Real-time RT-PCR quantification of human telomerase reverse transcriptase splice variants in tumor cell lines and non-small cell lung cancer

被引:36
|
作者
Mavrogiannou, Eleni
Strati, Areti
Stathopoulou, Aliki
Tsaroucha, Emily G.
Kaklamanis, Loukas
Lianidoui, Evi S. [1 ]
机构
[1] Univ Athens, Dept Chem, Lab Analyt Chem, GR-15771 Athens, Greece
[2] Sotiria Gen Hosp Chest Dis, Athens, Greece
[3] Onassis Cardiac Surg Ctr, Dept Pathol, Athens, Greece
关键词
D O I
10.1373/clinchem.2006.073015
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: We developed and validated a real-time reverse transcription (RT)-PCR for the quantification of 4 individual human telomerase reverse transcriptase (TERT) splice variants (alpha + beta +, alpha - beta +, alpha + beta -, alpha - beta -) in tumor cell lines and non-small cell lung cancer (NSCLC). Methods: We used in silico designed primers and a common TaqMan probe for highly specific amplification of each TERT splice variant, PCR transcript-specific DNA external standards as calibrators, and the MCF-7 cell line for the development and validation of the method. We then quantified TERT splice variants in 6 tumor cell lines and telomerase activity and TERT splice variant expression in cancerous and paired noncancerous tissue samples from 28 NSCLC patients. Results: In most tumor cell lines, we observed little variation in the proportion of TERT splice variants. The alpha+beta- splice variant showed the highest expression and alpha-beta+ and alpha-beta- the lowest. Quantification of the 4 TERT splice variants in NSCLC and surrounding nonneoplastic tissues showed the highest expression percentage for the alpha+beta- variant in both NSCLC and adjacent nonneoplastic tissue samples, followed by alpha+beta+, with the alpha-beta+ and alpha-beta- splice variants having the lowest expression. In the NSCLC tumors, the alpha+beta+ variant had higher expression than other splice variants, and its expression correlated with telomerase activity, overall survival, and disease-free survival. Conclusions: Real-time RT-PCR quantification is a specific, sensitive, and rapid method that can elucidate the biological role of TERT splice variants in tumor development and progression. Our results suggest that the expression of the TERT alpha+beta+ splice variant may be an independent negative prognostic factor for NSCLC patients. (c) 2007 American Association for Clinical Chemistry
引用
收藏
页码:53 / 61
页数:9
相关论文
共 50 条
  • [1] Real-time RT-PCR quantification of human telomerase reverse transcriptase in breast cancer
    Shaban, H. Abdel Raouf
    Amr, K.
    Afify, M.
    EUROPEAN JOURNAL OF CANCER, 2015, 51 : S299 - S299
  • [2] Development of a quantitative real time RT-PCR for human telomerase reverse transcriptase (hTERT) splice variants
    Mavroyiannou, Eleni
    Stathopoulou, Aliki
    Lianidou, Evi S.
    CANCER RESEARCH, 2006, 66 (08)
  • [3] Quantification of human telomerase reverse transcriptase mRNA in testicular germ cell tumors by quantitative fluorescence real-time RT-PCR
    Schrader, M
    Burger, AM
    Müller, M
    Krause, H
    Straub, B
    Smith, GL
    Newlands, ES
    Miller, K
    ONCOLOGY REPORTS, 2002, 9 (05) : 1097 - 1105
  • [4] Real-time RT-PCR quantification of mature microRNA let-7a expression in non-small cell lung cancer (NSCLC)
    Kosmidou, E.
    Markou, A.
    Tsaroucha, E. G.
    Kaklamanis, L.
    Lianidou, E. S.
    FEBS JOURNAL, 2008, 275 : 154 - 154
  • [5] Real-time PCR quantification of human telomerase reverse transcriptase (hTERT) in colorectal cancer
    Saleh, Said
    Lam, Alfred King-Yin
    Ho, Yik-Hong
    PATHOLOGY, 2008, 40 (01) : 25 - 30
  • [6] PROGNOSTIC VALUE OF HSA-MIR-210 OVEREXPRESSION IN NON-SMALL CELL LUNG CANCER BY QUANTITATIVE REAL-TIME RT-PCR
    Ohsugi, Jun
    Kimura, Yuka
    Watanabe, Yuzuru
    Yamaura, Takumi
    Okabe, Naoyuki
    Yaginuma, Hiroshi
    Hasegawa, Takeo
    Mera, Yoko
    Yonechi, Athushi
    Hoshino, Mika
    Higuchi, Mithunori
    Shio, Yutaka
    Suzuki, Hiroyuki
    Ohishi, Akio
    Goto, Mitukazu
    JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (06) : S590 - S591
  • [7] Detection of circulating cancer cells by real time RT-PCR in the pulmonary vein of patients with non-small cell lung cancer
    Bernaudin, J
    Coulon, S
    Saintigny, P
    Bazelly, B
    Ricci, S
    Barthes, FL
    Milleron, B
    LUNG CANCER, 2005, 49 : S92 - S92
  • [8] Quantification of prolactin receptor mRNA in multiple human tissues and cancer cell lines by real time RT-PCR
    Peirce, SK
    Chen, WY
    JOURNAL OF ENDOCRINOLOGY, 2001, 171 (01) : R1 - R4
  • [9] Expression of human telomerase reverse transcriptase splice variants is well correlated with low telomerase activity in osteosarcoma cell lines
    Fujiwara-Akita, H
    Maesawa, C
    Honda, T
    Kobayashi, S
    Masuda, T
    INTERNATIONAL JOURNAL OF ONCOLOGY, 2005, 26 (04) : 1009 - 1016
  • [10] REAL-TIME PCR QUANTIFICATION OF PLASMA DNA IN NON-SMALL CELL LUNG CANCER PATIENTS AND HEALTHY CONTROLS
    Szpechcinski, A.
    Dancewicz, M.
    Kopinski, P.
    Kowalewski, J.
    Chorostowska-Wynimko, J.
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2009, 14 : 237 - 240