Feasibility and diagnostic accuracy of whole heart coronary MR angiography using free-breathing 3D balanced turbo-field-echo with SENSE and the half-Fourier acquisition technique

被引:11
|
作者
Kim, Young Jin
Seo, Jae-Seung
Choi, Byoung Wook
Choe, Kyu Ok
Jang, Yangsoo
Ko, Young-Guk
机构
[1] Yonsei Univ, Severance Hosp, Coll Med, Dept Radiol, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Yonsei Cardiovasc Ctr, Div Cardiovasc, Seoul 120752, South Korea
[3] Yonsei Univ, Coll Med, Cardiovasc Res Inst, Seoul 120752, South Korea
关键词
coronary angiography; magnetic resonance (MR); angiography;
D O I
10.3348/kjr.2006.7.4.235
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: We wanted to assess the feasibility and diagnostic accuracy of whole heart coronary magnetic resonance angiography (MRA) with using 3D balanced turbo-field-echo (b-TFE) with SENSE and the half-Fourier acquisition technique for identifying stenoses of the coronary artery. Materials and Methods: Twenty-one patients who underwent both whole heart coronary MRA examinations and conventional catheter coronary angiography examinations were enrolled in the study. The whole heart coronary MRA images were acquired using a navigator gated 3D b-TFE sequence with SENSE and the half-Fourier acquisition technique to reduce the acquisition time. The imaging slab covered the whole heart (80 contiguous slices with a reconstructed slice thickness of 1.5 mm) along the transverse axis. The quality of the images was evaluated by using a 5-point scale (0 - uninterpretable, 1 - poor, 2 - fair, 3 - good, 4 - excellent). Ten coronary segments of the heart were evaluated in each case; the left main coronary artery (LM), and the proximal, middle and distal segments of the left anterior descending (LAD), the left circumflex (LCX) and the right coronary artery (RCA). The diagnostic accuracy of whole heart coronary MRA for detecting significant coronary artery stenosis was determined on the segment-by-segment basis, and it was compared with the results obtained by conventional catheter angiography, which is the gold standard. Results: The mean image quality was 3.7 in the LM, 3.2 in the LAD, 2.5 in the LCX, and 3.3 in the RCA, respectively (the overall image quality was 3.0 +/- 0.1). 168 (84%) of the 201 segments had an acceptable image quality (>= grade 2). The sensitivity, specificity, accuracy, negative predictive value and positive predictive value of the whole heart coronary MRA images for detecting significant stenosis were 81.3%, 92.1%, 91.1%, 97.9%, and 52.0%, respectively. The mean coronary MRA acquisition time was 9 min 22 sec (+/- 125 sec). Conclusion: Whole heart coronary MRA is a feasible technique, and it has good potential to evaluate the major portions of the coronary arteries with an acceptable image quality within a reasonable scan time.
引用
收藏
页码:235 / 242
页数:8
相关论文
共 23 条
  • [1] MR imaging of coronary arteries: noncontrast free-breathing whole heart acquisition with ultrafast 3D balanced gradient-echo technique
    Auger, F.
    Willoteaux, S.
    Lions, C.
    Negaiwi, Z.
    Gengler, L.
    Midulla, M.
    Akkari, K.
    Beregi, J. P.
    JOURNAL DE RADIOLOGIE, 2010, 91 (01): : 78 - 81
  • [2] Fast isotropic volumetric coronary MR angiography using free-breathing 3D radial balanced FFE acquisition
    Stehning, C
    Börnert, P
    Nehrke, K
    Eggers, H
    Dössell, O
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) : 197 - 203
  • [3] Influence of Applying Nitroglycerin in Whole-Heart Free-Breathing 3D Coronary MR Angiography
    Jin, Hang
    Zeng, Meng-Su
    Ge, Mei-Ying
    Ma, Jian-Ying
    Chen, Cai-Zhong
    Shen, Ji-Zhang
    Li, Ren-Chen
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) : 927 - 932
  • [4] A study of in vitro and in vivo MR of free-breathing whole-heart 3D coronary angiography using parallel imaging
    Hang Jin
    Meng-Su Zeng
    Mei-Ying Ge
    Shan Yang
    Cai-Zhong Chen
    Ji-Zhang Shen
    Ren-Chen Li
    The International Journal of Cardiovascular Imaging, 2009, 25 : 121 - 129
  • [5] A study of in vitro and in vivo MR of free-breathing whole-heart 3D coronary angiography using parallel imaging
    Jin, Hang
    Zeng, Meng-Su
    Ge, Mei-Ying
    Yang, Shan
    Chen, Cai-Zhong
    Shen, Ji-Zhang
    Li, Ren-Chen
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 : 121 - 129
  • [6] A noncontrast enhanced MR angiography technique using ECG-Synchronized 3D half-fourier fast spin echo
    Miyazaki, M
    Tateishi, F
    Sugiura, S
    Abe, H
    Kassai, Y
    RADIOLOGY, 1999, 213P : 139 - 139
  • [7] Single-Breath-Hold Whole-heart Unenhanced Coronary MRA Using Multi-shot Gradient Echo EPI at 3T: Comparison with Free-breathing Turbo-field-echo Coronary MRA on Healthy Volunteers
    Iyama, Yuji
    Nakaura, Takeshi
    Nagayama, Yasunori
    Oda, Seitaro
    Utsunomiya, Daisuke
    Kidoh, Masafumi
    Yuki, Hideaki
    Hirata, Kenichiro
    Namimoto, Tomohiro
    Kitajima, Mika
    Morita, Kosuke
    Funama, Yoshinori
    Takemura, Atsushi
    Okuaki, Tomoyuki
    Yamashita, Yasuyuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2018, 17 (02) : 161 - 167
  • [8] Non-contrast-enhanced MR angiography using 3D ECG-synchronized half-Fourier fast spin echo
    Miyazaki, M
    Sugiura, S
    Tateishi, F
    Wada, H
    Kassai, Y
    Abe, H
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 12 (05) : 776 - 783
  • [9] 2117 High-resolution 3D free-breathing coronary MR angiography using wideband SSFP at 3 Tesla
    Hsu-Lei Lee
    Ajit Shankaranarayanan
    Gerald M Pohost
    Krishna S Nayak
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [10] High-spatial-resolution 3D balanced turbo field-echo technique for MR angiography of the renal arteries: Initial experience
    Coenegrachts, KL
    Hoogeveen, RM
    Vaninbroukx, JA
    Bosmans, HT
    Bielen, DJ
    Maleux, G
    Maes, F
    Hamaekers, P
    Oyen, RH
    Marchal, GJ
    RADIOLOGY, 2004, 231 (01) : 237 - 242