Report on the APMP.PR-S6: 2012-2013 supplementary comparison of spectral radiance from 250 nm to 2500 nm

被引:2
|
作者
Shin, Dong-Joo [1 ]
Park, Seongchong [1 ]
Lee, Dong-Hoon [1 ]
Dai Caihong [2 ]
Wu Zhifeng [2 ]
Wang Yanfei [2 ]
Khlevnoy, Boris [3 ]
Solodilov, Maxim [3 ]
Kolesnikova, Svetlana [3 ]
机构
[1] KRISS, 267 Gajeong Ro, Daejeon 34113, South Korea
[2] NIM, 18 Bei San Huan Dong Lu, Beijing 100029, Peoples R China
[3] VNIIOFI, Ozernaya 46, Moscow 119361, Russia
关键词
D O I
10.1088/0026-1394/57/1A/02001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Korea Research Institute of Standards and Science (KRISS), National Institute of Metrology (NIM), and All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI) started an international comparison on the spectral radiance over the spectral region from 250 nm to 2500 nm in 2012 and completed all measurements in 2016. The aim of this comparison was to assess the equivalence of the spectral radiance scales between the three laboratories. This comparison was carried out according to the technical protocol listed in the KCDB under the identifier APMP.PR-S6. The difference from the reference value (RV) and its uncertainty of each participant of this comparison were calculated by using the relative difference model recommended by the Guidelines for CCPR Comparison Report Preparation. A method (ratio method) to calculate the difference from the RV and its uncertainty was proposed to eliminate the pilot effects involved in the relative difference model. In the ratio method, spectral radiance ratios to the pilot and geometric means were used to calculate the difference from the RV and its uncertainty of each participant. Results of this comparison analyzed using the ratio method showed that differences from the RV of all participants were within their uncertainties (k = 2) except a few wavelengths for each participant. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA). © 2020 Institute of Physics Publishing. All rights reserved.
引用
收藏
页数:3
相关论文
共 11 条
  • [1] CCPR-S1 Supplementary comparison for spectral radiance in the range of 220 nm to 2500 nm
    Khlevnoy, Boris
    Sapritsky, Victor
    Rougie, Bernard
    Gibson, Charles
    Yoon, Howard
    Gaertner, Arnold
    Taubert, Dieter
    Hartmann, Juergen
    METROLOGIA, 2009, 46 (04) : S174 - S180
  • [2] Final report on bilateral comparison APMP.PR-K1.a.1-2008 between KRISS (Korea) and VNIIOFI (Russia): Spectral irradiance from 250 nm to 2500 nm
    Shin, Dong-Joo
    Park, Chul-Woung
    Kolesnikova, Svetlana S.
    Khlevnoy, Boris B.
    METROLOGIA, 2010, 47
  • [3] Final report on the EURAMET.PR-K1.a-2009 comparison of spectral irradiance 250 nm-2500 nm
    Goodman, Teresa
    Servantes, William
    Woolliams, Emma
    Sperfeld, Peter
    Simionescu, Mihai
    Blattner, Peter
    Kallberg, Stefan
    Khlevnoy, Boris
    Dekker, Paul
    METROLOGIA, 2015, 52
  • [4] Final report on CCPR-S1: Spectral radiance 220 nm to 2500 nm
    Khlevnoy, Boris
    METROLOGIA, 2008, 45
  • [5] Bilateral Comparison of Spectral Irradiance Between NIM and VNIIOFI from 250 to 2500 nm
    Cai Hong Dai
    Boris Khlevnoy
    Zhi Feng Wu
    Yan Fei Wang
    Maxim Solodilov
    Svetlana Kolesnikova
    Irina Grigoryeva
    Yan Dong Lin
    Ling Li
    MAPAN, 2017, 32 : 243 - 250
  • [6] Bilateral Comparison of Spectral Irradiance Between NIM and VNIIOFI from 250 to 2500 nm
    Dai, Cai Hong
    Khlevnoy, Boris
    Wu, Zhi Feng
    Wang, Yan Fei
    Solodilov, Maxim
    Kolesnikova, Svetlana
    Grigoryeva, Irina
    Lin, Yan Dong
    Li, L.
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2017, 32 (03): : 243 - 250
  • [7] COOMET Supplementary Comparison COOMET.PR-S5 Spectral Regular Transmittance 250 nm to 635 nm (COOMET Project 429/CU/08)
    Valdés, Sandra Claudina Pedro
    Metrologia, 2023, 60 (1 A)
  • [8] CIPM key comparison CCPR-K1.a.2017 for spectral irradiance 250 nm to 2500 nm. Final report
    Khlevnoy B.B.
    Solodilov M.V.
    Kolesnikova S.S.
    Otryaskin D.A.
    Pons A.
    Campos J.
    Shin D.J.
    Park S.
    Obein G.
    Valin M.H.
    Vissière A.
    Dai C.
    Wu Z.
    Wang Y.
    Li L.
    Lin Y.
    Yoon H.
    Gibson C.
    Liu Y.
    Manson P.
    Atkinson E.
    Zama T.
    Shitomi H.
    Goodman T.
    Servantes W.
    Gamouras A.
    Woods D.J.
    Sperfeld P.
    Pape S.
    Metrologia, 2023, 60 (01)
  • [9] The CCPR K1-a key comparison of spectral irradiance from 250 nm to 2500 nm: measurements, analysis and results
    Woolliams, ER
    Fox, NP
    Cox, MG
    Harris, PM
    Harrison, NJ
    METROLOGIA, 2006, 43 (02) : S98 - S104
  • [10] EUROMET PR-K2.b Comparison on spectral responsivity (300 nm to 1 000 nm) Final Report 25 July 2013
    Campos, Joaquin
    METROLOGIA, 2013, 50