Electrode

被引:4
|
作者
Gan Ning [1 ]
Wang Lu-Yan [1 ]
Li Tian-Hua [1 ]
Zheng Lei [2 ]
Wang Feng [1 ]
机构
[1] Ninbo Univ, State Key Lab, Ningbo 315211, Zhejiang, Peoples R China
[2] Nanfang Med Univ, Dept Lab, Guangzhou 410003, Guangdong, Peoples R China
关键词
Dimethyl fumarate bipyridine copper(II) complex; nano Au/Fe3O4; magnetic particles; chitosan; human immunodefficiency virus; diagnosis marker glycoprotein; reagentless amperometric immunosensor; FILM; ELECTROCATALYSIS; NANOPARTICLES; COPPER(II); NANOWIRES; MATRIX;
D O I
10.1016/S1872-2040(08)60121-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel amperometric immunosensor for human immunodefficiency virus (HIV) glycoprotein 160 (gp160) based on nanoAu/Fe3O4/Chitosan(chit) composite film as immobilization matrix was investigated. Firstly, the complex [Cu(bpy)(2) (H2O)](2) (C6H8O4)(2) (ClO4)(4), (CuL) was prepared and adsorbed on the surface of glassy carbon electrode(GCE), then nanoAu/Fe3O4/Chitosan composite film was modified on the surface of GCE|CuL and HIV gp160 antibody was furthermore immobilized on the surface to form one gp160 immunosensor(GCE|CuL/nanoAu/Fe3O4/Chit/anti gp160). CuL can be employed as an electron transfer mediator for catalytic activity detection of H2O2. After the immunosensor was incubated with HIV gp160 solution at 37 degrees C for 30 min, the electron transfer access of CuL to H2O2 Is partly inhibited, which led to a linear decrease of the catalytic efficiency to H2O2 by the oxidation of immobilized CuL by H2O2 at - 300 mV in pH 7.0 PBS. Under the optimal conditions, the linear range of gp160 by the immunosensor is 1-400 mu g/L and the detection limit is 0.5 mu g/L at 3 times noise. The immunosensor shows more sensitivity and accuracy than that only modified by gp160 antibody coated nano Au/chitosan film. This method simplifies the detection system without adding electron transfer media to solution and shortens the analytical time with one-step Immunoassay, thus would be valuable for clinical immunoassay for HIV gp160 in AIDs patients' serums
引用
收藏
页码:1125 / 1130
页数:6
相关论文
共 18 条
  • [1] Dendritic cell-lysosomal-associated membrane protein (LAMP) and LAMP-1-HIV-1 Gag chimeras have distinct cellular trafficking pathways and prime T and B cell responses to a diverse repertoire of epitopes
    Arruda, Luciana B.
    Sim, Del
    Chikhlikar, Priya R.
    Maciel, Milton, Jr.
    Akasaki, Kenji
    August, J. Thomas
    Marques, Ernesto T. A.
    [J]. JOURNAL OF IMMUNOLOGY, 2006, 177 (04): : 2265 - 2275
  • [2] Electrocatalysis for the reduction of O-2 and H2O2 based on complex of copper(II) with the tris(3-aminopropyl)amine and imidazole ligands
    Cai, CX
    Xue, KH
    Xu, XY
    Luo, QH
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 1997, 27 (07) : 793 - 798
  • [3] A strategy for sensitivity and specificity enhancements in prostate specific antigen-α1-antichymotrypsin detection based on surface plasmon resonance
    Cao, C
    Kim, JP
    Kim, BW
    Chae, H
    Yoon, HC
    Yang, SS
    Sim, SJ
    [J]. BIOSENSORS & BIOELECTRONICS, 2006, 21 (11): : 2106 - 2113
  • [4] A CARRAGEENAN HYDROGEL STABILIZED COLLOIDAL GOLD MULTIENZYME BIOSENSOR ELECTRODE UTILIZING IMMOBILIZED HORSERADISH-PEROXIDASE AND CHOLESTEROL OXIDASE CHOLESTEROL ESTERASE TO DETECT CHOLESTEROL IN SERUM AND WHOLE-BLOOD
    CRUBLISS, AL
    STONEHUERNER, JG
    HENKENS, RW
    ZHAO, J
    ODALY, JP
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (06): : 331 - 337
  • [5] CUI YL, 2006, CHINA SCI B, V36, P159
  • [6] Novel amperometric immunosensor for rapid separation-free immunoassay of carcinoembryonic antigen
    Dai, Z
    Yan, F
    Hua, Y
    Hu, XY
    Ju, HX
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2004, 287 (1-2) : 13 - 20
  • [7] A simple method to fabricate a chitosan-gold nanoparticles film and its application in glucose biosensor
    Du, Ying
    Luo, Xi-Liang
    Xu, Jing-Juan
    Chen, Hong-Yuan
    [J]. BIOELECTROCHEMISTRY, 2007, 70 (02) : 342 - 347
  • [8] Gan N, 2007, CHINESE J ANAL CHEM, V35, P1553
  • [9] A sensitive amperometric immunosensor for carcinoembryonic antigen detection with porous nanogold film and nano-Au/chitosan composite as immobilization matrix
    He, Xiulan
    Yuan, Ruo
    Chai, Yaqin
    Shi, Yintao
    [J]. JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2008, 70 (06): : 823 - 829
  • [10] Complementary detection of prostate-specific antigen using ln2O3 nanowires and carbon nanotubes
    Li, C
    Curreli, M
    Lin, H
    Lei, B
    Ishikawa, FN
    Datar, R
    Cote, RJ
    Thompson, ME
    Zhou, CW
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (36) : 12484 - 12485