Influence of controlled immediate loading and implant design on peri-implant bone formation

被引:53
|
作者
Vandamme, Katleen
Naert, Ignace
Geris, Liesbet
Vander Sloten, Jozef
Puers, Robert
Duyck, Joke
机构
[1] Katholieke Univ Leuven, Fac Med, Sch Dent Oral Pathol & Maxillofacial Surg, Dept Prosthet Dent,BIOMAT Res Grp, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, Div Biomech & Engn Design, Louvain, Belgium
[3] Katholieke Univ Leuven, Dept Elect Engn, ESAT, MICAS, Louvain, Belgium
关键词
animal; bone chamber; immediate loading; implant macro-design; peri-implant healing;
D O I
10.1111/j.1600-051X.2006.01014.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: Tissue formation at the implant interface is known to be sensitive to mechanical stimuli. The aim of the study was to compare the bone formation around immediately loaded versus unloaded implants in two different implant macro-designs. Material and Methods: A repeated sampling bone chamber with a central implant was installed in the tibia of 10 rabbits. Highly controlled loading experiments were designed for a cylindrical (CL) and screw-shaped (SL) implant, while the unloaded screw-shaped (SU) implant served as a control. An F-statistic model with alpha=5% determined statistical significance. Results: A significantly higher bone area fraction was observed for SL compared with SU (p < 0.0001). The mineralized bone fraction was the highest for SL and significantly different from SU (p < 0.0001). The chance that osteoid- and bone-to-implant contact occurred was the highest for SL and significantly different from SU (p < 0.0001), but not from CL. When bone-to-implant contact was observed, a loading (SL versus SU: p=0.0049) as well as an implant geometry effect (SL versus CL: p=0.01) was found, in favour of the SL condition. Conclusions: Well-controlled immediate implant loading accelerates tissue mineralization at the interface. Adequate bone stimulation via mechanical coupling may account for the larger bone response around the screw-type implant compared with the cylindrical implant.
引用
下载
收藏
页码:172 / 181
页数:10
相关论文
共 50 条
  • [1] Influence of immediate/delayed implant placement and implant platform on the peri-implant bone formation
    Passoni, Bernardo B.
    Marques de Castro, Daniel S.
    de Araujo, Maria Angelica R.
    de Araujo, Carlos d. R. P.
    Piatelli, Adriano
    Benfatti, Cesar A. M.
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (11) : 1376 - 1383
  • [2] Effect of implant surface roughness and loading on peri-implant bone formation
    Vandamme, Katleen
    Naert, Ignace
    Sloten, Jozef Vander
    Puers, Robert
    Duyck, Joke
    JOURNAL OF PERIODONTOLOGY, 2008, 79 (01) : 150 - 157
  • [3] Influence of immediate implant loading on peri-implant soft tissue morphology in the edentulous maxilla
    Gallucci, German O.
    Mavropoulos, Anestis
    Bernard, Jean-Pierre
    Belser, Urs C.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (04) : 595 - 602
  • [4] Influence of peri-implant bone quality on implant stability
    Schiuma, Damiano
    Plecko, Michael
    Kloub, Martin
    Rothstock, Stephan
    Windolf, Markus
    Gueorguiev, Boyko
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (01) : 82 - 87
  • [5] Influence of forces on peri-implant bone
    Isidor, Flemming
    CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 : 8 - 18
  • [6] Peri-implant bone reaction to immediate, early, and delayed orthodontic loading in humans
    Trisi, P
    Rebaudi, A
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2005, 25 (04) : 317 - 329
  • [7] Peri-implant Bone Biomechanics Featuring Short Implant Design
    Hisam, M. J.
    Sharif, S.
    Suhaimi, M. A.
    Kurniawan, D.
    Nor, F. M.
    Shayfull, Z.
    5TH INTERNATIONAL CONFERENCE ON GREEN DESIGN AND MANUFACTURE 2019 (ICONGDM 2019), 2019, 2129
  • [8] The influence of immediate occlusal loading on micro/nano-structure of peri-implant jaw bone in rats
    Yorioka, Hiroaki
    Otsu, Yuto
    Suzuki, Ryu
    Matsunaga, Satoru
    Nakano, Takayoshi
    Abe, Shinichi
    Sasaki, Hodaka
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2024, 10 (01)
  • [9] INFLUENCE OF LOCALLY DELIVERED ZOLEDRONATE ON PERI-IMPLANT BONE RESORPTION AND FORMATION
    Kettenberger, U.
    Ston, J.
    Thein, E.
    Procter, P.
    Pioletti, D. P.
    OSTEOPOROSIS INTERNATIONAL, 2015, 26 : S155 - S156
  • [10] Relationship between magnitude of immediate loading and peri-implant osteogenesis in dogs
    Esaki, Daisuke
    Matsushita, Yasuyuki
    Ayukawa, Yasunori
    Sakai, Nobuo
    Sawae, Yoshinori
    Koyano, Kiyoshi