Evaluation of the Fetal Left Ventricular Myocardial Performance Index (MPI) by Using an Automated Measurement of Doppler Signals in Normal Pregnancies

被引:5
|
作者
Kim, Su-Min [1 ,2 ]
Ye, Soo-Young [2 ]
机构
[1] Busan Well High Womans Hosp, Dept Obstet, 95 Myeongji Ocean City 4 Ro, Busan 46764, South Korea
[2] Catholic Univ Pusan, Grad Sch, Dept Radiol Sci, 57 Oryun Daero, Busan 46252, South Korea
关键词
fetal ultrasound; fetal myocardial performance index (MPI); Tei index; K-index; cardiac interval; automatic detection; DIASTOLIC FUNCTION; REFERENCE RANGES; TEI INDEX; FETUSES; INFANTS; LIFE;
D O I
10.3390/diagnostics11020358
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The myocardial performance index is widely used as an indicator of the heart's performance. However, due to the subjective nature of ultrasonic testing, there are differences in the measurements among inspectors, requiring a quantitative and objective assessment. In this study, an automated program was developed to quantitatively evaluate the myocardial performance index (MPI) and the cardiac time intervals in the left ventricle for each trimester. One hundred and thirty-three pregnant women who visited the hospital for prenatal examinations were studied, and skilled inspectors obtained left ventricular blood flow waveforms from 47 fetuses in the 12 weeks, 54 fetuses in the 22 weeks, and 32 fetuses in the 31 weeks of pregnancy using a pulse Doppler mode of ultrasound equipment. The acquired images automatically measured the isovolumetric contraction time (IVCT), isovolumetric relaxation time (IVRT,) ejection time (ET), and filling time (FT), and calculated the Tei index (TI) and the K-index (KI); each interval was manually measured during the actual inspection for comparison. In this study, the ultrasonic Doppler waveform was objectively analyzed and measured by the automated program, and it will help with the evaluation of fetal heart function.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Automated measurement of fetal myocardial performance index in ultrasound Doppler waveforms
    Yoon, Heechul
    Lee, Hyuntaek
    Jeon, Kang-Won
    Jung, Haekyung
    Lee, Mi-Young
    Won, Hye-Sung
    Jeon, Eun-Jin
    Yang, Eun-Ho
    Choi, Jin-Young
    Hong, Soon-Jae
    MEDICAL IMAGING 2014: ULTRASONIC IMAGING AND TOMOGRAPHY, 2014, 9040
  • [2] Evaluation of an automated fetal myocardial performance index
    Welsh, A. W.
    Maheshwari, P.
    Wang, J.
    Henry, A.
    Chang, D.
    Crispi, F.
    Gardiner, H. M.
    Hernandez-Andrade, E.
    Meriki, N.
    Redmond, S.
    Yagel, S.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2016, 48 (04) : 496 - 503
  • [3] Feasibility of using Auto Mod-MPI system, a novel technique for automated measurement of fetal modified myocardial performance index
    Lee, M. -Y.
    Won, H. -S.
    Jeon, E. -J.
    Yoon, H. C.
    Choi, J. Y.
    Hong, S. J.
    Kim, M. -J.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2014, 43 (06) : 640 - 645
  • [4] Automated Measurement of Fetal Right-Myocardial Performance Index from Pulsed Wave Doppler Spectrum
    Suresh, Rahul
    Sivanandan, Srinivasan
    Singhal, Nitin
    Lee, JinYong
    Lee, Mi-Young
    Won, Hye-Sung
    MEDICAL IMAGING 2019: COMPUTER-AIDED DIAGNOSIS, 2019, 10950
  • [5] Learning curve for Doppler measurement of fetal modified myocardial performance index
    Cruz-Martinez, R.
    Figueras, F.
    Jaramillo, J. J.
    Meler, E.
    Mendez, A.
    Hernandez-Andrade, E.
    Gratacos, E.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2011, 37 (02) : 158 - 162
  • [6] Variable effect of preload reduction on left and right ventricular Myocardial Performance Index (MPI)
    Minczykowski, A.
    Zaremba-Drobnik, M.
    Pietrzak, I.
    Czekalski, S.
    Wysocki, H.
    EUROPEAN HEART JOURNAL, 2007, 28 : 488 - 489
  • [7] Index of myocardial performance using Doppler-derived parameters in the evaluation of left ventricular function in patients with essential hypertension
    Kang, SM
    Ha, JW
    Rim, SJ
    Chung, N
    YONSEI MEDICAL JOURNAL, 1998, 39 (05) : 446 - 452
  • [8] Fetal left ventricular myocardial performance index: Defining normal values for Indian population and a review of literature
    Nair, Anupama
    Radhakrishnan, Sitaraman
    ANNALS OF PEDIATRIC CARDIOLOGY, 2016, 9 (02) : 132 - 136
  • [9] Importance of the index of myocardial performance in evaluation of left ventricular function
    Dagdelen, S
    Eren, N
    Karabulut, H
    Caglar, N
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2002, 19 (04): : 273 - 278
  • [10] Technical Considerations for Measurement of the Fetal Left Modified Myocardial Performance Index
    Meriki, N.
    Welsh, A. W.
    FETAL DIAGNOSIS AND THERAPY, 2012, 31 (01) : 76 - 80