Migration of cemented femoral components after THR - Roentgen stereophotogrammetric analysis

被引:34
|
作者
Kiss, J [1 ]
Murray, DW [1 ]
TurnerSmith, AR [1 ]
Bithell, J [1 ]
Bulstrode, CJ [1 ]
机构
[1] UNIV OXFORD, NUFFIELD ORTHOPAED CTR, NUFFIELD DEPT ORTHOPAED SURG, OXFORD OX3 7LD, ENGLAND
来源
关键词
D O I
10.1302/0301-620X.78B5.0780796
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We studied the migration of 58 cemented Hinek femoral components for total hip replacement, using roentgen stereophotogrammetric analysis over four years, The implants migrated faster during the first year than subsequently, and the pattern of migration in the second period was very different. During the first year they subsided, tilted into varus and internally rotated. After this there was slow distal migration with no change in orientation. None of the prostheses has Set failed. The early migration is probably caused by resorption of bone damaged by surgical trauma or the heat generated by the polymerisation of bone cement. Later migration may be due to creep in the bone cement or the surrounding fibrous membrane. The prosthesis which we studied allows the preservation of some of the femoral neck, and comparison with published migration studies of the Charnley stem suggests that this decreases rotation and may help to prevent loosening.
引用
收藏
页码:796 / 801
页数:6
相关论文
共 50 条
  • [1] EARLY LOOSENING OF FEMORAL COMPONENTS AFTER CEMENTED REVISION - A ROENTGEN STEREOPHOTOGRAMMETRIC STUDY
    FRANZEN, H
    MJOBERG, B
    ONNERFALT, R
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (05): : 721 - 724
  • [2] Estimation of the migration of tibial components in total knee arthroplasty - A roentgen stereophotogrammetric analysis
    Fukuoka, S
    Yoshida, K
    Yamano, Y
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (02): : 222 - 227
  • [3] MICROMOTION OF CONVENTIONALLY CEMENTED ALL-POLYETHYLENE TIBIAL COMPONENTS IN TOTAL KNEE REPLACEMENTS - A ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS OF MIGRATION AND INDUCIBLE DISPLACEMENT
    RYD, L
    LINDSTRAND, A
    ROSENQUIST, R
    SELVIK, G
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1987, 106 (02) : 82 - 88
  • [4] MIGRATION OF HYDROXYAPATITE-COATED FEMORAL PROSTHESES - A ROENTGEN STEREOPHOTOGRAMMETRIC STUDY
    SOBALLE, K
    TOKSVIGLARSEN, S
    GELINECK, J
    FRUENSGAARD, S
    HANSEN, ES
    RYD, L
    LUCHT, U
    BUNGER, C
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (05): : 681 - 687
  • [5] EARLY MIGRATION OF ACETABULAR COMPONENTS REVISED WITH CEMENT - A ROENTGEN STEREOPHOTOGRAMMETRIC STUDY
    FRANZEN, H
    MJOBERG, B
    ONNERFALT, R
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1993, (287) : 131 - 134
  • [6] ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS OF PROBLEMS AFTER HIP-ARTHROPLASTY - MIGRATION, LOOSENING, INSTABILITY
    HANSSON, LI
    EGUND, N
    MJOBERG, B
    MOGENSEN, B
    SELVIK, G
    ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (06): : 695 - 695
  • [7] ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS
    SELVIK, G
    ACTA RADIOLOGICA, 1990, 31 (02) : 113 - 126
  • [8] STABILITY OF FEMORAL-NECK FRACTURES - A POSTOPERATIVE ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS
    RAGNARSSON, JI
    HANSSON, LI
    KARRHOLM, J
    ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (03): : 283 - 287
  • [9] EARLY LOOSENING OF FEMORAL COMPONENTS AFTER CEMENTED REVISION - A ROENTGEN STEREOPHOTOGRAMMETRIC STUDY (J BONE JOINT SURG, VOL 74-B, PG 721, 1992)
    FRANZEN, H
    MJOBERG, B
    ONNERFALT, R
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (01): : 169 - 169
  • [10] SUBSIDENCE OF THE FEMORAL COMPONENT IN THE NONCEMENTED TOTAL HIP - A ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS
    WYKMAN, A
    SELVIK, G
    GOLDIE, I
    ACTA ORTHOPAEDICA SCANDINAVICA, 1988, 59 (06): : 635 - 637