Chromosome analysis and sorting

被引:16
|
作者
Dolezel, Jaroslav [1 ]
Lucretti, Sergio [2 ]
Molnar, Istvan [1 ]
Capal, Petr [1 ]
Giorgi, Debora [2 ]
机构
[1] Czech Acad Sci, Inst Expt Bot, Ctr Reg Hana Biotechnol & Agr Res, Slechtitelu 31, CZ-77900 Olomouc, Czech Republic
[2] Italian Natl Agcy New Technol Energy & Sustainabl, Div Biotechnol & Agroind, Rome, Italy
关键词
cell cycle synchronization; mitotic metaphase chromosomes; liquid chromosome suspension; DNA isolation; DNA amplification; gene mapping and cloning; genome sequencing; marker development; repetitive DNA labelling; FLOW-CYTOMETRIC ANALYSIS; METAPHASE CHROMOSOMES; BREAD WHEAT; IN-SITU; MITOTIC CHROMOSOMES; PLANT CHROMOSOMES; RUST RESISTANCE; SEX-CHROMOSOME; WILD RELATIVES; DNA LIBRARIES;
D O I
10.1002/cyto.a.24324
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Flow cytometric analysis and sorting of plant mitotic chromosomes has been mastered by only a few laboratories worldwide. Yet, it has been contributing significantly to progress in plant genetics, including the production of genome assemblies and the cloning of important genes. The dissection of complex genomes by flow sorting into the individual chromosomes that represent small parts of the genome reduces DNA sample complexity and streamlines projects relying on molecular and genomic techniques. Whereas flow cytometric analysis, that is, chromosome classification according to fluorescence and light scatter properties, is an integral part of any chromosome sorting project, it has rarely been used on its own due to lower resolution and sensitivity as compared to other cytogenetic methods. To perform chromosome analysis and sorting, commercially available electrostatic droplet sorters are suitable. However, in order to resolve and purify chromosomes of interest the instrument must offer high resolution of optical signals as well as stability during long runs. The challenge is thus not the instrumentation, but the adequate sample preparation. The sample must be a suspension of intact mitotic metaphase chromosomes and the protocol, which includes the induction of cell cycle synchrony, accumulation of dividing cells at metaphase, and release of undamaged chromosomes, is time consuming and laborious and needs to be performed very carefully. Moreover, in addition to fluorescent staining chromosomal DNA, the protocol may include specific labelling of DNA repeats to facilitate discrimination of particular chromosomes. This review introduces the applications of chromosome sorting in plants, and discusses in detail sample preparation, chromosome analysis and sorting to achieve the highest purity in flow-sorted fractions, and their suitability for downstream applications.
引用
收藏
页码:328 / 342
页数:15
相关论文
共 50 条
  • [1] PLANT CHROMOSOME ANALYSIS AND SORTING BY FLOW CYTOMETRY
    DOLEZEL, J
    LUCRETTI, S
    SCHUBERT, I
    CRITICAL REVIEWS IN PLANT SCIENCES, 1994, 13 (03) : 275 - 309
  • [2] Mammalian Chromosome Analysis and Sorting by Flow Cytometry
    Mukhopadhyay, Risani
    Varshitha, Dv
    Telford, William G.
    Sanders, Claire K.
    Chakraborty, Uttara
    CURRENT PROTOCOLS, 2023, 3 (05):
  • [3] Chromosome Analysis and Sorting Using Conventional Flow Cytometers
    Ng, Bee Ling
    CURRENT PROTOCOLS, 2023, 3 (03):
  • [4] Chromosome sorting for the masses?
    Monard, Simon
    CYTOMETRY PART A, 2016, 89A (09) : 797 - 798
  • [5] The impact of chromosome sorting and painting on the comparative analysis of primate genomes
    Ferguson-Smith, MA
    Yang, F
    Rens, W
    O'Brien, PCM
    CYTOGENETIC AND GENOME RESEARCH, 2005, 108 (1-3) : 112 - 121
  • [6] Genetic Analysis by Chromosome Sorting and Painting: Phylogenetic and Diagnostic Applications
    Malcolm A. Ferguson-Smith
    European Journal of Human Genetics, 1997, 5 (5) : 253 - 265
  • [7] Chromosome sorting in tetraploid wheat and its potential for genome analysis
    Kubaláková, M
    Kovárová, P
    Suchánková, P
    Cíhalíková, J
    Bartos, J
    Lucretti, S
    Watanabe, N
    Kianian, SF
    Dolezel, J
    GENETICS, 2005, 170 (02) : 823 - 829
  • [8] Genetic analysis by chromosome sorting and painting: Phylogenetic and diagnostic applications
    FergusonSmith, MA
    EUROPEAN JOURNAL OF HUMAN GENETICS, 1997, 5 (05) : 253 - 265
  • [9] Chromosome analysis and sorting in Vicia sativa using flow cytometry
    Kovarova, P.
    Navratilova, A.
    Macas, J.
    Dolezel, J.
    BIOLOGIA PLANTARUM, 2007, 51 (01) : 43 - 48
  • [10] Sorting out chromosome errors
    Cohen, J
    SCIENCE, 2002, 296 (5576) : 2164 - 2166