The effect of aspect ratio in counter-current gas-liquid bubble columns: Experimental results and gas holdup correlations

被引:56
|
作者
Besagni, Giorgio [1 ]
Di Pasquali, Alessandro [1 ]
Gallazzini, Lorenzo [1 ]
Gottardi, Elia [1 ]
Colombo, Luigi Pietro Maria [1 ]
Inzoli, Fabio [1 ]
机构
[1] Politecn Milan, Dept Energy, Via Lambruschini 4a, I-20156 Milan, Italy
关键词
Bubble column; Gas holdup; Flow regime transitions; Counter-current mode; Electrolyte; Gas holdup correlation; FLOW REGIME TRANSITION; MASS-TRANSFER COEFFICIENT; AQUEOUS-SOLUTIONS; SCALE-UP; HYDRODYNAMICS HOLDUP; SIZE DISTRIBUTIONS; ALCOHOL ADDITION; 2-PHASE FLOW; COALESCENCE; ELECTROLYTES;
D O I
10.1016/j.ijmultiphaseflow.2017.04.015
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
It is generally admitted that the gas holdup is independent of the column dimensions and gas sparger design if three criteria are satisfied: the diameter of the bubble column is larger than 0.15 m, gas sparger openings are larger than 1-2 mm and the aspect ratio is larger than 5. This paper contributes to the existing discussion; in particular, the effect of the aspect ratio (within the range 1-15) in a counter-current gas-liquid bubble column has been experimentally studied and a new gas holdup correlation to estimate the influence of aspect ratio, operation mode and working fluid on the gas holdup has been proposed. The bubble column, equipped with a spider gas sparger, is 5.3 m in height, has an inner diameter of 0.24 m; gas superficial velocities in the range of 0.004-0.23 m/s have been considered, and, for the runs with water moving counter-currently to the gas phase, the liquid has been recirculated at a superficial velocity of -0.0846 m/s. Filtered air has been used as the gaseous phase in all the experiments, while the liquid phase has included tap water and different aqueous solutions of sodium chloride as electrolyte. Gas holdup measurements have been used to investigate the flow regime transitions and the global bubble column hydrodynamics. The counter-current mode has turned out to increase the gas holdup and destabilize the homogeneous flow regime; the presence of electrolytes has resulted in increasing the gas holdup and stabilizing the homogeneous flow regime; the aspect ratio, up to a critical value, has turned out to decrease the gas holdup and destabilize the homogeneous flow regime. The critical value of the aspect ratio ranged between 5 and 10, depending on the bubble column operation (i.e., batch or counter-current modes) and liquid phase properties. Since no correlation has been found in the literature that can correctly predict the gas holdup under the investigated conditions, a new scheme of gas holdup correlation has been proposed. Starting from considerations concerning the flow regime transition, corrective parameters are included in the gas holdup correlation to account for the effect of the changes introduced by the aspect ratio, operation mode and working fluid. The proposed correlation has been found to predict fairly well the present experimental data as well as previously published gas holdup data. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:53 / 78
页数:26
相关论文
共 50 条
  • [1] The effect of electrolyte concentration on counter-current gas-liquid bubble column fluid dynamics: Gas holdup, flow regime transition and bubble size distributions
    Besagni, Giorgio
    Inzoli, Fabio
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 2017, 118 : 170 - 193
  • [2] The effect of gas-liquid counter-current operation on gas hold-up in bubble columns using electrical resistance tomography
    Jin, Haibo
    Yang, Suohe
    He, Guangxiang
    Wang, Mi
    Williams, R. A.
    [J]. JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2010, 85 (09) : 1278 - 1283
  • [3] Experiment and Simulation Study on the Effect of Internals in Gas-Liquid Bubble Columns with a Low Aspect Ratio
    Hua, Ji
    Zhang, Xi-bao
    Li, Hu
    Luo, Zheng-Hong
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2024, 63 (10) : 4595 - 4604
  • [4] SIMULATION OF COUNTER-CURRENT GAS-LIQUID CHURN FLOW
    Tekavcic, Matej
    Koncar, Bostjan
    Kljenak, Ivo
    [J]. PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2013, VOL 2, 2014,
  • [5] Gas-liquid hydrodynamics in counter-current columns with KATAPAK®-S and BX structured packing
    Dima, Romulus
    Soare, Gheorghe
    Bozga, Grigore
    Plesu, Valentin
    [J]. REVUE ROUMAINE DE CHIMIE, 2006, 51 (03) : 219 - 226
  • [6] Effect of Gas Density on Gas Holdup in Bubble Columns
    Hecht, Kristin
    Bey, Oliver
    Ettmueller, Juergen
    Graefen, Patrick
    Friehmelt, Rainer
    Nilles, Michael
    [J]. CHEMIE INGENIEUR TECHNIK, 2015, 87 (06) : 762 - 772
  • [7] Effect of kinds of gas on gas holdup in bubble columns
    Yamashita, Fukuji
    Fukaura, Tatsuma
    [J]. ICHEAP-9: 9TH INTERNATIONAL CONFERENCE ON CHEMICAL AND PROCESS ENGINEERING, PTS 1-3, 2009, 17 : 471 - 476
  • [8] Nonlinear waves in counter-current gas-liquid film flow
    Tseluiko, D.
    Kalliadasis, S.
    [J]. JOURNAL OF FLUID MECHANICS, 2011, 673 : 19 - 59
  • [9] Hydrodesulphurization of gasoils: Advantages of counter-current gas-liquid contacting
    Ojeda, JA
    Ramirez, J
    Krishna, R
    [J]. EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING - 12, 2002, 10 : 277 - 282
  • [10] EFFECT OF GAS-LIQUID FLOW MODE AND COLUMN DIAMETER ON GAS HOLDUP AND GAS-LIQUID INTERFACIAL AREA IN BUBBLE COLUMN
    BANDO, Y
    KURAISHI, M
    NISHIMURA, M
    ANDO, S
    HATTORI, M
    AOYAMA, K
    [J]. KAGAKU KOGAKU RONBUNSHU, 1988, 14 (02) : 182 - 188