Enhancement of microbeam x-ray fluorescence analysis using monolithic polycapillary focusing optics

被引:34
|
作者
Gao, N
Ponomarev, IY
Xiao, QF
Gibson, WM
Carpenter, DA
机构
[1] XRAY OPT SYST INC,ALBANY,NY 12205
[2] OAK RIDGE CTR MFG TECHNOL,OAK RIDGE,TN 37831
关键词
D O I
10.1063/1.120360
中图分类号
O59 [应用物理学];
学科分类号
摘要
A monolithic polycapillary focusing optic was tested in the microbeam x-ray fluorescence system at the Oak Ridge Center for Manufacturing Technology. The optic was designed to cover a wide energy range from 4 keV to 20 keV. The focal spot size of the output beam at 17.4 keV (Mo K alpha) was measured to be 21 mu m full width of half maximum. An average beam intensity of 1.5 x 10(5) photon/s/mu m(2) was obtained at the focus for Mo K alpha line using a 12 W microfocus x-ray source, This intensity is about 2400 times over that of a direct beam at 100 mm away from the x-ray source. The small, intense x-ray beam obtained was used to analyze and map the compositions of different elements in industrial samples. (C) 1997 American Institute of Physics.
引用
收藏
页码:3441 / 3443
页数:3
相关论文
共 50 条
  • [1] Monolithic polycapillary focusing optics and their applications in microbeam x-ray fluorescence
    Gao, N
    Ponomarev, IY
    Xiao, QF
    Gibson, WM
    Carpenter, DA
    [J]. APPLIED PHYSICS LETTERS, 1996, 69 (11) : 1529 - 1531
  • [2] The monolithic X-ray polycapillary lens and its application in microbeam X-ray fluorescence
    Xie, JD
    He, YJ
    Ding, XL
    Pan, QL
    Yan, YM
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (03) : 391 - 394
  • [3] Study of the monolithic x-ray focusing lens and its application in microbeam x-ray fluorescence analysis
    Xie, JD
    Yan, YM
    Ding, XL
    He, YJ
    Pan, QL
    [J]. X-RAY SPECTROMETRY, 2000, 29 (04) : 305 - 309
  • [4] Performances of synchrotron radiation microbeam focused by monolithic half focusing polycapillary X-ray lens
    Sun, Tianxi
    Liu, Zhiguo
    He, Bo
    Wei, Shiqiang
    Xie, Yaning
    Liu, Tao
    Hu, Tiandou
    Ding, Xunliang
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 574 (02): : 285 - 288
  • [5] X-Ray Fluorescence Technology Based on Monolithic Polycapillary X-Ray Focusing Lens in Helium Atmosphere
    Li Hui-quan
    Sun Xue-peng
    Shao Shang-kun
    Yuan Tian-yu
    Hua Lu
    Zhong Yu-chuan
    Liu Zhi-guo
    Sun Tian-xi
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44 (08) : 2198 - 2201
  • [6] X-ray fluorescence imaging with polycapillary X-ray optics
    Yonehara, Tasuku
    Yamaguchi, Makoto
    Tsuji, Kouichi
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (06) : 441 - 444
  • [7] X-ray fluorescence analysis on the base of polycapillary Kumakhov optics
    Nikitina, SV
    Shcherbakov, AS
    Ibraimov, NS
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (07): : 2950 - 2956
  • [8] Analysis of powder X-ray diffraction resolution using collimating and focusing polycapillary optics
    Zhou, Wei
    Mahato, Dip N.
    MacDonald, C. A.
    [J]. THIN SOLID FILMS, 2010, 518 (18) : 5047 - 5056
  • [9] Micro Energy Dispersive X-Ray Diffraction Analysis by Polycapillary X-Ray Optics Focusing
    Duan Zeming
    Jiang Qili
    Liu Jun
    Pan Qiuli
    Cheng Lin
    [J]. ACTA OPTICA SINICA, 2018, 38 (12)
  • [10] A micro X-ray fluorescence analysis method using polycapillary X-ray optics and grazing exit geometry
    Yang, Jun
    Tsuji, Kouichi
    Lin, Xiaoyan
    Han, Dongyan
    Ding, Xunliang
    [J]. THIN SOLID FILMS, 2009, 517 (11) : 3357 - 3361