Impact of radial artery cannulation for coronary angiography and angioplasty on radial artery function

被引:68
|
作者
Burstein, Jason M.
Gidrewicz, Dominica
Hutchison, Stuart J.
Holmes, Kate
Jolly, Sanjit
Cantor, Warren J.
机构
[1] Univ Toronto, Toronto, ON, Canada
[2] St Michaels Hosp, Div Cardiol, Toronto, ON M5B 1W8, Canada
[3] Southlake Reg Hlth Ctr, Div Cardiol, Newmarket, ON, Canada
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2007年 / 99卷 / 04期
关键词
D O I
10.1016/j.amjcard.2006.08.055
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The radial artery is commonly used as a conduit in coronary artery bypass grafting. No data exist on the effects of radial sheath insertion on radial artery function. Because many patients considered for coronary artery bypass grafting have had previous radial procedures, it is important to understand any effects radial sheath insertion may have on radial artery function. Twenty-two patients who underwent elective coronary angiography or angioplasty with a 6Fr sheath through the right radial artery were studied. Radial artery function was assessed using ultrasound to measure flow-mediated dilation (FMD). Reactive hyperemia was produced by 5-minute cuff inflation on the arm to suprasystolic pressures. Radial artery diameter was measured at rest and I minute after cuff deflation. FMD was expressed as percent change in radial diameter compared with at rest. In all cases, the left radial artery was studied as a control. Patients were studied before sheath insertion, immediately after sheath insertion, and 6 weeks after sheath insertion. The FMD of the cannulated arm was 13.2% before sheath insertion versus 3.6% immediately after sheath insertion (p < 0.01) and 0.2% (p < 0.01) 9 weeks after sheath insertion. In contrast, there were no significant changes in the noncannulated arm at either time point. In conclusion, radial artery sheath insertion for coronary angiography or angioplasty results in immediate and persistent blunting of FMD, suggesting severe vasomotor dysfunction. Radial artery sheath insertion has important effects on radial artery function that must be considered when selecting radial conduits for coronary artery bypass grafting. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:457 / 459
页数:3
相关论文
共 50 条
  • [1] Radial artery cannulation for coronary angiography and angioplasty results in sustained impairment of radial artery function
    Burstein, JM
    Gidrewicz, D
    Hutchison, SJ
    Holmes, K
    Cantor, WJ
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (7A): : 102H - 102H
  • [2] Radial artery cannulation for coronary angiography and angioplasty results in sustained impairment of radial artery function
    Burstein, JM
    Gidrewicz, D
    Hutchison, SJ
    Holmes, K
    Cantor, WJ
    CIRCULATION, 2005, 112 (17) : U750 - U750
  • [3] Impact of radial artery cannulation on radial artery function
    Cardoso, Cristiano O.
    Rodrigues, La Hore C.
    Cardoso, Carlos R.
    Yordi, Luis Maria C.
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (04): : 743 - 744
  • [4] The Effects of the Radial Coronary Angiography on the Radial Artery Patency
    Aydinalp, Alp
    Ozcalik, Emre
    AMERICAN JOURNAL OF CARDIOLOGY, 2017, 119 (08): : E84 - E84
  • [5] Vasospasms of the radial artery after the transradial approach for coronary angiography and angioplasty
    Fukuda, N
    Iwahara, S
    Harada, A
    Yokoyama, S
    Akutsu, K
    Takano, M
    Kobayashi, A
    Kurokawa, S
    Izumi, T
    JAPANESE HEART JOURNAL, 2004, 45 (05): : 723 - 731
  • [6] CANNULATION OF RADIAL ARTERY
    HAMER, JD
    MATHEWS, ET
    HARDMAN, J
    LANCET, 1974, 1 (7869): : 1282 - 1282
  • [7] RADIAL ARTERY CANNULATION
    BOBA, A
    ANAESTHESIA AND INTENSIVE CARE, 1978, 6 (04) : 361 - 361
  • [8] CANNULATION OF RADIAL ARTERY
    WYATT, R
    GLAVES, I
    COOPER, DJ
    LANCET, 1974, 2 (7873): : 156 - 156
  • [9] RADIAL ARTERY CANNULATION
    MOSES, JA
    CONNECTICUT MEDICINE, 1979, 43 (06) : 403 - 403
  • [10] CANNULATION OF RADIAL ARTERY
    RAVIN, M
    KIRBY, R
    LANCET, 1974, 2 (7874): : 225 - 225