Evaluation of the IRMA TRUpoint and i-STAT creatinine assays

被引:18
|
作者
Nichols, James H.
Bartholomew, Cathy
Bonzagi, Arianna
Garb, Jane L.
Jin, Long
机构
[1] Baystate Hlth Syst, Clin Chem, Dept Surg, Springfield, MA 01199 USA
[2] Tufts Univ, Sch Med, Baystate Hlth Syst, Dept Pathol, Springfield, MA 01199 USA
关键词
IRMA TRUpoint analyzer; iSTAT analyzer; Jaffe creatinine; enzymatic creatinine; point-of-care testing; estimated GFR;
D O I
10.1016/j.cca.2006.09.024
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The i-STAT((R))(Abbott Diagnostics, East Windsor, NJ) and IRMA TRUpoint (TM) (ITC, Edison, NJ) POCT analyzers were evaluated in an oncology center. Methods: Precision and agreement with our core laboratory creatinine was judged by comparison of 50 consecutive chemotherapy patient results against the Roche rate-blanked Jaffe and enzymatic creatinine methods. Glomerular filtration rate (GFR) was estimated using the Cockroft-Gault (CG) calculation and Modification of Diet in Renal Disease Study (MDRD) equation. Results: Precision varied from 1% (enzymatic)-6.1% (TRUpoint). Correlation was good (r > 0.9948) with slopes within 5% of the Jaffe and enzymatic methods. Intercepts were < 15.9 mu mol/l (< 0.18 mg/dl), and statistically significant bias (p < 0.0025) was noted between the mean of patient specimens for i-STAT correlations to both the Jaffe and enzymatic laboratory creatinine methods. There was statistically significant concordance of estimated GFR between all methods, however, the agreement of estimated GFR to either the Jaffe or enzymatic creatinine laboratory methods was better for the TRUpoint (by either MDRD or CG estimation)and i-STAT (by MDRD equation) (Kappa > 0.60) than the i-STAT (by CG estimation) (Kappa = 0.41-0.60). Conclusion: Small biases in the calibration of analytical creatinine methods can lead to differences in clinical concordance using estimated GFR. Selecting an optimal POCT method depends on the institution's current creatinine method and tolerance for analytical performance and clinical concordance. (c) 2006 Elsevier B.V All rights reserved.
引用
收藏
页码:201 / 205
页数:5
相关论文
共 50 条
  • [1] Evaluation of i-STAT creatinine assay
    Gault, MH
    Seymour, ME
    Howell, WE
    NEPHRON, 2001, 88 (02): : 178 - 182
  • [2] Evaluation of the IRMA TRUpoint point-of-care creatinine assay
    Morris, M. C.
    Goldsmith, B. M.
    CLINICAL CHEMISTRY, 2006, 52 (06) : A187 - A187
  • [3] Evaluation of the i-STAT® Portable Clinical Analyzer for the determination of blood creatinine.
    Marver, CL
    Santrach, PJ
    Burritt, MF
    CLINICAL CHEMISTRY, 1999, 45 (06) : A33 - A33
  • [4] A comparative evaluation of calculated eGFR values obtained using the Abbott i-Stat and Beckman Coulter Synchron serum creatinine assays
    Brown, J. Ahmad
    Browning, Conrad
    Wood, Bonnie L.
    Bornhorst, Joshua A.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2008, 130 (03) : 489 - 489
  • [5] Evaluation of the IRMA® SL and i-STAT® systems for whole blood glucose measurements at the point-of-care.
    Kempe, KC
    Chu, C
    Weber, S
    CLINICAL CHEMISTRY, 1999, 45 (06) : A31 - A31
  • [6] Interference on the Abbott i-STAT creatinine assay caused by hydroxyurea
    Paz, Matt Andrew
    Seegmiller, Jesse
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2022, 158 (SUPP 1) : S19 - S20
  • [7] Precision Evaluation of the i-STAT® Glucose Test in the i-STAT G Cartridge using the i-STAT 1 System for Venous, Arterial and Capillary Whole Blood Specimens in Clinical Settings
    Thibodeau, L.
    Aguirre, M. Gonzalez
    Hahn, S.
    Zhang, H.
    CLINICAL CHEMISTRY, 2024, 70 : I129 - I129
  • [8] Evaluation of the portable blood gas analyser i-STAT
    Tschudi, PR
    SCHWEIZER ARCHIV FUR TIERHEILKUNDE, 1998, 140 (12): : 507 - 512
  • [9] Evaluation of the i-STAT Portable Clinical Analyzer in dogs
    Matburger, C
    Henke, J
    Hirschberger, J
    Matburger, S
    Erhardt, W
    TIERARZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2000, 28 (02): : 132 - 137
  • [10] The portable laboratory:: an evaluation of the accuracy and reproducibility of i-STAT©
    Bingham, D
    Kendall, J
    Clancy, M
    ANNALS OF CLINICAL BIOCHEMISTRY, 1999, 36 : 66 - 71