Snare-assisted thoracic endovascular aortic repair for redirection of a false lumen elephant trunk

被引:3
|
作者
Chen, Julia Fayanne [1 ,2 ]
Mangi, Abeel [3 ]
Vallabhajosyula, Prashanth [2 ,3 ]
Nassiri, Naiem [1 ,2 ]
机构
[1] Yale New Haven Med Ctr, Dept Surg, Div Vasc & Endovasc Surg, 20 York St, New Haven, CT 06504 USA
[2] Yale New Haven Med Ctr, Aort Inst, 20 York St, New Haven, CT 06504 USA
[3] Yale Univ, Sch Med, Div Cardiac Surg, Dept Surg, New Haven, CT 06520 USA
关键词
Aortic dissection; TEVAR; False lumen; Elephant trunk; Snare; FENESTRATION; DEPLOYMENT; ARCH;
D O I
10.1016/j.jvscit.2020.08.008
中图分类号
R61 [外科手术学];
学科分类号
摘要
In recent years, a hybrid approach to the classic two-stage elephant trunk technique has come into favor for treatment of thoracic aortic dissection. During the first stage, inadvertent intraoperative placement of the elephant trunk into the false lumen can occur on rare occasions, resulting in untoward difficulties during the second stage of the procedure. We describe here a snare-assisted technique for endovascular salvage of an elephant trunk that had inadvertently been placed in the false lumen of a chronic aortic dissection.
引用
收藏
页码:566 / 570
页数:5
相关论文
共 50 条
  • [1] Trans-sternotomy, snare-assisted thoracic endovascular aortic repair for redirection of a migrated elephant trunk
    Fereydooni, Soraya
    Amabile, Andrea
    Nassiri, Naiem
    Vallabhajosyula, Prashanth
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2023, 9 (01):
  • [2] Bail-out thoracic endovascular aortic repair for incorrect deployment of frozen elephant trunk into the false lumen
    Kawashima, Motoharu
    Nomura, Yoshikatsu
    Matsumori, Masamichi
    Murakami, Hirohisa
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2020, 30 (06) : 947 - 949
  • [3] Thoracic endovascular aortic repair (TEVAR) to retrieve a stented elephant trunk graft entrapped in the false lumen of dissection patients
    Gao, Hui-Qiang
    Zhang, Hong-Kai
    Xu, Shang-Dong
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (10) : 3426 - 3427
  • [4] Thoracic Endovascular Aortic Repair into the False Lumen in Chronic Aortic Dissection
    Kamman, Arnoud V.
    Williams, David M.
    Patel, Himanshu J.
    ANNALS OF VASCULAR SURGERY, 2017, 42 : 303.e11 - 303.e14
  • [5] Endovascular rescue of an elephant trunk initially positioned in the false lumen of an aortic dissection
    Crunelle, Benjamin
    Martin-Gonzalez, Teresa
    Vincentelli, Andre
    Haulon, Stephan
    JOURNAL OF VASCULAR SURGERY, 2016, 64 (01) : 235 - 235
  • [6] Transapical access for thoracic endovascular aortic repair to elephant trunk completion
    Agostinelli, Andrea
    Carino, Davide
    Borrello, Bruno
    Nicolini, Francesco
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2018, 27 (02) : 301 - 303
  • [7] False Lumen Volume Is A Predictor Of Successful Thoracic Endovascular Aortic Repair
    Khabaz, Kameel
    Sankary, Seth
    Milner, Ross
    Pocivavsek, Luka
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2021, 41
  • [8] Hybrid Repair for Ruptured Thoracic Aortic Aneurysm: Frozen Elephant Trunk Technique with Thoracic Endovascular Aortic Repair
    Yamane, Yoshitaka
    Hiraoka, Toshifumi
    Mochizuki, Shingo
    Furukawa, Tomokuni
    Yamada, Kazunori
    ANNALS OF VASCULAR DISEASES, 2018, 11 (02) : 236 - 238
  • [9] Endovascular rescue for malpositioned frozen elephant trunk into the false lumen
    Takagi, Daichi
    Wada, Takuya
    Igarashi, Wataru
    Kadohama, Takayuki
    Kiryu, Kentaro
    Arai, Takeshi
    Yamamoto, Hiroshi
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (10) : 3948 - 3951
  • [10] Transapical thoracic endovascular aortic repair with a frozen elephant trunk for thoracic aortic aneurysm with shaggy aorta
    Wakabayashi, Naohiro
    Kikuchi, Yuta
    Shibagaki, Keisuke
    Kamiya, Hiroyuki
    JTCVS TECHNIQUES, 2021, 8 : 33 - 36