Performance of the OptiMAL malaria antigen capture dipstick for malaria diagnosis and treatment monitoring at the Hospital for Tropical Diseases, London

被引:89
|
作者
Moody, A [1 ]
Hunt-Cooke, A [1 ]
Gabbett, E [1 ]
Chiodini, P [1 ]
机构
[1] Hosp Trop Dis, Dept Clin Parasitol, London WC1E 6AU, England
关键词
OptiMAL; pLDH; Plasmodium; sensitivity; specificity;
D O I
10.1046/j.1365-2141.2000.01974.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We report here the sensitivity and specificity of OptiMAL for the diagnosis of acute malaria in patients presenting to the Hospital for Tropical Diseases (HTD), a tertiary referral centre for Tropical and Infectious diseases. A sensitivity of 95.3% and a specificity of 100% for Plasmodium falciparum and a sensitivity of 96% and a specificity of 100% for Plasmodium vivax was obtained. The ability to follow the course of the parasitaemia using OptiMAL during treatment and its significance for use in areas where expert microscopy is not available is discussed.
引用
收藏
页码:891 / 894
页数:4
相关论文
共 50 条
  • [1] A rapid dipstick antigen capture assay for the diagnosis of falciparum malaria
    Banchongaksorn, T
    Hurtado, AJC
    Chauhan, V
    Dietz, R
    Kodisinghe, HM
    Swe, M
    Payne, D
    Perrone, J
    Rooney, W
    Sharma, RS
    Sharma, VP
    Singh, N
    Aung
    Soerjosembodo, S
    Thimasarn, K
    Ache, AR
    Meek, S
    Suresh, K
    Arbani, PR
    Beljaev, AE
    Kondrachine, AV
    Hoyer, S
    Montanari, RM
    Orlov, VS
    Trigg, PI
    BULLETIN OF THE WORLD HEALTH ORGANIZATION, 1996, 74 (01) : 47 - 54
  • [2] DIPSTICK ANTIGEN-CAPTURE ASSAY FOR MALARIA DETECTION
    PEYRON, F
    MARTET, G
    VIGIER, JP
    LANCET, 1994, 343 (8911): : 1502 - 1503
  • [3] Evaluation of OptiMAL™, a dipstick test for the diagnosis of malaria
    John, SM
    Sudarsanam, A
    Sitaram, U
    Moody, AH
    ANNALS OF TROPICAL MEDICINE AND PARASITOLOGY, 1998, 92 (05): : 621 - 622
  • [4] The ParaSight(TM)-F rapid dipstick antigen capture assay for monitoring parasite clearance after drug treatment of Plasmodium falciparum malaria
    DiPerri, G
    Olliaro, P
    Nardi, S
    Allegranzi, B
    Deganello, R
    Vento, S
    Lanzafame, M
    Cazzadori, A
    Bonora, S
    Concia, E
    TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 1997, 91 (04) : 403 - 405
  • [5] DIAGNOSIS OF MALARIA BY DETECTION OF PLASMODIUM-FALCIPARUM HRP-2 ANTIGEN WITH A RAPID DIPSTICK ANTIGEN-CAPTURE ASSAY
    BEADLE, C
    LONG, GW
    WEISS, WR
    MCELROY, PD
    MARET, SM
    OLOO, AJ
    HOFFMAN, SL
    LANCET, 1994, 343 (8897): : 564 - 568
  • [6] ParaSight-F dipstick antigen test in the diagnosis of Falciparum malaria in Ethiopia
    Mengesha, T
    Gebreselassie, H
    Mohammed, H
    Assefa, T
    Woldemichael, T
    EAST AFRICAN MEDICAL JOURNAL, 1999, 76 (11) : 626 - 629
  • [7] Performance of the OptiMAL dipstick test for management of severe and complicated malaria cases in a tertiary hospital, Central India
    Singh, N
    Nagpal, AC
    JOURNAL OF INFECTION, 2004, 48 (04) : 364 - 365
  • [8] Evaluation of a rapid antigen capture assay for the diagnosis of falciparum malaria
    Mishra, B
    Samantaray, JC
    Mirdha, BR
    INDIAN JOURNAL OF MEDICAL RESEARCH, 1999, 109 : 16 - 19
  • [9] Feasibility of a rapid dipstick antigen-capture assay for self-testing of travellers' malaria
    Trachsler, M
    Schlagenhauf, P
    Steffen, R
    TROPICAL MEDICINE & INTERNATIONAL HEALTH, 1999, 4 (06) : 442 - 447
  • [10] Performance of BinaxNOW for Diagnosis of Malaria in a US Hospital
    DiMaio, Michael A.
    Pereira, Irma T.
    George, Tracy I.
    Banaei, Niaz
    JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (09) : 2877 - 2880