Thermo-time domain reflectometry to evaluate unsaturated soils contaminated with nonaqueous phase liquids

被引:3
|
作者
Ju, Zhaoqiang [1 ]
Sun, Hongyong [1 ]
Liu, Xiaojing [1 ]
机构
[1] Chinese Acad Sci, Ctr Agr Resources Res, Key Lab Agr Water Resources, Inst Genet & Dev Biol, 286 Huaizhong Rd, Shijiazhuang 050021, Hebei, Peoples R China
基金
中国国家自然科学基金;
关键词
WATER CONTENT; SANDY SOILS; CONDUCTIVITY; HEAT; PROBE; TDR;
D O I
10.1002/vzj2.20016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Soil and groundwater contamination by nonaqueous phase liquids (NAPLs) has become a serious environmental issue. This study applied the thermo-time domain reflectometry (TTDR) technique to determine the effects of NAPL contamination on the thermal and electromagnetic properties of unsaturated soils. Furthermore, the applicability of TTDR to determine the NAPL content was evaluated, and a new calibration equation was established to estimate the NAPL saturation level in unsaturated soils. Multiple unsaturated sand and silt loam samples at a constant water content were mixed with various amounts of motor and sunflower seed oils. The TTDR probes were then applied to simultaneously measure the dielectric constant, electrical conductivity, thermal conductivity, and heat capacity. An independent experiment was conducted to compare the NAPL content estimated using the new calibration equation and the known content. The results show that the NAPL content had no effect on the dielectric constant, and the soil dielectric constant maintained a steady value at the same water content, which ranged from 5 to 20 with increasing water content. At a constant water content, the soil electrical conductivity slightly decreased as the NAPL content increased. The soil thermal conductivity generally increased with the addition of NAPLs. There was a linear correlation between the total liquid content in the soil and the volumetric heat capacity. A new calibration equation was established to determine the NAPL saturation in soils from the relationship between the soil saturation, volumetric heat capacity, and water content as measured by time domain reflectometry. Independent validation indicated that the calibration equation was able to provide accurate NAPL saturation data in the laboratory, with a RMSE of 0.042.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] A partial cylindrical thermo-time domain reflectometry sensor
    Olmanson, Ole K.
    Ochsner, Tyson E.
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2008, 72 (03) : 571 - 577
  • [2] Development of Thermo-Time Domain Reflectometry for Vadose Zone Measurements
    Ren, Tusheng
    Ochsner, Tyson E.
    Horton, Robert
    VADOSE ZONE JOURNAL, 2003, 2 (04): : 544 - 551
  • [3] Advances in thermo-time domain reflectometry technique: Measuring ice content in partially frozen soils
    Tian, Zhengchao
    Kojima, Yuki
    Heitman, Joshua L.
    Horton, Robert
    Ren, Tusheng
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2020, 84 (05) : 1519 - 1526
  • [4] An improved thermo-time domain reflectometry method for determination of ice contents in partially frozen soils
    Tian, Zhengchao
    Ren, Tusheng
    Kojima, Yuki
    Lu, Yili
    Horton, Robert
    Heitman, Joshua L.
    JOURNAL OF HYDROLOGY, 2017, 555 : 786 - 796
  • [5] Determination of soil bulk density with thermo-time domain reflectometry sensors
    Liu, Xiaona
    Ren, Tusheng
    Horton, Robert
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2008, 72 (04) : 1000 - 1005
  • [6] Measuring soil freezing characteristic curve with thermo-time domain reflectometry
    Tian, Zhengchao
    Wang, Li
    Ren, Tusheng
    EUROPEAN JOURNAL OF SOIL SCIENCE, 2023, 74 (01)
  • [7] Root influences on soil bulk density measurements with thermo-time domain reflectometry
    Fu, Yongwei
    Lu, Yili
    Heitman, Joshua
    Ren, Tusheng
    GEODERMA, 2021, 403
  • [8] Comparing heat-pulse and time domain reflectometry soil water contents from thermo-time domain reflectometry probes
    Ren, TS
    Ju, ZQ
    Gong, YS
    Horton, R
    VADOSE ZONE JOURNAL, 2005, 4 (04) : 1080 - 1086
  • [9] Application of a thermo-time domain reflectometry probe in sand-kaolin clay mixtures
    Zhang, Nan
    Yu, Xinbao
    Pradhan, Asheesh
    ENGINEERING GEOLOGY, 2017, 216 : 98 - 107
  • [10] Determining Soil Ice Contents during Freezing and Thawing with Thermo-Time Domain Reflectometry
    Tian, Zhengchao
    Heitman, Joshua
    Horton, Robert
    Ren, Tusheng
    VADOSE ZONE JOURNAL, 2015, 14 (08):