Experience with 15-500 kV Instrument Transformers and Bushings

被引:2
|
作者
McDermid, W. [1 ]
机构
[1] Manitoba Hydro, Winnipeg, MB R3T 1Y6, Canada
关键词
D O I
10.1109/EIC.2009.5166343
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Instrument transformers are used in metering and protective relaying applications for which accuracy and transient performance are important functional requirements. Some magnetic voltage transformers are also used to discharge capacitor banks or other devices that can store a trapped charge. High voltage bushings are associated with oil filled power transformers and reactors. The reliability of instrument transformers and bushings is often determined by the insulation system, both initially and in the long term. This paper reports the more significant failures and troubles that have been experienced by one utility for instrument transformers and bushings rated 15-500 kV. Corrective measures have included modifications to the design and application as well as transport practices.
引用
收藏
页码:192 / 195
页数:4
相关论文
共 50 条
  • [1] PRODUCTION OF RE-186 WITH 15-500 MEV PROTONS
    RUTH, TJ
    GARDNER, S
    DAURIA, JM
    VINCENT, JS
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1989, 197 : 100 - NUCL
  • [2] Experience with Non Ceramic Bushings and Current Transformers in Substations
    Ramirez, Isaias
    Garcia, Rodolfo V.
    [J]. 2010 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTIC PHENOMENA, 2010,
  • [3] Experience with 550 kV Current Transformers
    McDermid, W.
    Black, T.
    [J]. 2015 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2015, : 600 - 602
  • [4] High Efficiency 15-500 MHz Wideband Cascade GaN HEMT MMIC Amplifiers
    Sardin, David
    Popovic, Zoya
    [J]. 2014 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2014,
  • [5] Electric Stress Grading on Bushings of Combined Instrument Transformers Using High Permittivity Polymeric Composites
    Paredes-Olguin, M.
    Gomez-Yanez, C.
    Espino-Cortes, F. P.
    Ramirez, E.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (06) : 2335 - 2342
  • [6] TEST SETUP FOR 110-KV TO 500-KV VOLTAGE TRANSFORMERS
    KOPSHIN, VV
    BRZHEZITSKII, VA
    KILEVOI, VK
    IERUSALIMOV, ME
    KIKALO, VN
    DOLZHENKO, AA
    KRIVOKHVOST, AP
    NAIDOVSKII, AV
    CHERKOVSKII, SA
    [J]. MEASUREMENT TECHNIQUES USSR, 1989, 32 (02): : 156 - 158
  • [7] Electric Stress Grading on Bushings of Combined Instrument Transformers Using High Permittivity Polymeric Composites
    Paredes-Olguin, M.
    Gomez-Yanez, C.
    Espino-Cortes, F. P.
    Ramirez, E.
    [J]. 2013 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2013, : 299 - 303
  • [8] PARTIAL DISCHARGE TESTS AND NOISE SUPPRESSION OF 500 KV TRANSFORMERS
    OKAMATO, H
    HORII, K
    TOMIYAMA, J
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1973, PA92 (06): : 1807 - 1807
  • [9] On-Site Measurements of Partial Discharges Through Tap of the Bushings - Brazilian Experience in Power Transformers
    Amorim, H. P., Jr.
    Carvalho, A. T. D.
    Rodrigues, T. B.
    Borges, J. B. S.
    Cunha, C. F. F. de C.
    [J]. PROCEEDINGS OF THE 2013 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS (ICSD 2013), VOLS 1 AND 2, 2013, : 1020 - 1023