Balloon-expandable stenting with and without coiling for wide-neck and complex aneurysms

被引:29
|
作者
Zenteno, Marco
Modenesi Freitas, Jose Maria [1 ]
Aburto-Murrieta, Yolanda
Koppe, Gelson
Machado, Elcio
Lee, Angel
机构
[1] Hosp Evangel, Dept Intervent Radiol, BR-80730150 Curitiba, Parana, Brazil
[2] Inst Nacl Neurol & Neurocirug, Dept Neurol Endovasc Therapy, Mexico City 14269, DF, Mexico
[3] Hosp Santa Rita, Dept Intervent Radiol, BR-04013004 Sao Paulo, Brazil
[4] Hosp Angeles Pedregal, Comprehens Stroke Ctr, Mexico City 10700, DF, Mexico
来源
SURGICAL NEUROLOGY | 2006年 / 66卷 / 06期
关键词
wide-neck aneurysms; stent-supported coiling; solely stenting; endovascular treatment; rate of occlusion;
D O I
10.1016/j.surneu.2006.05.058
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Wide-necked, saccular, dissecting, and fusiform intracranial aneurysms are poor coil retainers. Retention can be improved by parent-artery stenting across the aneurysm. Methods: We used a balloon-expandable stent and delivery system, intending to treat 38 aneurysms in 36 patients. Stents could not be advanced across the neck of 2 aneurysms near the ophthalmic artery origin. These cases were managed by temporary balloon remodeling and coiling. Stenting alone was done for 15 aneurysms, including 7 in vertebral artery V4 segments. Stenting with immediate or delayed coiling was done in 21 aneurysms. Results: Stenting alone caused immediate and complete obliteration of I treated aneurysm (7%), subtotal obliteration in 13 treated (86%) aneurysms, and was associated with I failure. Stenting and coiling yielded a significantly better 57% complete obliteration rate, 43% subtotal obliteration, and no failures. There were 5 complications: I wire perforation, 2 cavernous-carotid-sinus fistulae, and 2 partial in-stent thromboses. All were controlled or cleared with no long-term sequelae or deaths. Contrast imaging at 1 to 12 months was available for 30 patients (13 stent-only, 17 stent-pluscoiling), demonstrating complete obliteration in 25 (83%) and subtotal obliteration in 5. A total of 7 stent-only aneurysms (4 V4s) were completely obliterated, and 3 (all V4s) were; >= 90% obliterated. Conclusion: Stenting and coiling through the wall of the stent resulted in 88% (15/17) complete obliteration when imaged 1 to 12 months after treatment. Stenting alone effectively closed off V4-segment wide-necked aneurysms but was inferior to stenting and coiling in less mobile vessels. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:603 / 610
页数:8
相关论文
共 50 条
  • [1] Staged Stenting with or without Additional Coils after Conventional Initial Coiling of Acute Ruptured Wide-Neck Intracranial Aneurysms
    Feng, Zhengzhe
    Zuo, Qiao
    Yang, Pengfei
    Li, Qiang
    Zhao, Rui
    Hong, Bo
    Xu, Yi
    Huang, Qinghai
    Liu, Jianmin
    WORLD NEUROSURGERY, 2017, 108 : 506 - 512
  • [2] Need for Y-stenting in stent-assisted coiling of wide-neck bifurcation aneurysms*
    Lauzier, David C.
    Root, Brandon K.
    Chatterjee, Arindam R.
    Osbun, Joshua W.
    Moran, Christopher J.
    Kansagra, Akash P.
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2023, 229
  • [3] Endovascular Coiling of Wide-Neck and Wide-Neck Bifurcation Aneurysms: A Systematic Review and Meta-Analysis
    Zhao, B.
    Yin, R.
    Lanzino, G.
    Kallmes, D. F.
    Cloft, H. J.
    Brinjikji, W.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (09) : 1700 - 1705
  • [4] Antegrade horizontal stenting for endovascular coiling of wide-neck aneurysms in the basilar tip: Two case reports
    Baek, Byung Hyun
    Yoon, Woong
    Kim, You Sub
    Kim, Tae Sun
    Kim, Seul Kee
    Lee, Yun Young
    Lee, Byung Chan
    Park, Chan
    MEDICINE, 2025, 104 (05)
  • [5] Stent-Assisted Coiling Versus Balloon Remodeling of Wide-Neck Aneurysms: Comparison of Angiographic Outcomes
    Chalouhi, N.
    Starke, R. M.
    Koltz, M. T.
    Jabbour, P. M.
    Tjoumakaris, S. I.
    Dumont, A. S.
    Rosenwasser, R. H.
    Singhal, S.
    Gonzalez, L. F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (10) : 1987 - 1992
  • [6] "Y" and "X" Stent-Assisted Coiling of Complex and Wide-Neck Intracranial Bifurcation Aneurysms
    Bartolini, B.
    Blanc, R.
    Pistocchi, S.
    Redjem, H.
    Piotin, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (11) : 2153 - 2158
  • [7] Stent, balloon-assisted coiling and double microcatheter for treating wide-neck aneurysms in anterior cerebral circulation
    Pan, Jianwei
    Xiao, Feng
    Szeder, Viktor
    Yan, Ming
    Fan, Weijian
    Gu, Jun
    He, Lingna
    Zhan, Renya
    NEUROLOGICAL RESEARCH, 2013, 35 (10) : 1002 - 1008
  • [8] BALLOON-EXPANDABLE STENTING IN PEDIATRIC CARDIOLOGY
    OLAUGHLIN, MP
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1995, 8 (05) : 463 - 475
  • [9] Solitaire AB Stent-Assisted Coiling of Wide-Neck Micro Aneurysms
    Li, Xue-dong
    Qin, Jun
    Xiao, Zhen-yong
    Feng, Yi
    Chen, Jia-kang
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2016, 59 (04) : 341 - 345
  • [10] STENT REMODELING TECHNIQUE FOR COILING OF RUPTURED WIDE-NECK CEREBRAL ANEURYSMS: CASE REPORT
    Lopes, Demetrius K.
    Wells, Kalani
    NEUROSURGERY, 2009, 65 (05) : 1007 - 1008