Signal-to-Noise Contribution of Principal Component Loads in Reconstructed Near-Infrared Raman Tissue Spectra

被引:13
|
作者
Grimbergen, M. C. M. [1 ,2 ]
van Swol, C. F. P. [3 ]
Kendall, C. [4 ]
Verdaasdonk, R. M. [2 ]
Stone, N. [4 ]
Bosch, J. L. H. R. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Urol, Utrecht, Netherlands
[2] Univ Med Ctr, Dept Med Technol & Clin Phys, Utrecht, Netherlands
[3] St Antonius Hosp, Dept Med Phys, Nieuwegein, Netherlands
[4] Gloucestershire Hosp NHS Fdn Trust, Biophoton Res Unit, Gloucester, England
关键词
Signal-to-noise ratio; SNR; Principal component analysis; PCA; Raman spectroscopy; Bladder; IN-VIVO; SPECTROSCOPY; DIAGNOSIS; CANCER;
D O I
10.1366/000370210790572052
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The overall quality of Raman spectra in the near-infrared region, where biological samples are often studied, has benefited from various improvements to optical instrumentation over the past decade. However, obtaining ample spectral quality for analysis is still challenging due to device requirements and short integration times required for (in vivo) clinical applications of Raman spectroscopy. Multivariate analytical methods, such as principal component analysis (PCA) and linear discriminant analysis (LDA), are routinely applied to Raman spectral datasets to develop classification models. Data compression is necessary prior to discriminant analysis to prevent or decrease the degree of over-fitting. The logical threshold for the selection of principal components (PCs) to be used in discriminant analysis is likely to be at a point before the PCs begin to introduce equivalent signal and noise and, hence, include no additional value. Assessment of the signal-to-noise ratio (SNR) at a certain peak or over a specific spectral region will depend on the sample measured. Therefore, the mean SNR over the whole spectral region (SNRmsr) is determined in the original spectrum as well as for spectra reconstructed from an increasing number of principal components. This paper introduces a method of assessing the influence of signal and noise from individual PC loads and indicates a method of selection of PCs for LDA. To evaluate this method, two data sets with different SNRs were used. The sets were obtained with the same Raman system and the same measurement parameters on bladder tissue collected during white light cystoscopy (set A) and fluorescence-guided cystoscopy (set B). This method shows that the mean SNR over the spectral range in the original Raman spectra of these two data sets is related to the signal and noise contribution of principal component loads. The difference in mean SNR over the spectral range can also be appreciated since fewer principal components can reliably be used in the low SNR data set (set B) compared to the high SNR data set (set A). Despite the fact that no definitive threshold could be found, this method may help to determine the cutoff for the number of principal components used in discriminant analysis. Future analysis of a selection of spectral databases using this technique will allow optimum thresholds to be selected for different applications and spectral data quality levels.
引用
收藏
页码:8 / 14
页数:7
相关论文
共 50 条
  • [1] A COMPARISON OF SIGNAL-TO-NOISE RATIOS FOR NEAR-INFRARED DETECTORS
    FREEMAN, JE
    HIEFTJE, GM
    APPLIED SPECTROSCOPY, 1984, 38 (06) : 837 - 843
  • [2] Optimization of the phase and modulation depth signal-to-noise ratio for near-infrared spectroscopy of the biological tissue
    Toronov, V
    D'Amico, E
    Hueber, D
    Gratton, E
    Barbieri, B
    Webb, A
    SARATOV FALL MEETING 2003: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE V, 2004, 5474 : 281 - 284
  • [3] Method for leveling the signal-to-noise ratio in multichannel functional near-infrared spectroscopy
    Yamada, Toru
    Umeyama, Shinji
    Kamoshida, Atsushi
    NEURAL IMAGING AND SENSING, 2017, 10051
  • [4] Signal-to-noise ratio of a near-infrared static wind imaging Michelson interferometer
    Zhang, Chunmin
    Wang, Yixuan
    Yan, Tingyu
    He, Yifan
    Sun, Yongqiang
    APPLIED OPTICS, 2021, 60 (16) : 4848 - 4855
  • [5] Optimization of Near-Infrared Spectroscopic Process Monitoring at Low Signal-to-Noise Ratio
    Schneider, Hendrik
    Reich, Gabriele
    ANALYTICAL CHEMISTRY, 2011, 83 (06) : 2172 - 2178
  • [6] Practicality of wavelength selection to improve signal-to-noise ratio in near-infrared spectroscopy
    Sato, H
    Kiguchi, M
    Kawaguchi, F
    Maki, A
    NEUROIMAGE, 2004, 21 (04) : 1554 - 1562
  • [7] PREDICTION OF FORAGE DIGESTIBILITY BY PRINCIPAL COMPONENT ANALYSIS OF NEAR-INFRARED REFLECTANCE SPECTRA
    ROBERT, P
    BERTRAND, D
    DEMARQUILLY, C
    ANIMAL FEED SCIENCE AND TECHNOLOGY, 1986, 16 (03) : 215 - 224
  • [8] Principal component analysis of near-infrared spectra of alteration products in calcareous samples
    Bacci, M
    Porcinai, S
    Radicati, B
    APPLIED SPECTROSCOPY, 1997, 51 (05) : 700 - 706
  • [9] Principal component regression of near-infrared reflectance spectra for beef tenderness prediction
    Park, B.
    Chen, Y.R.
    Hruschka, W.R.
    Shackelford, S.D.
    Koohmaraie, M.
    Transactions of the American Society of Agricultural Engineers, 2001, 44 (03): : 609 - 615
  • [10] Principal component regression of near-infrared reflectance spectra for beef tenderness prediction
    Park, B
    Chen, YR
    Hruschka, WR
    Shackelford, SD
    Koohmaraie, M
    TRANSACTIONS OF THE ASAE, 2001, 44 (03): : 609 - 615